Browse all
Browse all

OsiSense XC Standard Limit Switch XCKP Steel End Plunger 1 Nc

OsiSense XC Standard Limit Switch XCKP Steel End Plunger 1 Nc

Item Number: XCKP2110P16

Datasheet

Product Dimensions

Width icon

Width31 mm

Height icon

Height65 mm

Depth icon

Depth30 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product Telemecanique Limit switches XC Standard
Product or component type limit switch
Warranty 18 months

Physical

Fixing mode by the body
Number of poles 2
Cable entry 1 entry tapped for M16 x 1.5 cable gland, cable outer diameter: 4-8 mm
Electrical durability
  • 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
  • 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
  • 5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability 15000000 cycles
Width 31 mm
Height 65 mm
Depth 30 mm
Net weight 0.09 kg
Device presentation complete product
Ip degree of protection
  • IP66 conforming to IEC 60529
  • IP67 conforming to IEC 60529
Ik degree of protection IK04 conforming to IEC 62262
Ambient air temperature for operation -25...70 °C
Ambient air temperature for storage -40...70 °C
Product certifications
  • CCC
  • CSA
  • UL
Standards
  • IEC 60947-5-1
  • IEC 60204-1
  • CSA C22.2 No 14
  • UL 508
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP110606EN
Eu rohs directive Compliant By Exemption
California proposition 65 WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Material

Material plastic

Others

Important message We have updated the process to order Telemecanique Sensors productsFor more information, please contact your Telemecanique Sensors representative (https://tesensors.com/global/en/distributors)You can find all product information on the Telemecanique Sensors website: https://tesensors.com
Legacy weee scope Out
At least in Europe
Average percentage of recycled plastic content 0 %
Package 2 bare product quantity 81
Package 1 bare product quantity 1
Warranty duration(in months) bmecat 18
Weee label No
Series name standard format
Device short name XCKP
Sensor design compact form B conforming to CENELEC EN 50047
Body type fixed
Head type plunger head
Body material plastic
Head material zamak
Movement of operating head linear
Type of operator spring return plunger metal
Type of approach vertical approach, 1 direction
Contacts type and composition 1 NC + 1 NO
Contact operation snap action
Switch actuation on end
Electrical connection screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Contacts insulation form Zb
Positive opening with
Positive opening minimum force 45 N
Minimum force for tripping 15 N
Minimum actuation speed 0.01 m/min
Maximum actuation speed 0.5 m/s
Repeat accuracy 0.1 mm on the tripping points with 1 million operating cycles
Contact code designation
  • A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to IEC 60947-5-1 appendix A
  • Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
[ui] rated insulation voltage
  • 300 V conforming to UL 508
  • 500 V (pollution degree 3) conforming to IEC 60947-1
  • 300 V conforming to CSA C22.2 No 14
Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3
[uimp] rated impulse withstand voltage
  • 6 kV conforming to IEC 60664
  • 6 kV conforming to IEC 60947-1
Short-circuit protection 10 A cartridge fuse, type gG
Terminals description iso n°1
  • (13-14)NO
  • (21-22)NC
Compatibility code XCKP
Specific application compact variable
Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance 25 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
Electrical shock protection class
  • class II conforming to IEC 61140
  • class II conforming to NF C 20-030
Protective treatment TC
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 4.300 cm
Package 1 width 4.600 cm
Package 1 length 8.100 cm
Package 1 weight 72.000 g
Unit type of package 2 S02
Number of units in package 2 81
Package 2 height 15 cm
Package 2 width 30 cm
Package 2 length 40 cm
Package 2 weight 6.360 kg
Sustainable packaging No
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard No
Packaging without single use plastic No
Scip number 4e7fad22-cb90-485e-b0d8-6dd3cec617cd
End of life manual availability ENVEOLI110603EN
Take-back No
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Handout

  • eTechPub

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.