TeSys D Contactor TeSys Deca, 4P(4NO), AC-1 <=440V 200A, 110V AC 50/60Hz coil, lugs/bars terminals

TeSys D Contactor TeSys Deca, 4P(4NO), AC-1 <=440V 200A, 110V AC 50/60Hz coil, lugs/bars terminals

Item Number: LC1D1150046F7

Datasheet

Product Dimensions

Width icon

Width155 mm

Height icon

Height158 mm

Depth icon

Depth115 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range TeSys
Range of product TeSys Deca
Product or component type contactor
Warranty 18 months

Physical

[ue] rated operational voltage
  • power circuit: <= 1000 V AC 25...400 Hz
  • power circuit: <= 460 V DC
[ie] rated operational current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Mechanical durability 8 Mcycles
Electrical durability 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
Connections - terminals
  • control circuit: lugs-ring terminals - external diameter: 8 mm
  • power circuit: lugs-ring terminals - external diameter: 25 mm
  • power circuit: bars 1 - busbar cross section: 5 x 25 mm
Mounting support
  • rail
  • plate
Standards
  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 508
Product certifications
  • LROS (Lloyds register of shipping)
  • DNV
  • BV
  • RINA
  • CSA
  • UL
  • CCC
  • GOST
  • GL
  • UKCA
Ip degree of protection IP20 front face conforming to IEC 60529
Climatic withstand
  • conforming to IACS E10 exposure to damp heat
  • conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Height 158 mm
Width 155 mm
Depth 115 mm
Net weight 2.86 kg
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP0603001EN
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant By Exemption

Others

Life cycle assessment data Yes
Substance regulation data deliverable Yes
Package 1 bare product quantity 1
Average percentage of recycled plastic content 0 %
Legacy weee scope In
At least in Europe
Warranty duration(in months) bmecat 18
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Device short name LC1D
Contactor application resistive load
Utilisation category
  • AC-1
  • AC-3
  • AC-3e
  • AC-4
Poles description 4P
[uc] control circuit voltage 110 V AC 50/60 Hz
Compatibility code LC1D
Pole contact composition 4 NO
Contact compatibility M14
Protective cover with
[ith] conventional free air thermal current 200 A (at 60 °C) for power circuit
Irms rated making capacity 1260 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current
  • 250 A 40 °C - 10 min for power circuit
  • 550 A 40 °C - 1 min for power circuit
  • 950 A 40 °C - 10 s for power circuit
  • 1100 A 40 °C - 1 s for power circuit
Associated fuse rating
  • 250 A gG at <= 690 V coordination type 1 for power circuit
  • 200 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
Power dissipation per pole 24 W AC-1
[ui] rated insulation voltage
  • power circuit: 600 V CSA certified
  • power circuit: 600 V UL certified
  • power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level
  • B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Control circuit type AC at 50/60 Hz
Coil technology built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
  • 0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz
  • 0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz
  • 1...1.15 Uc (55-70 °C):operational AC 50/60 Hz
Inrush power in va
  • 280...350 VA 60 Hz cos phi 0.8 (at 20 °C)
  • 280...350 VA 50 Hz cos phi 0.8 (at 20 °C)
Hold-in power consumption in va
  • 2...18 VA 60 Hz cos phi 0.3 (at 20 °C)
  • 2...18 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 3...8 W at 50/60 Hz
Operating time
  • 6...20 ms opening
  • 20...50 ms closing
Maximum operating rate 2400 cyc/h at 60 °C
Tightening torque
  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
  • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
  • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5
Protective treatment TH conforming to IEC 60068-2-30
Permissible ambient air temperature around the device
  • -40...60 °C
  • 60...70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness
  • vibrations contactor open (2 Gn, 5...300 Hz)
  • vibrations contactor closed (4 Gn, 5...300 Hz)
  • shocks contactor closed (15 Gn for 11 ms)
  • shocks contactor open (6 Gn for 11 ms)
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 16.8 cm
Package 1 width 21.2 cm
Package 1 length 18.5 cm
Package 1 weight 2.37 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 219 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 25.42976168377488
Carbon footprint of the manufacturing phase [a1 to a3] 25 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.859021505025635
Carbon footprint of the distribution phase [a4] 0.9 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.3036665300058981
Carbon footprint of the installation phase [a5] 0.3 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 187.29208633093518
Carbon footprint of the use phase [b2, b3, b4, b6] 187 kg CO2 eq.
Sustainable packaging No
Carbon footprint of the end-of-life phase [c1 to c4] 5.063122083295763
Carbon footprint of the end-of-life phase [c1 to c4] 5 kg CO2 eq.
Pvc free Yes
F-gas free N/A
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 218.94765813303735
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic No
Scip number a530c666-91dd-4119-8d61-f1c22a361ecb
Pvc free Yes
End of life manual availability ENVEOLI100405EN
Take-back No
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

  • Product Change Notification

Important: Some software files may need a mySchneider or Club login to download.