Specifications
Design
| Range of product | Altivar 12 |
|---|---|
| Product or component type | variable speed drive |
| Warranty | 18 months |
Physical
| Mounting mode | cabinet mount |
|---|---|
| Communication port protocol | Modbus |
| Ip degree of protection | IP20 |
| Connector type | 1 RJ45 |
| Protection type |
|
| Quantity per set | set of 1 |
| Width | 105 mm |
| Height | 142 mm |
| Depth | 156.2 mm |
| Net weight | 1.4 kg |
| Product certifications |
|
| Marking | CE |
| Standards |
|
| Relative humidity |
|
| Ambient air temperature for operation |
|
| Ambient air temperature for storage | -25...70 °C |
| Ambient air temperature for operation | -10...60 °C |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP090202EN |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | X |
| Eu rohs directive | Compliant By Exemption |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Others
| Life cycle assessment data | No |
|---|---|
| If one of the deliverables is not relevant please give the reason | End of commercialization (planned, announced or effective) |
| Substance regulation data deliverable | Yes |
| Legacy weee scope | In |
| Package 1 bare product quantity | 1 |
| Package 2 bare product quantity | 30 |
| Average percentage of recycled plastic content | 0 % |
| At least in Europe | |
| Warranty duration(in months) bmecat | 18 |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Product specific application | simple machine |
| Design of frequency changer | U converter |
| Supply frequency | 50/60 Hz +/- 5 % |
| [us] rated supply voltage | 200...240 V - 15...10 % |
| [us] rated supply voltage | 200...240 V |
| Relative symmetric mains voltage tolerance | 10 % |
| Nominal output current | 10 A |
| Number of input phases | 3 |
| Number of output phases | 3 |
| Motor power kw | 2.2 kW |
| Motor power hp | 3 hp |
| Emc filter | integrated |
| Network number of phases | 1 phase |
| Motor power hp | 3 hp |
| Discrete input number | 4 |
| Discrete output number | 2 |
| Analogue input number | 1 |
| Analogue output number | 1 |
| Relay output number | 1 |
| Number of inputs, bidirectional, not potential-free | 0 |
| Number of inputs, potential-free | 0 |
| Computer port | true |
| Optical interface present | false |
| Physical interface | 2-wire RS 485 |
| Continuous output current | 10 A at 4 kHz |
| Method of access | server Modbus serial |
| Speed drive output frequency | 0.5...400 Hz |
| Speed range | 1...20 |
| Sampling duration |
|
| Linearity error | +/- 0.3 % of maximum value for analogue input |
| Frequency resolution |
|
| Time constant | 20 ms +/- 1 ms for reference change |
| Transmission rate |
|
| Transmission frame | RTU |
| Number of addresses | 1...247 |
| Data format | 8 bits, configurable odd, even or no parity |
| Communication service |
|
| Type of polarization | no impedance |
| Number of hw interfaces parallel | 0 |
| Number of hw interfaces industrial ethernet | 0 |
| Number of hw interfaces profinet | 0 |
| Number of hw interfaces serial rs232 | 0 |
| Number of hw interfaces serial rs422 | 0 |
| Number of hw interfaces serial rs485 | 1 |
| Number of hw interfaces serial tty | 0 |
| Number of hw interfaces usb | 0 |
| Number of hw interfaces other | 0 |
| Supporting protocol for as-interface safety at work | false |
| Supporting protocol for asi | false |
| Supporting protocol for suconet | false |
| Supporting protocol for bacnet | false |
| Supporting protocol for can | false |
| Supporting protocol for data-highway | false |
| Supporting protocol for devicenet | false |
| Supporting protocol for devicenet safety | false |
| Supporting protocol for ethernet/ip | false |
| Supporting protocol for foundation fieldbus | false |
| Supporting protocol for interbus | false |
| Supporting protocol for interbus-safety | false |
| Supporting protocol for knx | false |
| Supporting protocol for lon | false |
| Supporting protocol for modbus | true |
| Supporting protocol for other bus systems | false |
| Supporting protocol for profibus | false |
| Supporting protocol for profinet cba | false |
| Supporting protocol for profinet io | false |
| Supporting protocol for profisafe | false |
| Supporting protocol for safetybus p | false |
| Supporting protocol for sercos | false |
| Supporting protocol for tcp/ip | false |
| 4 quadrant operation possible | false |
| Asynchronous motor control profile |
|
| Maximum output frequency | 4 kHz |
| Transient overtorque | 150...170 % of nominal motor torque depending on drive rating and type of motor |
| Acceleration and deceleration ramps |
|
| Motor slip compensation |
|
| Switching frequency |
|
| Nominal switching frequency | 4 kHz |
| Braking to standstill | by DC injection |
| Brake chopper integrated | false |
| Maximum associated fuse rating | 12.5 A |
| Line current |
|
| Maximum output voltage | 240 V |
| Nominal output power | 2200.0 W |
| Apparent power | 4.8 kVA at 240 V (heavy duty) |
| Maximum transient current |
|
| Capacity of dc link | 1890.0 µF |
| Network frequency | 50...60 Hz |
| Relative symmetric network frequency tolerance | 5 % |
| Prospective line isc | 1 kA |
| 1 phase low current possible | false |
| Base load current at high overload | 10.0 A |
| Application in domestic and commercial area permitted | false |
| Application in industrial area permitted | true |
| Emc limit value (complied) | true |
| Power loss per device current dependent | 93.0 W |
| Power loss static current independent | 11.0 W |
| Power dissipation in w | forced cooling: 93.0 W |
| Housing material | plastic |
