Browse all
Browse all

TeSys K Control Relay 3NO+2NC, 0 to 690V, 42VAC 50/60Hz standard coil, screw clamp

TeSys K Control Relay 3NO+2NC, 0 to 690V, 42VAC 50/60Hz standard coil, screw clamp

Item Number: CAD32D7

Datasheet

Product Dimensions

Width icon

Width45 mm

Height icon

Height77 mm

Depth icon

Depth84 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range
  • TeSys
  • TeSys Deca
Range of product TeSys D control relay
Product or component type control relay
Warranty 18 months

Physical

[ue] rated operational voltage <= 690 V AC 25...400 Hz
Mounting support
  • rail
  • plate
Connections - terminals
  • screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
  • screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
  • screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
  • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
  • screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
  • screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
Mechanical durability 30 Mcycles
Insulation resistance > 10 MOhm
Height 77 mm
Width 45 mm
Depth 84 mm
Net weight 0.58 kg
Standards
  • EN/IEC 60947-5-1
  • GB/T 14048.5
  • UL 60947-5-1
  • CSA C22.2 No 60947-5-1
  • JIS C8201-5-1
Product certifications
  • CB
  • CCC
  • UL
  • CSA
  • EAC
  • CE
  • UKCA
Ip degree of protection IP2X front face conforming to VDE 0106
Ambient air temperature for operation
  • -40...60 °C
  • 60...70 °C with derating
Ambient air temperature for storage -60...80 °C
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP1501004EN
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant By Exemption
California proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Others

Life cycle assessment data Yes
Substance regulation data deliverable Yes
Legacy weee scope In
Package 1 bare product quantity 1
Package 2 bare product quantity 20
Average percentage of recycled plastic content 0 %
At least in Europe
Warranty duration(in months) bmecat 18
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Product name TeSys CAD
Device short name CAD
Contactor application control circuit
Utilisation category
  • AC-15
  • AC-14
  • DC-13
Pole contact composition 3 NO + 2 NC
Control circuit type AC at 50/60 Hz
[uc] control circuit voltage 42 V AC 50/60 Hz
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
[ith] conventional free air thermal current 10 A (at 60 °C)
Irms rated making capacity
  • 140 A AC conforming to IEC 60947-5-1
  • 250 A DC conforming to IEC 60947-5-1
[icw] rated short-time withstand current
  • 100 A - 1 s
  • 120 A - 500 ms
  • 140 A - 100 ms
Associated fuse rating 10 A gG conforming to IEC 60947-5-1
[ui] rated insulation voltage
  • 600 V UL certified
  • 600 V CSA certified
  • 690 V conforming to IEC 60947-5-1
Tightening torque
  • 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Control circuit voltage limits
  • 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
  • 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz
  • 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
  • 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Operating time
  • 12...22 ms coil energisation and NO closing
  • 4...12 ms coil de-energisation and NO opening
  • 4...19 ms coil energisation and NC opening
  • 6...17 ms coil de-energisation and NC closing
Maximum operating rate 180 cyc/mn
Inrush power in va 70 VA 50 Hz (at 20 °C)
Hold-in power consumption in va 8 VA 50 Hz (at 20 °C)
Minimum switching voltage 17 V
Minimum switching current 5 mA
Non-overlap time
  • 1.5 ms on energisation between NC and NO contact
  • 1.5 ms on de-energisation between NC and NO contact
Mechanical robustness
  • shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
  • shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
  • vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
  • vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Compatibility code CAD
Protective treatment TH conforming to IEC 60068
Operating altitude 0...3000 m
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 5.000 cm
Package 1 width 9.200 cm
Package 1 length 11.300 cm
Package 1 weight 360.000 g
Unit type of package 2 S02
Number of units in package 2 20
Package 2 height 15.000 cm
Package 2 width 30.000 cm
Package 2 length 40.000 cm
Package 2 weight 7.535 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 18 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 2.4052974453589133
Carbon footprint of the manufacturing phase [a1 to a3] 2 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.2688271654154445
Carbon footprint of the distribution phase [a4] 0.3 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.09473546449819852
Carbon footprint of the installation phase [a5] 0.1 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 15.364183683872902
Carbon footprint of the use phase [b2, b3, b4, b6] 15 kg CO2 eq.
Sustainable packaging Yes
F-gas free N/A
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 18.13304375914546
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
Scip number b67ac941-f42f-4afd-894a-0b6f9cefde62
China rohs label 3
End of life manual availability ENVEOLI1501004
Take-back No
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Environmental Disclosure

  • End of Life Manual

  • Installation Instruction

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.