Browse all
Browse all

TeSys D Contactor TeSys Deca, 4P(2NO + 2NC), AC-1, <= 440 V 125 A - 110 V DC coil

TeSys D Contactor TeSys Deca, 4P(2NO + 2NC), AC-1, <= 440 V 125 A - 110 V DC coil

Item Number: LP1D80008FW

Datasheet

Product Dimensions

Width icon

Width96 mm

Height icon

Height127 mm

Depth icon

Depth196 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range TeSys
Range of product TeSys Deca
Product or component type contactor
Warranty 18 months

Physical

[ue] rated operational voltage
  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
[ie] rated operational current 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Mechanical durability 4 Mcycles
Electrical durability 0.8 Mcycles 125 A AC-1 at Ue <= 440 V
Connections - terminals
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid
  • power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end
  • power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end
  • power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end
  • power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end
  • power circuit: connector 1 4-50 mm² - cable stiffness: solid
  • power circuit: connector 2 4-25 mm² - cable stiffness: solid
  • control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end
Mounting support
  • plate
  • rail
Standards
  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 508
Product certifications
  • BV
  • CCC
  • CSA
  • DNV
  • EAC
  • GL
  • LROS (Lloyds register of shipping)
  • UL
Ip degree of protection IP20 front face conforming to IEC 60529
Height 127 mm
Width 96 mm
Depth 196 mm
Net weight 2.91 kg
Reach free of svhc Yes
Toxic heavy metal free Yes
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP110205EN
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant

Others

Legacy weee scope In
Warranty duration(in months) bmecat 18
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
At least in Europe
Device short name LP1D
Contactor application resistive load
Utilisation category AC-1
Poles description 4P
[uc] control circuit voltage 110 V DC
Compatibility code LP1D
Pole contact composition 2 NO + 2 NC
Contact compatibility M4
Protective cover without
[ith] conventional free air thermal current 125 A (at 60 °C) for power circuit
Irms rated making capacity 1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current
  • 135 A 40 °C - 10 min for power circuit
  • 320 A 40 °C - 1 min for power circuit
  • 640 A 40 °C - 10 s for power circuit
  • 990 A 40 °C - 1 s for power circuit
Associated fuse rating
  • 200 A gG at <= 690 V coordination type 1 for power circuit
  • 160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole 12.5 W AC-1
[ui] rated insulation voltage
  • power circuit: 600 V CSA certified
  • power circuit: 600 V UL certified
  • power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level
  • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Control circuit type DC wide range
Coil technology without built-in suppressor module
Control circuit voltage limits
  • 0.1...0.3 Uc (-40-70 °C):drop-out DC
  • 0.75...1.2 Uc (-40-55 °C):operational DC
  • 1...1.2 Uc (55-70 °C):operational DC
Inrush power in w 22 W (at 20 °C)
Hold-in power consumption in w 22 W at 20 °C
Operating time
  • 6...20 ms opening
  • 20...35 ms closing
Time constant 75 ms
Tightening torque
  • control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
  • power circuit: 12 N.m - on connector hexagonal screw head 4 mm
Permissible ambient air temperature around the device
  • -40...60 °C
  • 60...70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness
  • vibrations contactor open (2 Gn, 5...300 Hz)
  • vibrations contactor closed (3 Gn, 5...300 Hz)
  • shocks contactor open (8 Gn for 11 ms)
  • shocks contactor closed (10 Gn for 11 ms)
Unit type of package 1 PCE
Number of units in package 1 1
Sustainable packaging No
Pvc free Yes
China rohs label 1
Pvc free Yes
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.