TeSys D Star Delta Starter TeSys Deca, 3 x 3P (3 NO), 32A, 110VAC 50/60Hz coil

Home ProductsIndustrialTeSysStar Delta Starter

TeSys D Star Delta Starter TeSys Deca, 3 x 3P (3 NO), 32A, 110VAC 50/60Hz coil

Item Number: LC3D32AF7

Datasheet

Product Dimensions

Width icon

Width166 mm

Height icon

Height124 mm

Depth icon

Depth149 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product TeSys Deca
Range
  • TeSys
  • TeSys Deca
Product or component type star delta starter
Warranty 18 months

Physical

Device presentation pre-wired
[ue] rated operational voltage power circuit: <= 690 V AC 25...400 Hz
[ie] rated operational current 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
Electrical durability 1.65 Mcycles 32 A AC-3 at Ue <= 440 V
Provided equipment protective cover
Mounting support plate
Standards
  • EN 60947-5-1
  • EN 60947-4-1
  • UL 508
  • CSA C22.2 No 14
  • IEC 60947-4-1
  • IEC 60947-5-1
  • IEC 60335-1
Product certifications
  • RINA
  • GL
  • GOST
  • BV
  • DNV
  • CCC
  • CSA
  • LROS (Lloyds register of shipping)
  • UL
Connections - terminals
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
  • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
  • power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end
  • power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end
  • power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end
  • power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end
  • power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid without cable end
  • power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid without cable end
Mechanical durability 15 Mcycles
Width 166 mm
Height 124 mm
Depth 149 mm
Net weight 2.03 kg
Insulation resistance > 10 MOhm for signalling circuit
Ip degree of protection IP20 front face conforming to IEC 60529
Climatic withstand
  • conforming to IACS E10
  • conforming to IEC 60947-1 Annex Q category D
Ambient air temperature for storage -60...80 °C
Ambient air temperature for operation -40...70 °C at Uc
Reach free of svhc Yes
Toxic heavy metal free Yes
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP1102029EN
Reach regulation Free of Substances of Very High Concern above the threshold
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant
California proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Others

Life cycle assessment data Yes
Substance regulation data deliverable Yes
Average percentage of recycled plastic content 0 %
Package 1 bare product quantity 1
Legacy weee scope In
At least in Europe
Warranty duration(in months) bmecat 18
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Product name TeSys Deca
Device short name LC3D
Contactor application motor control
Utilisation category AC-3
Poles description 3 x 3P
Pole contact composition 3 x 3 NO
Motor power kw
  • 15 kW at 220/230 V AC 50/60 Hz
  • 25 kW at 380/400 V AC 50/60 Hz
  • 30 kW at 415 V AC 50/60 Hz
  • 30 kW at 440 V AC 50/60 Hz
Control circuit type AC at 50/60 Hz
[uc] control circuit voltage 110 V AC 50/60 Hz
Auxiliary contact composition 1 NC for KM1 star contactor
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Overvoltage category III
[ui] rated insulation voltage
  • power circuit: 690 V conforming to IEC 60947-4-1
  • power circuit: 600 V CSA certified
  • power circuit: 600 V UL certified
  • signalling circuit: 690 V conforming to IEC 60947-1
  • signalling circuit: 600 V CSA certified
  • signalling circuit: 600 V UL certified
Interlocking type mechanical
Tightening torque
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Maximum operating rate 30 cyc/h 60 °C
Starting time 30 s
Coil technology without built-in suppressor module
Control circuit voltage limits
  • drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C)
  • operational: 0.8...1.1 Uc at 50 Hz (at <60 °C)
  • operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
Inrush power in va
  • 70 VA 60 Hz cos phi 0.75 (at 20 °C)
  • 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in va
  • 7.5...7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
  • 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2...3 W at 50/60 Hz
Auxiliary contacts type
  • mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC
  • mirror contact conforming to IEC 60947-4-1 3 x 1 NC
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA for signalling circuit
Switching voltage 17 V for signalling circuit
Non-overlap time
  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact
Power range
  • 15...25 kW at 380...440 V 3 phases
  • 15...25 kW at 200...240 V 3 phases
  • 30...50 kW at 380...440 V 3 phases
Motor starter type star delta starter
Contactor coil voltage 110 V AC standard
Protective treatment TH conforming to IEC 60068-2-30
Pollution degree 3
Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness
  • vibrations contactor open: 2 Gn, 5...300 Hz
  • vibrations contactor closed: 4 Gn, 5...300 Hz
  • shocks contactor closed: 15 Gn for 11 ms
  • shocks contactor open: 8 Gn for 11 ms
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 16.100 cm
Package 1 width 17.800 cm
Package 1 length 23.500 cm
Package 1 weight 1.712 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 449 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 12.478721147929194
Carbon footprint of the manufacturing phase [a1 to a3] 12 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.9421208150880356
Carbon footprint of the distribution phase [a4] 0.9 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 430.85202279426505
Carbon footprint of the use phase [b2, b3, b4, b6] 431 kg CO2 eq.
Sustainable packaging Yes
Carbon footprint of the end-of-life phase [c1 to c4] 4.930304013892409
Carbon footprint of the end-of-life phase [c1 to c4] 5 kg CO2 eq.
Pvc free Yes
F-gas free N/A
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 449.20316877117466
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
China rohs label 1
Pvc free Yes
End of life manual availability ENVEOLI110229EN
Take-back No
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Environmental Disclosure

  • End of Life Manual

  • Installation Instruction

  • eTechPub

  • Declaration of Conformity

  • Certificates (MSDS)

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.