TeSys Mini-Vario TeSys Vario enclosed emergency switch disconnector, 100A, IP65, long handle

Home ProductsIndustrialTeSysTeSys Vario enclosed

TeSys Mini-Vario TeSys Vario enclosed emergency switch disconnector, 100A, IP65, long handle

Item Number: VCF5GEN

Datasheet

Product Dimensions

Width icon

Width241 mm

Height icon

Height291 mm

Depth icon

Depth191 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Product or component type

enclosed emergency stop switch disconnector

Warranty

18 months

Physical

Control type

rotary handle

Marking

0 - 1

[ue] rated operational voltage

690 V AC

[ie] rated operational current

68.5 A (AC-23A) at 400 V

Mechanical durability

30000 cycles

Electrical durability

  • 30000 cycles AC-21
  • 30000 cycles DC-1...5

Environmental characteristic

standard environment

Connections - terminals

  • screw clamp terminals70-70 mm² - flexible - with cable end
  • screw clamp terminals95-95 mm² - solid

Height

291 mm

Width

241 mm

Depth

191 mm

Net weight

2.19 kg

Standards

  • IEC 60947-4-1
  • IEC 60204

Ip degree of protection

IP65 conforming to IEC 60529

Ambient air temperature for operation

-20...50 °C

Toxic heavy metal free

Yes

Mercury free

Yes

Rohs exemption information

Yes

Environmental disclosure

ENVPEP2211019

Eu rohs directive

Compliant with Exemptions

Reach regulation

Reference contains Substances of Very High Concern above the threshold

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Others

Life cycle assessment data

Yes

Substance regulation data deliverable

Yes

Legacy weee scope

In

Average percentage of recycled plastic content

0 %

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Package 1 bare product quantity

1

At least in Europe

Product name

TeSys VARIO

Device short name

VCF

Performance level

high performance

Poles description

3P

Type of operator

long handle

Handle colour

red

Handle front plate colour

yellow

Rotary handle padlocking

1 to 3 padlocks 4-8 mm

[uimp] rated impulse withstand voltage

8 kV

[ithe] conventional enclosed thermal current

100 A

Rated operational power in w

  • 37 kW at 400 V (AC-23)
  • 30 kW at 400 V (AC-3)

Intermittent duty class

30

Making capacity

  • 1250 A at 400 V AC-21A
  • 1250 A at 400 V AC-22A
  • 1250 A at 400 V AC-23A

[icm] rated short-circuit making capacity

2.8 kA at 400 V at Ipeak

[icw] rated short-time withstand current

1500 A at 400 V duration: 1 s

Rated conditional short-circuit current

  • 10 kA at 400 V - associated fuse 125 A aM
  • 10 kA at 400 V - associated fuse 125 A gG

Breaking capacity

  • 1000 A at 400 V (AC-21A)
  • 1000 A at 400 V (AC-22A)
  • 1000 A at 400 V (AC-23A)

Suitability for isolation

yes

Tightening torque

22.6...22.6 N.m - on screw clamp terminals

Fire resistance

960 °C conforming to IEC 60595-2-1

Base dimension

90 x 90 mm

Compatibility code

enclosed switch disconnector

Protective treatment

TC

Mechanical robustness

  • vibrations 10...150 Hz (1 gn) conforming to IEC 60068-2-6
  • shocks 11 ms (30 Gn) conforming to IEC 60068-2-27

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

30.000 cm

Package 1 width

25.000 cm

Package 1 length

20.000 cm

Package 1 weight

2.897 kg

Unit type of package 2

S04

Number of units in package 2

2

Package 2 height

30.000 cm

Package 2 width

40.000 cm

Package 2 length

60.000 cm

Package 2 weight

6.522 kg

Unit type of package 3

P06

Number of units in package 3

8

Package 3 height

75.000 cm

Package 3 width

60.000 cm

Package 3 length

80.000 cm

Package 3 weight

38.372 kg

Green premium status for reporting

Green Premium product

Total lifecycle carbon footprint

36 kg CO2 eq.

Carbon footprint of the manufacturing phase [a1 to a3]

15.237546554734571

Carbon footprint of the manufacturing phase [a1 to a3]

15 kg CO2 eq.

Carbon footprint of the distribution phase [a4]

0.5645290261022665

Carbon footprint of the distribution phase [a4]

0.6 kg CO2 eq.

Carbon footprint of the installation phase [a5]

0.4581174955159203

Carbon footprint of the installation phase [a5]

0.5 kg CO2 eq.

Carbon footprint of the use phase [b2, b3, b4, b6]

13.432378470046519

Carbon footprint of the use phase [b2, b3, b4, b6]

13 kg CO2 eq.

Sustainable packaging

Yes

Carbon footprint of the end-of-life phase [c1 to c4]

6.33881332710092

Carbon footprint of the end-of-life phase [c1 to c4]

6 kg CO2 eq.

F-gas free

N/A

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Total lifecycle carbon footprint

36.0313848735002

Average percentage of recycled metal content

0 %

Packaging made with recycled cardboard

Yes

Packaging without single use plastic

Yes

Scip number

9ea58720-3cf9-4883-9af8-9d64d3981af2

End of life manual availability

N/A

Take-back

No

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Warranty (in months)

18
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Environmental Disclosure

  • Installation Instruction

  • Technical illustration

  • Declaration of Conformity

  • Certificates (MSDS)

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.