Specifications

Design

Range Square D
Range of product Square D
Product or component type residual current breaker with overcurrent protection (RCBO)

Physical

[in] rated current 16 A at 40 °C
[ue] rated operational voltage 230/240 V AC 50/60 Hz
Electrical insulation class class II
Control type toggle
Local signalling ON/OFF indication
Mounting mode plug-on
Mounting support socket
Height 110 mm
Width 19 mm
Depth 85 mm
Net weight 186 g
Mechanical durability 20000 cycles
Electrical durability 5000 cycles
Connections - terminals
  • plug-in connector (top)
  • tunnel type terminal (bottom) 1-16 mm² rigid without cable end
  • tunnel type terminal (bottom) 1-10 mm² with cable end
  • tunnel type terminal (bottom) 1-10 mm² flexible without cable end
Wire stripping length power circuit: 15 mm for bottom connection
Standards
  • BS EN 61009-1
  • IEC 61009-2-2
  • IEC 61009-1
  • AS/NZS 61009.1
Ip degree of protection IP20
Relative humidity 95 % at 55 °C
Ambient air temperature for operation -15...60 °C
Ambient air temperature for storage -40...85 °C
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP1306051EN
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant By Exemption

Others

Legacy weee scope In
Package 1 bare product quantity 1
Package 2 bare product quantity 34
Package 3 bare product quantity 544
Average percentage of recycled plastic content 0 %
At least in Europe
Warranty duration(in months) bmecat 18
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Circuit breaker application distribution
Product name QOvs RCBO
Poles description 1P + Ns
Earthing system TN
Curve code B
Earth-leakage sensitivity 30 mA
Breaking capacity 10000 A Icn at 230/240 V AC 50/60 Hz
Number of protected poles 1
Device location in system outgoer
Network frequency 50/60 Hz
Network type AC
Trip unit technology thermal-magnetic
Residual current tripping technology voltage dependent functional earth
Earth-leakage protection time delay instantaneous
Earth-leakage protection class type AC
[icw] rated short-time withstand current Icw: 250 A during 8/20 µs impulse withstand
[ics] rated service breaking capacity 7500 A at 230/240 V AC 50/60 Hz
Limitation class 3
[ui] rated insulation voltage 400 V AC 50/60 Hz
[uimp] rated impulse withstand voltage 4 kV
Surge current 250 A
Suitability for isolation yes
Contact position indicator yes
Comb busbar and distribution block compatibility NO
Provision for padlocking non padlockable
Tightening torque power circuit: 2 N.m bottom
Earth-leakage protection integrated
Tropicalisation 2
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 2.800 cm
Package 1 width 11.100 cm
Package 1 length 14.000 cm
Package 1 weight 220.500 g
Unit type of package 2 S02
Number of units in package 2 34
Package 2 height 15.000 cm
Package 2 width 30.000 cm
Package 2 length 40.000 cm
Package 2 weight 8.084 kg
Unit type of package 3 P06
Number of units in package 3 544
Package 3 height 75.000 cm
Package 3 width 80.000 cm
Package 3 length 60.000 cm
Package 3 weight 137.600 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 43 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 3.0178174057423393
Carbon footprint of the manufacturing phase [a1 to a3] 3 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.060360271179397636
Carbon footprint of the distribution phase [a4] 0.1 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.04914128733010071
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 39.25704545454545
Carbon footprint of the use phase [b2, b3, b4, b6] 39 kg CO2 eq.
Sustainable packaging Yes
Carbon footprint of the end-of-life phase [c1 to c4] 0.42200405373507105
Carbon footprint of the end-of-life phase [c1 to c4] 0.4 kg CO2 eq.
Halogen-free status Halogen free plastic parts product
Silicone-free  No
F-gas free N/A
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 42.806368472532355
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
Scip number 9a51c76a-1b6a-4c6b-be51-2aebaefb053b
Halogen-free status Halogen free plastic parts product
Silicone-free No
End of life manual availability N/A
Take-back No
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18