Browse all
Browse all

TeSys K Control Relay 1 NO + 1 NC, <= 690 V, 220 V AC coil

TeSys K Control Relay 1 NO + 1 NC, <= 690 V, 220 V AC coil

Item Number: CA2SK11M7

Datasheet

Product Dimensions

Width icon

Width27 mm

Height icon

Height56 mm

Depth icon

Depth55.5 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys SK control relay

Range

TeSys

Product or component type

control relay

Warranty

18 months

Physical

[ue] rated operational voltage

<= 690 V <= 400 Hz

Mounting support

  • rail
  • plate

Connections - terminals

  • screw clamp terminals 1 cable(s) 1.5-6 mm²solid
  • screw clamp terminals 2 cable(s) 1.5-4 mm²solid
  • screw clamp terminals 1 cable(s) 0.5-6 mm²flexible without cable end
  • screw clamp terminals 1 cable(s) 0.35-6 mm²flexible with cable end
  • screw clamp terminals 2 cable(s) 0.35-1.5 mm²flexible with cable end
  • screw clamp terminals 2 cable(s) 0.35-2.5 mm²flexible without cable end

Mechanical durability

10 Mcycles

Height

56 mm

Width

27 mm

Depth

55.5 mm

Net weight

0.132 kg

Standards

  • EN/IEC 60947-5-1
  • UL 60947-5-1
  • CSA C22.2 No 60947-5-1

Product certifications

  • CB Scheme
  • cULus
  • EAC
  • CE
  • UKCA

Ip degree of protection

IP2X

Ambient air temperature for operation

-20...50 °C

Ambient air temperature for storage

-50...70 °C

Mercury free

Yes

Rohs exemption information

Yes

Environmental disclosure

ENVPEP1503003EN

Reach regulation

Reference contains Substances of Very High Concern above the threshold

China rohs regulation

Product out of China RoHS scope

Eu rohs directive

Compliant By Exemption

Others

Legacy weee scope

In

Average percentage of recycled plastic content

0 %

Package 1 bare product quantity

1

At least in Europe

Warranty duration(in months) bmecat

18

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Product name

TeSys CASK

Device short name

CA2SK

Contactor application

control circuit

Utilisation category

  • DC-13
  • AC-15

Pole contact composition

1 NO + 1 NC

Control circuit type

AC at 50/60 Hz

[uc] control circuit voltage

220 V AC 50/60 Hz

[ith] conventional free air thermal current

10 A (at 55 °C)

Associated fuse rating

  • 10 A gL conforming to VDE 0660
  • 10 A gL conforming to IEC 60947

[ui] rated insulation voltage

  • 690 V conforming to IEC 60947
  • 690 V conforming to VDE 0110 group C
  • 690 V conforming to BS 5424
  • 690 V conforming to UL 508
  • 690 V conforming to CSA C22.2 No 14

Tightening torque

0.8 N.m - on screw clamp terminals pozidriv No 1 screw head

Control circuit voltage limits

  • drop-out: 0.2...0.75 Uc (at <50 °C)
  • operational: 0.85...1.1 Uc (at <50 °C)

Operating time

  • 6...8 ms coil de-energisation and NO opening
  • 7...14 ms coil energisation and NO closing
  • 8...10 ms coil de-energisation and NC closing
  • 8...16 ms coil energisation and NC opening

Maximum operating rate

1200 cyc/h

Inrush power in va

16 VA (at 20 °C)

Hold-in power consumption in va

4.2...4.2 VA (at 20 °C)

Heat dissipation

1.4...1.4 W

Compatibility code

CA2SK

Protective treatment

TC conforming to IEC 60068

Operating altitude

2000 m without derating

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

3.500 cm

Package 1 width

6.000 cm

Package 1 length

6.500 cm

Package 1 weight

121.400 g

Unit type of package 2

S01

Number of units in package 2

40

Package 2 height

15.000 cm

Package 2 width

15.000 cm

Package 2 length

40.000 cm

Package 2 weight

5.000 kg

Unit type of package 3

P06

Number of units in package 3

1280

Package 3 height

75.000 cm

Package 3 width

80.000 cm

Package 3 length

60.000 cm

Package 3 weight

168.013 kg

Total lifecycle carbon footprint

58 kg CO2 eq.

Carbon footprint of the manufacturing phase [a1 to a3]

0.6213248859540139

Carbon footprint of the manufacturing phase [a1 to a3]

0.6 kg CO2 eq.

Carbon footprint of the distribution phase [a4]

0.23979943744781793

Carbon footprint of the distribution phase [a4]

0.2 kg CO2 eq.

Carbon footprint of the installation phase [a5]

0.016485215458911535

Carbon footprint of the installation phase [a5]

0 kg CO2 eq.

Carbon footprint of the use phase [b2, b3, b4, b6]

56.65241524409139

Carbon footprint of the use phase [b2, b3, b4, b6]

57 kg CO2 eq.

Sustainable packaging

Yes

Carbon footprint of the end-of-life phase [c1 to c4]

0.1741398844597613

Carbon footprint of the end-of-life phase [c1 to c4]

0.2 kg CO2 eq.

F-gas free

N/A

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Total lifecycle carbon footprint

57.704164667411895

Average percentage of recycled metal content

0 %

Packaging made with recycled cardboard

Yes

Packaging without single use plastic

Yes

Scip number

bf876e8d-5be9-45ba-9d97-ac1c3aec5384

China rohs label

3

End of life manual availability

ENVEOLI1503003

Take-back

No

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Warranty (in months)

18
Show all specifications

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.