| Life cycle assessment data |
Yes |
| Substance regulation data deliverable |
Yes |
| Package 1 bare product quantity |
1 |
| Legacy weee scope |
In |
| |
At least in Europe |
| Package 2 bare product quantity |
4 |
| Average percentage of recycled plastic content |
0 % |
| Warranty duration(in months) bmecat |
18 |
| Weee label |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Product name |
TeSys Deca Advanced |
| Device short name |
LC2D |
| Contactor application |
- resistive load
- motor control
|
| Utilisation category |
|
| Poles description |
3P |
| Pole contact composition |
3 NO |
| Motor power kw |
- 15 kW at 220...230 V AC 50 Hz
- 22 kW at 380...400 V AC 50 Hz
- 25 kW at 415 V AC 50 Hz
- 30 kW at 440 V AC 50 Hz
- 30 kW at 500 V AC 50 Hz
- 33 kW at 660...690 V AC 50 Hz
|
| Motor power hp |
- 3 hp at 115 V AC 60 Hz for 1 phase motors
- 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
- 15 hp at 200/208 V AC 60 Hz for 3 phases motors
- 15 hp at 230/240 V AC 60 Hz for 3 phases motors
- 40 hp at 460/480 V AC 60 Hz for 3 phases motors
- 40 hp at 575/600 V AC 60 Hz for 3 phases motors
|
| Control circuit type |
- AC at 50/60 Hz AC/DC electronic
- DC AC/DC electronic
|
| [uc] control circuit voltage |
- 100...250 V AC 50/60 Hz
- 100...250 V DC
|
| Auxiliary contact composition |
1 NO + 1 NC |
| [uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947 |
| Overvoltage category |
III |
| [ith] conventional free air thermal current |
- 10 A (at 60 °C) for signalling circuit
- 80 A (at 60 °C) for power circuit
|
| Irms rated making capacity |
- 140 A AC for signalling circuit conforming to IEC 60947-5-1
- 250 A DC for signalling circuit conforming to IEC 60947-5-1
- 900 A at 440 V for power circuit conforming to IEC 60947
|
| Rated breaking capacity |
900 A at 440 V for power circuit conforming to IEC 60947 |
| [icw] rated short-time withstand current |
- 100 A - 1 s for signalling circuit
- 120 A - 500 ms for signalling circuit
- 140 A - 100 ms for signalling circuit
- 400 A 40 °C - 10 s for power circuit
- 810 A 40 °C - 1 s for power circuit
- 84 A 40 °C - 10 min for power circuit
- 208 A 40 °C - 1 min for power circuit
|
| Associated fuse rating |
- 10 A gG for signalling circuit conforming to IEC 60947-5-1
- 100 A gG at <= 690 V coordination type 1 for power circuit
- 100 A gG at <= 690 V coordination type 2 for power circuit
|
| Average impedance |
1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| [ui] rated insulation voltage |
- power circuit: 690 V conforming to IEC 60947-4-1
- signalling circuit: 690 V conforming to IEC 60947-1
|
| Power dissipation per pole |
|
| Protective cover |
with |
| Interlocking type |
mechanical |
| Tightening torque |
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
- power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm
- power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm
|
| Safety reliability level |
- B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
- B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
|
| Maximum operating rate |
3600 cyc/h 60 °C |
| Coil technology |
built-in bidirectional peak limiting |
| Control circuit voltage limits |
- <= 0.1 Uc (-40-70 °C):drop-out AC/DC
- 0.85...1.1 Uc (-40-60 °C):operational AC/DC
- 1...1.1 Uc (60-70 °C):operational AC/DC
|
| Auxiliary contacts type |
- type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
- type mirror contact 1 NC conforming to IEC 60947-4-1
|
| Signalling circuit frequency |
25...400 Hz |
| Minimum switching current |
5 mA for signalling circuit |
| Minimum switching voltage |
17 V for signalling circuit |
| Non-overlap time |
- 1.5 ms on de-energisation between NC and NO contact
- 1.5 ms on energisation between NC and NO contact
|
| Compatibility code |
LC2D |
| [uc] control circuit voltage |
100...250 V |
| Rated thermal current (ith) |
80 A |
| Maximum motor phase current |
50 A |
| Protective treatment |
TH conforming to IEC 60068-2-30 |
| Pollution degree |
3 |
| Operating altitude |
0...3000 m |
| Fire resistance |
850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness |
- vibrations contactor open: 2 Gn, 5...300 Hz
- vibrations contactor closed: 4 Gn, 5...300 Hz
- shocks contactor open: 10 Gn for 11 ms
- shocks contactor closed: 15 Gn for 11 ms
|
| Unit type of package 1 |
PCE |
| Number of units in package 1 |
1 |
| Package 1 height |
14.000 cm |
| Package 1 width |
16.000 cm |
| Package 1 length |
19.500 cm |
| Package 1 weight |
2.357 kg |
| Unit type of package 2 |
S03 |
| Number of units in package 2 |
4 |
| Package 2 height |
30.000 cm |
| Package 2 width |
30.000 cm |
| Package 2 length |
40.000 cm |
| Package 2 weight |
9.931 kg |
| Green premium status for reporting |
Green Premium product |
| Total lifecycle carbon footprint |
83 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] |
14.787679731830558 |
| Carbon footprint of the manufacturing phase [a1 to a3] |
15 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] |
0.22315092549535964 |
| Carbon footprint of the distribution phase [a4] |
0.2 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] |
0.14475197583712 |
| Carbon footprint of the installation phase [a5] |
0.1 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] |
64.21440873003289 |
| Carbon footprint of the use phase [b2, b3, b4, b6] |
64 kg CO2 eq. |
| Sustainable packaging |
Yes |
| Carbon footprint of the end-of-life phase [c1 to c4] |
3.228596373063081 |
| Carbon footprint of the end-of-life phase [c1 to c4] |
3 kg CO2 eq. |
| Halogen-free status |
Halogen free plastic parts & cables product |
| F-gas free |
N/A |
| Take-back |
No |
| Product contributes to saved and avoided emissions |
No |
| Removable battery |
N/A |
| Total lifecycle carbon footprint |
82.598587736259 |
| Average percentage of recycled metal content |
0 % |
| Packaging made with recycled cardboard |
Yes |
| Packaging without single use plastic |
Yes |
| Scip number |
9bb0b51e-73b5-4128-a86b-723dbbccfe86 |
| Halogen-free status |
Halogen free plastic parts & cables product |
| End of life manual availability |
ENVEOLI1607010 |
| Take-back |
No |
| Weee label |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) |
18 |