| Life cycle assessment data |
Yes |
| Substance regulation data deliverable |
Yes |
| Legacy weee scope |
In |
| |
At least in Europe |
| Average percentage of recycled plastic content |
0 % |
| Package 1 bare product quantity |
1 |
| Warranty duration(in months) bmecat |
18 |
| Weee label |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Device short name |
LC1D |
| Contactor application |
- motor control
- resistive load
|
| Utilisation category |
|
| Poles description |
3P |
| [uc] control circuit voltage |
110 V DC |
| Motor power kw |
- 11 kW at 220/230 V AC 50/60 Hz (AC-3)
- 18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
- 22 kW at 415/440 V AC 50/60 Hz (AC-3)
- 22 kW at 500 V AC 50/60 Hz (AC-3)
- 30 kW at 660/690 V AC 50/60 Hz (AC-3)
- 9 kW at 400 V AC 50/60 Hz (AC-4)
|
| Motor power hp |
- 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
- 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
- 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
- 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
- 3 hp at 115 V AC 50/60 Hz for 1 phase motors
- 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors
|
| Compatibility code |
LC1D |
| Pole contact composition |
3 NO |
| Protective cover |
with |
| [ith] conventional free air thermal current |
- 10 A (at 60 °C) for signalling circuit
- 60 A (at 60 °C) for power circuit
|
| Irms rated making capacity |
- 140 A AC for signalling circuit conforming to IEC 60947-5-1
- 250 A DC for signalling circuit conforming to IEC 60947-5-1
- 800 A at 440 V for power circuit conforming to IEC 60947
|
| Rated breaking capacity |
800 A at 440 V for power circuit conforming to IEC 60947 |
| [icw] rated short-time withstand current |
- 320 A 40 °C - 10 s for power circuit
- 720 A 40 °C - 1 s for power circuit
- 72 A 40 °C - 10 min for power circuit
- 165 A 40 °C - 1 min for power circuit
- 100 A - 1 s for signalling circuit
- 120 A - 500 ms for signalling circuit
- 140 A - 100 ms for signalling circuit
|
| Associated fuse rating |
- 10 A gG for signalling circuit conforming to IEC 60947-5-1
- 80 A gG at <= 690 V coordination type 1 for power circuit
- 80 A gG at <= 690 V coordination type 2 for power circuit
|
| Average impedance |
1.5 mOhm - Ith 60 A 50 Hz for power circuit |
| Power dissipation per pole |
|
| [ui] rated insulation voltage |
- power circuit: 600 V CSA certified
- power circuit: 600 V UL certified
- signalling circuit: 690 V conforming to IEC 60947-1
- signalling circuit: 600 V CSA certified
- signalling circuit: 600 V UL certified
- power circuit: 690 V conforming to IEC 60947-4-1
|
| Overvoltage category |
III |
| Pollution degree |
3 |
| [uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947 |
| Safety reliability level |
- B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
- B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
|
| Control circuit type |
DC standard |
| Coil technology |
built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits |
- 0.1...0.3 Uc (-40-70 °C):drop-out DC
- 0.75...1.25 Uc (-40-60 °C):operational DC
- 1...1.25 Uc (60-70 °C):operational DC
|
| Inrush power in w |
19 W (at 20 °C) |
| Hold-in power consumption in w |
7.4...7.4 W at 20 °C |
| Operating time |
- 50 ±15 % ms closing
- 20 ±20 % ms opening
|
| Time constant |
34 ms |
| Maximum operating rate |
3600 cyc/h at 60 °C |
| Tightening torque |
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
- power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm
- power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
- power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
|
| Auxiliary contact composition |
1 NO + 1 NC |
| Auxiliary contacts type |
- type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
- type mirror contact 1 NC conforming to IEC 60947-4-1
|
| Signalling circuit frequency |
25...400 Hz |
| Minimum switching voltage |
17 V for signalling circuit |
| Minimum switching current |
5 mA for signalling circuit |
| Non-overlap time |
- 1.5 ms on de-energisation between NC and NO contact
- 1.5 ms on energisation between NC and NO contact
|
| Contact compatibility |
M4 |
| Maximum motor phase current |
40 A |
| [uc] control circuit voltage |
110 V |
| Protective treatment |
TH conforming to IEC 60068-2-30 |
| Permissible ambient air temperature around the device |
- -40...60 °C
- 60...70 °C with derating
|
| Operating altitude |
0...3000 m |
| Fire resistance |
850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness |
- vibrations contactor open (2 Gn, 5...300 Hz)
- vibrations contactor closed (4 Gn, 5...300 Hz)
- shocks contactor closed (15 Gn for 11 ms)
- shocks contactor open (10 Gn for 11 ms)
|
| Unit type of package 1 |
PCE |
| Number of units in package 1 |
1 |
| Package 1 height |
6.2 cm |
| Package 1 width |
13.7 cm |
| Package 1 length |
15.2 cm |
| Package 1 weight |
994.0 g |
| Unit type of package 2 |
S02 |
| Number of units in package 2 |
10 |
| Package 2 height |
15 cm |
| Package 2 width |
30 cm |
| Package 2 length |
40 cm |
| Package 2 weight |
10.281 kg |
| Green premium status for reporting |
Green Premium product |
| Total lifecycle carbon footprint |
79 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] |
4.573365611546233 |
| Carbon footprint of the manufacturing phase [a1 to a3] |
5 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] |
0.42873297932635546 |
| Carbon footprint of the distribution phase [a4] |
0.4 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] |
0.05584611554662137 |
| Carbon footprint of the installation phase [a5] |
0.1 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] |
72.48743071365675 |
| Carbon footprint of the use phase [b2, b3, b4, b6] |
72 kg CO2 eq. |
| Sustainable packaging |
Yes |
| Carbon footprint of the end-of-life phase [c1 to c4] |
1.2994321372133595 |
| Carbon footprint of the end-of-life phase [c1 to c4] |
1 kg CO2 eq. |
| Pvc free |
Yes |
| F-gas free |
N/A |
| Take-back |
No |
| Product contributes to saved and avoided emissions |
No |
| Removable battery |
N/A |
| Total lifecycle carbon footprint |
78.84480755728931 |
| Average percentage of recycled metal content |
0 % |
| Packaging made with recycled cardboard |
Yes |
| Packaging without single use plastic |
Yes |
| China rohs label |
1 |
| Pvc free |
Yes |
| End of life manual availability |
ENVEOLI1503009EN |
| Take-back |
No |
| Weee label |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) |
18 |