TeSys D Contactor TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24 to 60VAC/DC coil, EverLink
Item Number: LC1D40ABNE
Datasheet
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| - | |||
| - | |||
| - |
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| 1 | PCE | 3606480988202 | - |
Specifications
Design
| Range of product | TeSys Deca Advanced |
|---|---|
| Product or component type | contactor |
| Warranty | 18 months |
Physical
| [ue] rated operational voltage | power circuit: <= 690 V AC 25...400 Hz |
|---|---|
| [ie] rated operational current |
|
| Mechanical durability | 10 Mcycles |
| Electrical durability |
|
| Connections - terminals |
|
| Insulation resistance | > 10 MOhm for signalling circuit |
| Mounting support |
|
| Connections - terminals | EverLink BTR screw connectors |
| Standards |
|
| Product certifications |
|
| Ip degree of protection | IP20 front face conforming to IEC 60529 |
| Climatic withstand |
|
| Height | 122 mm |
| Width | 55 mm |
| Depth | 120 mm |
| Net weight | 0.992 kg |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP1607010EN |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | Product out of China RoHS scope |
| Eu rohs directive | Compliant By Exemption |
Others
| Life cycle assessment data | Yes |
|---|---|
| Substance regulation data deliverable | Yes |
| Legacy weee scope | In |
| At least in Europe | |
| Warranty duration(in months) bmecat | 18 |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Package 1 bare product quantity | 1 |
| Package 2 bare product quantity | 10 |
| Average percentage of recycled plastic content | 0 % |
| Device short name | LC1D |
| Contactor application |
|
| Utilisation category |
|
| Poles description | 3P |
| [uc] control circuit voltage |
|
| Motor power kw |
|
| Motor power hp |
|
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | with |
| [ith] conventional free air thermal current |
|
| Irms rated making capacity |
|
| Rated breaking capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
| [icw] rated short-time withstand current |
|
| Associated fuse rating |
|
| Average impedance | 1.5 mOhm - Ith 60 A 50 Hz for power circuit |
| Power dissipation per pole |
|
| [ui] rated insulation voltage |
|
| Overvoltage category | III |
| Pollution degree | 3 |
| [uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level |
|
| Control circuit type | AC/DC at 50/60 Hz AC/DC electronic |
| Coil technology | built-in bidirectional peak limiting |
| Control circuit voltage limits |
|
| Inrush power in va | 18 VA 50/60 Hz (at 20 °C) |
| Inrush power in w | 18 W (at 20 °C) |
| Hold-in power consumption in va | 1.2...1.2 VA 50/60 Hz (at 20 °C) |
| Hold-in power consumption in w | 0.7...0.7 W at 20 °C |
| Heat dissipation | 0.7...0.7 W at 50/60 Hz |
| Operating time |
|
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Tightening torque |
|
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type |
|
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Non-overlap time |
|
| [uc] control circuit voltage | 24...60 V |
| Maximum motor phase current | 40 A |
| Permissible ambient air temperature around the device |
|
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness |
|
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 6.200 cm |
| Package 1 width | 13.700 cm |
| Package 1 length | 15.200 cm |
| Package 1 weight | 884.000 g |
| Unit type of package 2 | S02 |
| Number of units in package 2 | 10 |
| Package 2 height | 15.000 cm |
| Package 2 width | 30.000 cm |
| Package 2 length | 40.000 cm |
| Package 2 weight | 9.116 kg |
| Green premium status for reporting | Green Premium product |
| Total lifecycle carbon footprint | 29 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] | 6.673660658196258 |
| Carbon footprint of the manufacturing phase [a1 to a3] | 7 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] | 0.10070772286965905 |
| Carbon footprint of the distribution phase [a4] | 0.1 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] | 0.06532637870571324 |
| Carbon footprint of the installation phase [a5] | 0.1 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 20.485578245163865 |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 20 kg CO2 eq. |
| Sustainable packaging | Yes |
| Carbon footprint of the end-of-life phase [c1 to c4] | 1.4570613501810656 |
