Browse all
Browse all

Harmony Timer Relays Modular timing relay 8A, 1CO, 0,1s..100h, asymmetrical flashing, 12V AC DC

Home ProductsIndustrialHarmonyModular timing relay

Harmony Timer Relays Modular timing relay 8A, 1CO, 0,1s..100h, asymmetrical flashing, 12V AC DC

Item Number: RE17RLJU

Datasheet

Product Dimensions

Width icon

Width17.5 mm

Height icon

Height90 mm

Depth icon

Depth72 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product Harmony Timer Relays
Product or component type modular timing relay

Physical

Width 17.5 mm
Connections - terminals screw connectors
[in] rated current 5 A
Height 90 mm
Depth 72 mm
Control type selector switch front panel
Connections - terminals
  • screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
  • screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
  • screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Electrical durability 100000 cycles (8 A at 250 V AC maximum) for resistive load
Mechanical durability 10000000 cycles
Marking CE
Mounting position any position in relation to normal vertical mounting plane
Mounting support 35 mm DIN rail conforming to IEC 60715
Local signalling
  • LED indicator for on steady: relay energised, no timing in progress
  • LED indicator for flashing: timing in progress 80 % ON and 20 % OFF
Function available
  • L- Asymmetrical flashing relay (starting pulse-off)-1 C/O
  • Li- Asymmetrical flashing relay (starting pulse-on)-1 C/O
Net weight 0.07 kg
Control type without test button
Standards
  • 2006/95/EC
  • 2004/108/EC
  • IEC 61000-6-4
  • IEC 61812-1
  • IEC 61000-6-3
  • IEC 61000-6-2
  • IEC 61000-6-1
Product certifications
  • CSA
  • cULus
  • GL
Ambient air temperature for storage -30...60 °C
Ambient air temperature for operation -20...60 °C
Ip degree of protection
  • IP20 (terminal block) conforming to IEC 60529
  • IP40 (housing) conforming to IEC 60529
  • IP50 (front panel) conforming to IEC 60529
Relative humidity 93 % without condensation conforming to IEC 60068...2-30
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP1211017EN
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation X
Eu rohs directive Compliant By Exemption
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Material

Contacts material cadmium free

Others

Legacy weee scope Out
Average percentage of recycled plastic content 0 %
Package 2 bare product quantity 40
Package 1 bare product quantity 1
At least in Europe
Warranty duration(in months) bmecat 18
Weee label No
Discrete output type relay
Device short name RE17R
Time delay type asymmetrical flashing
Time delay range
  • 6...60 min
  • 1...10 h
  • 6...60 s
  • 1...10 s
  • 10...100 h
  • 0.1...1 s
  • 1...10 min
Nominal output current 8 A
[uc] control circuit voltage 12 V
Output type relay
Contacts type and composition 1 C/O
[us] rated supply voltage 12 V AC/DC 50/60 Hz
Voltage range 0.9...1.2 Us
Supply frequency 50...60 Hz +/- 5 %
Input voltage 5 V
Tightening torque 0.6...1 N.m conforming to IEC 60947...1
Housing material polycarbonate
Repeat accuracy +/- 0.5 % conforming to IEC 61812-1
Temperature drift +/- 0.05 %/°C
Voltage drift +/- 0.2 %/V
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay type
  • asymmetrical flashing - L- Asymmetrical flashing relay (starting pulse-off)
  • asymmetrical flashing - Li- Asymmetrical flashing relay (starting pulse-on)
Impulse duration
  • 100 ms with load in parallel typical
  • 30 ms typical
Reset time 120 ms on de-energisation typical
On-load factor 100 %
Power consumption in va 0.7 VA at 12 V AC
Maximum power consumption in w 0.5 W at 12 V DC
Minimum switching current 10 mA at 5 V DC
Maximum switching current 8 A AC/DC
Maximum switching voltage 250 V AC
Breaking capacity 2000 VA
Operating rate in hz 10 Hz
Dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
[uimp] rated impulse withstand voltage 5 kV during 1.2/50 µs
Maximum delay response 100 ms
Creepage distance 4 kV/3 conforming to IEC 60664-1
Safety reliability data
  • B10d = 270000
  • MTTFd = 296.8 years
Number of functions 2
Time delay type L, Li
Functionality asymmetrical flashing timer
Compatibility code RE17
Immunity to microbreaks 20 ms
Vibration resistance 20 m/s² (f= 10-150 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Electromagnetic compatibility
  • electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
  • electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
  • susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
  • electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
  • electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
  • 1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
  • 1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
  • conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
  • voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
  • voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
  • conducted and radiated emissions: , class B, conforming to EN 55022
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 2.700 cm
Package 1 width 7.800 cm
Package 1 length 9.600 cm
Package 1 weight 80.000 g
Unit type of package 2 S02
Number of units in package 2 40
Package 2 height 15.000 cm
Package 2 width 30.000 cm
Package 2 length 40.000 cm
Package 2 weight 3.509 kg
Total lifecycle carbon footprint 19 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 1.5565700314205309
Carbon footprint of the manufacturing phase [a1 to a3] 2 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.06002881841570492
Carbon footprint of the distribution phase [a4] 0.1 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.0005717838897834867
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 16.982933798509755
Carbon footprint of the use phase [b2, b3, b4, b6] 17 kg CO2 eq.
Sustainable packaging Yes
Carbon footprint of the end-of-life phase [c1 to c4] 0.17936841389121552
Carbon footprint of the end-of-life phase [c1 to c4] 0.2 kg CO2 eq.
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 18.77947284612699
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
Scip number 7bdc2711-0ad2-427c-8ece-532c5e9f09d7
China rohs label 5
End of life manual availability ENVEOLI121113EN
Take-back No
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Environmental Disclosure

  • End of Life Manual

  • Installation Instruction

  • Technical illustration

  • Certificates (MSDS)

  • eTechPub

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.