TeSys D Time delay Auxiliary Contact Block TeSys Deca, 1NO + 1NC, on delay 10-180s, front, screw clamp terminals
Item Number: LADT4
TeSys Deca time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD. It provides 1NO+1NC contacts rated up to 10A 690V AC, On-delay setting range 10-180s, connection by screw clamp terminals. Clip-on front mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC),
Datasheet
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| - | |||
| - | |||
| - |
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| 1 | CAR | 3389110385977 | - |
| 10 | PAC | 53389110385972 | - |
Specifications
Design
| Range |
|
|---|---|
| Range of product |
|
| Product or component type | time delay auxiliary contact block |
Physical
| Range compatibility |
|
|---|---|
| [ue] rated operational voltage | 690 V AC 25...400 Hz |
| [ie] rated operational current |
|
| Standards |
|
| Product certifications |
|
| Protection type | gG fuse 10 A |
| Mechanical durability | 5 Mcycles |
| Insulation resistance | > 10 MOhm |
| Connections - terminals |
|
| Height | 48 mm |
| Width | 44 mm |
| Depth | 61 mm |
| Environmental characteristic | normal environment |
| Ip degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for storage | -60...80 °C |
| Ambient air temperature for operation | -40...70 °C |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP110702EN |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | Product out of China RoHS scope |
| Eu rohs directive | Compliant By Exemption |
| California proposition 65 | WARNING: Cancer - www.P65Warnings.ca.gov |
Others
| Life cycle assessment data | Yes |
|---|---|
| Substance regulation data deliverable | Yes |
| Average percentage of recycled plastic content | 0 % |
| Package 1 bare product quantity | 1 |
| Legacy weee scope | In |
| At least in Europe | |
| Warranty duration(in months) bmecat | 18 |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Product name | TeSys Deca |
| Mounting location | front |
| Pole contact composition | 1 NO + 1 NC |
| Auxiliary contacts operation | time delay |
| Timer type | on delay |
| Time delay range | 10...180 s |
| [ui] rated insulation voltage |
|
| [ith] conventional free air thermal current | 10 A (at 60 °C) |
| Irms rated making capacity |
|
| Permissible short-time rating |
|
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time |
|
| Tightening torque |
|
| Shielding continuity terminal | without |
| Protective treatment | TH conforming to IEC 60068 |
| Operating altitude | 3000 m |
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 5.2 cm |
| Package 1 width | 6.5 cm |
| Package 1 length | 5.0 cm |
| Package 1 weight | 74.0 g |
| Unit type of package 2 | BB1 |
| Number of units in package 2 | 10 |
| Package 2 height | 5.2 cm |
| Package 2 width | 14.0 cm |
| Package 2 length | 24.0 cm |
| Package 2 weight | 750.0 g |
| Unit type of package 3 | S03 |
| Number of units in package 3 | 140 |
| Package 3 height | 30.0 cm |
| Package 3 width | 30.0 cm |
| Package 3 length | 40.0 cm |
| Package 3 weight | 10.988 kg |
| Total lifecycle carbon footprint | 4 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] | 0.49343699637388094 |
| Carbon footprint of the manufacturing phase [a1 to a3] | 0.5 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] | 0.01994433894775979 |
| Carbon footprint of the distribution phase [a4] | 0 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] | 0.01152272562406154 |
| Carbon footprint of the installation phase [a5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 3.1606 |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 3 kg CO2 eq. |
| Sustainable packaging | Yes |
| Carbon footprint of the end-of-life phase [c1 to c4] | 0.17376341204753004 |
| Carbon footprint of the end-of-life phase [c1 to c4] | 0.2 kg CO2 eq. |
| Pvc free | Yes |
| F-gas free | N/A |
| Take-back | No |
| Product contributes to saved and avoided emissions | No |
| Removable battery | N/A |
| Total lifecycle carbon footprint | 3.8592674729932326 |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | Yes |
| Scip number | 116c8fe4-0538-43fb-9c58-cfc8259b5fbc |
| China rohs label | 3 |
| Pvc free | Yes |
| End of life manual availability | N/A |
| Take-back | No |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) | 18 |
Documents & downloads
-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Installation Instruction
-
Technical Drawing
-
Certificates (MSDS)
-
Declaration of Conformity
-
eTechPub
-
Declaration of Conformity (Sustainability)
