Browse all
Browse all

TeSys D Contactor TeSys Deca, 3P(3 NO) , AC-3 , <= 440V, 80 A , 48V DC wide range coil

TeSys D Contactor TeSys Deca, 3P(3 NO) , AC-3 , <= 440V, 80 A , 48V DC wide range coil

Item Number: LC1D80EW

Datasheet

Product Dimensions

Width icon

Width85 mm

Height icon

Height127 mm

Depth icon

Depth186 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range TeSys
Range of product TeSys Deca
Product or component type contactor
Warranty 18 months

Physical

[ue] rated operational voltage
  • power circuit: <= 300 V DC 25...400 Hz
  • power circuit: <= 690 V AC
[ie] rated operational current
  • 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
  • 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
  • 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Mechanical durability 10 Mcycles
Electrical durability
  • 0.8 Mcycles 125 A AC-1 at Ue <= 440 V
  • 1.5 Mcycles 80 A AC-3 at Ue <= 440 V
Connections - terminals
  • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
  • control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
  • power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end
  • power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end
  • power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end
  • power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end
  • power circuit: connector 1 4-50 mm² - cable stiffness: solid without cable end
  • power circuit: connector 2 4-25 mm² - cable stiffness: solid without cable end
Insulation resistance > 10 MOhm for signalling circuit
Mounting support
  • rail
  • plate
Standards
  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 508
Product certifications
  • CSA
  • GOST
  • CCC
  • DNV
  • BV
  • UL
  • GL
  • LROS (Lloyds register of shipping)
  • RINA
Ip degree of protection IP20 front face conforming to IEC 60529
Climatic withstand conforming to IACS E10 exposure to damp heat
Height 127 mm
Width 85 mm
Depth 186 mm
Net weight 2.59 kg
Reach free of svhc Yes
Toxic heavy metal free Yes
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP110205EN
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant

Others

At least in Europe
Warranty duration(in months) bmecat 18
Legacy weee scope In
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Device short name LC1D
Contactor application
  • motor control
  • resistive load
Utilisation category
  • AC-3
  • AC-3e
  • AC-4
  • AC-1
Poles description 3P
[uc] control circuit voltage 48 V DC
Motor power kw
  • 22 kW at 220...230 V AC 50/60 Hz (AC-3)
  • 37 kW at 380...400 V AC 50/60 Hz (AC-3)
  • 45 kW at 415...440 V AC 50/60 Hz (AC-3)
  • 55 kW at 500 V AC 50/60 Hz (AC-3)
  • 45 kW at 660...690 V AC 50/60 Hz (AC-3)
  • 15 kW at 400 V AC 50/60 Hz (AC-4)
  • 22 kW at 220...230 V AC 50/60 Hz (AC-3e)
  • 37 kW at 380...400 V AC 50/60 Hz (AC-3e)
  • 45 kW at 415...440 V AC 50/60 Hz (AC-3e)
  • 55 kW at 500 V AC 50/60 Hz (AC-3e)
  • 45 kW at 660...690 V AC 50/60 Hz (AC-3e)
Motor power hp
  • 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors
  • 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
  • 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
  • 30 hp at 230/240 V AC 50/60 Hz for 3 phases motors
  • 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors
  • 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Contact compatibility M9
Protective cover with
[ith] conventional free air thermal current
  • 10 A (at 60 °C) for signalling circuit
  • 125 A (at 60 °C) for power circuit
Irms rated making capacity
  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
  • 250 A DC for signalling circuit conforming to IEC 60947-5-1
  • 1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current
  • 640 A 40 °C - 10 s for power circuit
  • 990 A 40 °C - 1 s for power circuit
  • 135 A 40 °C - 10 min for power circuit
  • 320 A 40 °C - 1 min for power circuit
  • 100 A - 1 s for signalling circuit
  • 120 A - 500 ms for signalling circuit
  • 140 A - 100 ms for signalling circuit
Associated fuse rating
  • 10 A gG for signalling circuit conforming to IEC 60947-5-1
  • 200 A gG at <= 690 V coordination type 1 for power circuit
  • 160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole
  • 5.1 W AC-3
  • 12.5 W AC-1
[ui] rated insulation voltage
  • power circuit: 600 V CSA certified
  • power circuit: 600 V UL certified
  • power circuit: 1000 V conforming to IEC 60947-4-1
  • signalling circuit: 690 V conforming to IEC 60947-1
  • signalling circuit: 600 V CSA certified
  • signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level
  • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Control circuit type DC wide range
Coil technology without built-in suppressor module
Control circuit voltage limits
  • 0.75...1.2 Uc (-40-55 °C):operational DC
  • 0.1...0.3 Uc (-40-70 °C):drop-out DC
  • 1...1.2 Uc (55-70 °C):operational DC
Inrush power in w 22 W (at 20 °C)
Hold-in power consumption in w 22 W at 20 °C
Operating time
  • 95...130 ms closing
  • 20...35 ms opening
Time constant 75 ms
Tightening torque
  • control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
  • power circuit: 12 N.m - on connector hexagonal screw head 4 mm
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type
  • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
  • type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Non-overlap time
  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact
Protective treatment TH conforming to IEC 60068-2-30
Permissible ambient air temperature around the device
  • -40...60 °C
  • 60...70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness
  • vibrations contactor open (2 Gn, 5...300 Hz)
  • shocks contactor open (8 Gn for 11 ms)
  • vibrations contactor closed (3 Gn, 5...300 Hz)
  • shocks contactor closed (10 Gn for 11 ms)
Unit type of package 1 PCE
Number of units in package 1 1
Sustainable packaging No
Pvc free Yes
China rohs label 1
Pvc free Yes
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18