| Legacy weee scope |
Out |
| Important message |
We have updated the process to order Telemecanique Sensors productsFor more information, please contact your Telemecanique Sensors representative (https://tesensors.com/global/en/distributors)You can find all product information on the Telemecanique Sensors website: https://tesensors.com |
| Package 1 bare product quantity |
1 |
| Package 2 bare product quantity |
20 |
| Package 3 bare product quantity |
160 |
| Average percentage of recycled plastic content |
0 % |
| |
At least in Europe |
| Warranty duration(in months) bmecat |
18 |
| Weee label |
No |
| Pressure sensor type |
electromechanical pressure sensor |
| Pressure sensor name |
XMP |
| Pressure sensor size |
12 bar |
| Fluid connection type |
G 1/4 (female) conforming to ISO 228 |
| Controlled fluid |
- air (0-70 °C)
- fresh water (0-70 °C)
- sea water (0-70 °C)
|
| Contacts type and composition |
3 NC snap action |
| Product specific application |
- |
| Pressure switch type of operation |
regulation between 2 thresholds |
| Electrical connection |
screw-clamp terminals, clamping capacity: minimum : 2 x 4 mm² |
| Electrical circuit type |
power circuit |
| Scale type |
adjustable differential |
| Local display |
without |
| Adjustable range of switching point on falling pressure |
0.3...10.3 bar |
| Adjustment range high setting |
1.3...12 bar |
| Possible differential minimum at low setting |
1 bar |
| Possible differential minimum at high setting |
1.7 bar |
| Possible differential maximum at high setting |
8.4 bar |
| Destruction pressure |
30 bar |
| Type of decompression valve |
without |
| Terminal block type |
6 terminals |
| Pressure actuator |
diaphragm |
| Materials in contact with fluid |
- canvas covered nitrile
- chromated zinc alloy
|
| Enclosure material |
PA impregnated with fibreglass |
| Operating position |
any position |
| Maximum operating rate |
10 cyc/mn |
| Repeat accuracy |
3.5 % |
| [ui] rated insulation voltage |
500 V conforming to IEC 60947-1 |
| [uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947-1 |
| Maximum resistance across terminals |
- 25 MOhm conforming to IEC 60255-7 category 3
- 25 MOhm conforming to NF C 93-050 method A
|
| Setting |
knurled knob and nut |
| Terminals description iso n°1 |
|
| Vibration resistance |
3 gn conforming to IEC 60068-2-6 (f = 10-500 Hz) |
| Shock resistance |
50 gn conforming to IEC 60068-2-27 |
| Electrical shock protection class |
class I conforming to IEC 60536 |
| Unit type of package 1 |
PCE |
| Number of units in package 1 |
1 |
| Package 1 height |
6.200 cm |
| Package 1 width |
17.000 cm |
| Package 1 length |
11.500 cm |
| Package 1 weight |
530.000 g |
| Unit type of package 2 |
S03 |
| Number of units in package 2 |
20 |
| Package 2 height |
30.000 cm |
| Package 2 width |
30.000 cm |
| Package 2 length |
40.000 cm |
| Package 2 weight |
11.002 kg |
| Unit type of package 3 |
P06 |
| Number of units in package 3 |
160 |
| Package 3 height |
75.000 cm |
| Package 3 width |
60.000 cm |
| Package 3 length |
80.000 cm |
| Package 3 weight |
99.004 kg |
| Sustainable packaging |
No |
| Take-back |
No |
| Product contributes to saved and avoided emissions |
No |
| Removable battery |
N/A |
| Average percentage of recycled metal content |
0 % |
| Packaging made with recycled cardboard |
No |
| Packaging without single use plastic |
No |
| End of life manual availability |
N/A |
| Take-back |
No |
| Warranty (in months) |
18 |