Technical drawing for LADT4_CAD_DOC
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
LADT4_2DSalesDrawing_PDF
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
Auxiliary Time Delay Block D-Line TESYS Technical drawings
VERSION
1.0
DATE
02 Aug 2022
REVISION
1.0
CCC_TeSys Deca_LADR, LADS, LADT, LAETSD
VERSION
1.0
DATE
12 Dec 2024
REVISION
1.0
DNV Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
EU RO MR Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
CB Certificate TeSys D -LAD-R-S-T_LAETSD_Chasseneuil
VERSION
1.0
DATE
03 Apr 2023
REVISION
1.0
UL Certificate E164353 NKCR Auxiliary Devices
VERSION
1.0
DATE
06 Oct 2022
REVISION
1.0
CSA Certificate_ TeSys D_LADT_LADR_LADS
VERSION
1.0
DATE
06 Oct 2022
REVISION
1.0
LADT4 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LADT4 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LADT4 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LADT4 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LADT4 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LADT4 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LADT4 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LADT4 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LADT4 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LADT4 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LADT4 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LADT4 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
Related products
DISCONTINUED
CAD32BD
TeSys K Control Relay
3NO+2NC, 0 to 690V, 24VDC standard coil, screw clamp
DISCONTINUED
CAD32M7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 220VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
CAD32F7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 110VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
CAD32E7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 48VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
CAD50BD
TeSys K Control Relay
5NO, 0 to 690V, 24VDC standard coil, screw clamp
DISCONTINUED
CAD32FD
TeSys K Control Relay
3NO+2NC, 0 to 690V, 110VDC standard coil, screw clamp
DISCONTINUED
CAD50F7
TeSys D Control Relay
5 NO, <= 690V, 110VAC, Standard Coil
DISCONTINUED
CAD32B7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 24VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
CAD50M7
TeSys D Control Relay
5 NO, <= 690V, 220VAC, Standard Coil
DISCONTINUED
CAD32G7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 120VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
CAD32MD
TeSys K Control Relay
3NO+2NC, 0 to 690V, 220VDC standard coil, screw clamp
DISCONTINUED
CAD32GD
TeSys K Control Relay
3NO+2NC, 0 to 690V, 125VDC standard coil, screw clamp
DISCONTINUED
CAD32BD
TeSys K Control Relay
3NO+2NC, 0 to 690V, 24VDC standard coil, screw clamp
DISCONTINUED
CAD32M7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 220VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
CAD32F7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 110VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
CAD32E7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 48VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
CAD50BD
TeSys K Control Relay
5NO, 0 to 690V, 24VDC standard coil, screw clamp
DISCONTINUED
CAD32FD
TeSys K Control Relay
3NO+2NC, 0 to 690V, 110VDC standard coil, screw clamp
DISCONTINUED
CAD32B7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 24VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
CAD32G7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 120VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
CAD32MD
TeSys K Control Relay
3NO+2NC, 0 to 690V, 220VDC standard coil, screw clamp
DISCONTINUED
CAD32GD
TeSys K Control Relay
3NO+2NC, 0 to 690V, 125VDC standard coil, screw clamp
Recently viewed
DISCONTINUED
LADT4
TeSys D Time delay Auxiliary Contact Block
TeSys Deca, 1NO + 1NC, on delay 10-180s, front, screw clamp terminals
DISCONTINUED
GV2L05
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 1A, magnetic, rotary handle, screw clamp terminals
DISCONTINUED
LP1D80008FW
TeSys D Contactor
TeSys Deca, 4P(2NO + 2NC), AC-1, <= 440 V 125 A - 110 V DC coil
DISCONTINUED
LADT4
TeSys D Time delay Auxiliary Contact Block
TeSys Deca, 1NO + 1NC, on delay 10-180s, front, screw clamp terminals
DISCONTINUED
GV2L05
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 1A, magnetic, rotary handle, screw clamp terminals
DISCONTINUED
LP1D80008FW
TeSys D Contactor
TeSys Deca, 4P(2NO + 2NC), AC-1, <= 440 V 125 A - 110 V DC coil