| Carbon footprint of the end-of-life phase [c1 to c4] | 1 kg CO2 eq. |
| Halogen-free status | Halogen free plastic parts & cables product |
| F-gas free | N/A |
| Take-back | No |
| Product contributes to saved and avoided emissions | No |
| Removable battery | N/A |
| Total lifecycle carbon footprint | 28.78233435511656 |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | Yes |
| Scip number | 9bb0b51e-73b5-4128-a86b-723dbbccfe86 |
| Halogen-free status | Halogen free plastic parts & cables product |
| End of life manual availability | ENVEOLI1607010 |
| Take-back | No |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) | 18 |
Documents & downloads
-
All
-
Product Brochures
-
CAD Files and Packs
-
Technical Data Catalogues
-
Environmental Disclosure
-
End of Life Manual
-
Data Bulletin
-
Installation Instruction
-
Technical illustration
-
Technical Drawing
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)
TeSys - Catalog 2026 - Innovative and connected solutions for motor starters
VERSION
17.0
DATE
11 May 2026
REVISION
17.0
Discover catalog for Altivar Soft Starter ATS490
VERSION
1.0
DATE
23 May 2025
REVISION
1.0
Discover catalog for Altivar Soft Starter ATS430
VERSION
1.0
DATE
18 Apr 2025
REVISION
1.0
Catalog Safety chain solutions & Safety functions English 07/2020
VERSION
2.1
DATE
08 May 2024
REVISION
2.1
CCC_TeSys Deca_LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A_Le Vaudreuil
VERSION
1.0
DATE
08 Apr 2026
REVISION
1.0
UL Certificate_TeSys D_ LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A&DPE40-65
VERSION
1.0
DATE
17 Dec 2025
REVISION
1.0
CB_ TeSys_LC1D40A-65A&LC2D40A-65A_SSIC
VERSION
1.0
DATE
11 Dec 2025
REVISION
1.0
DNV Type Approval Certificate_TeSys D_LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A
VERSION
1.0
DATE
04 Sep 2025
REVISION
1.0
EU RO MR Type Approval Certificate_TeSys D_LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A
VERSION
1.0
DATE
04 Sep 2025
REVISION
1.0
CCC_TeSys Deca_LC1D40A-65A&LC2D40A-65A_SSIC
VERSION
1.0
DATE
24 Mar 2025
REVISION
1.0
CB Certificate_TeSys Deca_LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80_Le Vaudreuil
VERSION
1.0
DATE
24 Mar 2025
REVISION
1.0
CSA Certificate_ TeSys D_LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A
VERSION
1.0
DATE
13 Dec 2023
REVISION
1.0
LC1D40ABNE EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D40ABNE EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D40ABNE EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D40ABNE EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D40ABNE EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D40ABNE EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D40ABNE EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D40ABNE EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D40ABNE REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D40ABNE REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D40ABNE REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D40ABNE REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
Recently viewed
DISCONTINUED
LC1D40ABNE
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24 to 60VAC/DC coil, EverLink
DISCONTINUED
1235NPT4
Clipsal - Cable Management Brass Adaptor
1 Inch NPT Male to 20mm Female
DISCONTINUED
GV4PEM07S
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic multifunction, Everlink terminals
DISCONTINUED
LC1DT60AX7
TeSys D Contactor
4P(4 NO) - AC-1 - <= 440 V 60 A - 600 V AC 50/60 Hz coil
DISCONTINUED
LC1D50AT7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 50A, 480VAC 60Hz coil
DISCONTINUED
56L1/30
Clipsal - 56 Series Lid
1 Gang with 1 X 30mm Diameter Aperture. Lid Made of Plastic & Includes Gasket
DISCONTINUED
LC1D40ABNE
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24 to 60VAC/DC coil, EverLink
DISCONTINUED
1235NPT4
Clipsal - Cable Management Brass Adaptor
1 Inch NPT Male to 20mm Female
DISCONTINUED
GV4PEM07S
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic multifunction, Everlink terminals
DISCONTINUED
LC1DT60AX7
TeSys D Contactor
4P(4 NO) - AC-1 - <= 440 V 60 A - 600 V AC 50/60 Hz coil
DISCONTINUED
LC1D50AT7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 50A, 480VAC 60Hz coil
DISCONTINUED
56L1/30
Clipsal - 56 Series Lid
1 Gang with 1 X 30mm Diameter Aperture. Lid Made of Plastic & Includes Gasket