| With safety function safely limited speed (sls) | false |
| With safety function safe brake management (sbc/sbt) | false |
| With safety function safe operating stop (sos) | false |
| With safety function safe position (sp) | false |
| With safety function safe programmable logic | false |
| With safety function safe speed monitor (ssm) | false |
| With safety function safe stop 1 (ss1) | false |
| With sft fct safe stop 2 (ss2) | false |
| With safety function safe torque off (sto) | false |
| With safety function safely limited position (slp) | false |
| With safety function safe direction (sdi) | false |
| Operating element present | true |
| Tightening torque | 1.2 N.m |
| Insulation | electrical between power and control |
| Operating altitude |
|
| Operating position | vertical +/- 10 degree |
| Assembly style | with heat sink |
| Electromagnetic compatibility |
|
| Environmental class (during operation) |
|
| Environmental class (during storage) |
|
| Environmental class (during transport) |
|
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Maximum acceleration under shock load (during storage) | 150 m/s² at 11 ms |
| Maximum acceleration under shock load (during transport) | 150 m/s² at 11 ms |
| Maximum acceleration under vibratory load (during storage) | 10 m/s² at 13...200 Hz |
| Maximum acceleration under vibratory load (during transport) | 10 m/s² at 13...200 Hz |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Maximum deflection under vibratory load (during storage) | 1.5 mm at 2...13 Hz |
| Maximum deflection under vibratory load (during transport) | 1.5 mm at 2...13 Hz |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
| Volume of cooling air | 16 m3/h |
| Overvoltage category | class III |
| Regulation loop | adjustable PID regulator |
| Electromagnetic emission |
|
| Vibration resistance |
|
| Shock resistance | 15 gn conforming to IEC 60068-2-27 for 11 ms |
| Noise level | 45 dB |
| Pollution degree | 2 |
| Ambient air transport temperature | -25...70 °C |
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 18.000 cm |
| Package 1 width | 18.500 cm |
| Package 1 length | 18.500 cm |
| Package 1 weight | 1.767 kg |
| Unit type of package 2 | S06 |
| Number of units in package 2 | 30 |
| Package 2 height | 75.000 cm |
| Package 2 width | 60.000 cm |
| Package 2 length | 80.000 cm |
| Package 2 weight | 65.950 kg |
| Green premium status for reporting | Green Premium product |
| Sustainable packaging | Yes |
| Take-back | No |
| Product contributes to saved and avoided emissions | Yes |
| Removable battery | N/A |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | Yes |
| Scip number | 4a84ec00-b29e-4a08-82b9-8e16a72fb187 |
| China rohs label | 5 |
| Product contributes to saved and avoided emissions | Yes |
| End of life manual availability | ENVEOLI100204EN |
| Take-back | No |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) | 18 |
Documents & downloads
-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Installation Instruction
-
Operating Manuals
-
eTechPub
-
Declaration of Conformity
-
Certificates (MSDS)
-
Declaration of Conformity (Sustainability)
-
Software - Data Library
ATV12 Quick Start annex - SCCR
VERSION
5.0
DATE
27 Feb 2026
REVISION
5.0
Instruction sheet - Braking Resistor: VW3A7723, VW3A7724, VW3A7725
VERSION
2.0
DATE
23 Jun 2025
REVISION
2.0
Instruction sheet Fan kit: VZ3V1301,302
VERSION
1.0
DATE
12 Dec 2023
REVISION
1.0
1) ATV12 Getting Started
VERSION
3.0
DATE
25 May 2023
REVISION
3.0
ATV12 Variable Speed Drives Extended Short Circuit Ratings - Instructions
VERSION
1.0
DATE
25 May 2023
REVISION
1.0
Instruction sheet - substitution ATV11-ATV12
VERSION
1.1
DATE
02 Aug 2022
REVISION
1.1
ATV12HU22M2 China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATV12HU22M2 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
Related products
DISCONTINUED
GV2ME32
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 24 to 32A, thermal magnetic, screw clamp terminals, button control
DISCONTINUED
LC1D25P7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 230VAC 50/60Hz coil
DISCONTINUED
LC1D25B7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 24VAC 50/60Hz coil
DISCONTINUED
LC1D25E7
TeSys D Contactor
3P(3NO), AC-3/AC-3e, <=440V 25A, 48V AC coil
DISCONTINUED
LC1D25F7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 110VAC 50/60Hz coil
DISCONTINUED
LC1D25M7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 220VAC 50/60Hz coil
DISCONTINUED
LC1D25BD
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 24VDC coil
DISCONTINUED
LC1D25ED
TeSys D Contactor
3P(3 NO), AC-3/AC-3e,L1766:L1787 0 to 440V, 25A, 48VDC coil
DISCONTINUED
LC1D25BL
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 24VDC low consumption coil
DISCONTINUED
GV2ME32
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 24 to 32A, thermal magnetic, screw clamp terminals, button control
DISCONTINUED
LC1D25P7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 230VAC 50/60Hz coil
DISCONTINUED
LC1D25B7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 24VAC 50/60Hz coil
DISCONTINUED
LC1D25F7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 110VAC 50/60Hz coil
DISCONTINUED
LC1D25M7
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 220VAC 50/60Hz coil
DISCONTINUED
LC1D25ED
TeSys D Contactor
3P(3 NO), AC-3/AC-3e,L1766:L1787 0 to 440V, 25A, 48VDC coil
DISCONTINUED
LC1D25BL
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 24VDC low consumption coil
Recently viewed
DISCONTINUED
ATV12HU22M2
Altivar 12 Variable speed drive ATV12
2.2kW, 3hp, 200..240V, 1ph, with heat sink