Browse all
Browse all

Harmony XALD XALK Control station plastic, dark grey, 1 red pilot light/1 green flush I/1 red flush O push-buttons, Ø22 , spring return

Harmony XALD XALK Control station plastic, dark grey, 1 red pilot light/1 green flush I/1 red flush O push-buttons, Ø22 , spring return

Item Number: XALD363M

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product Harmony XALD
Product or component type complete control station
Product destination for XB5 Ø 22 mm control and signalling units
Warranty 18 months

Physical

Cable entry
  • 2 knock-outs for cable entry, clamping capacity: 14-14 mm
  • 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12-12 mm
Net weight 0.261 kg
Mechanical durability 10000000 cycles
Connections - terminals
  • screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1
  • screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1
[ie] rated operational current
  • 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1
  • 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1
  • 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1
  • 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1
  • 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1
  • 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1
Electrical durability
  • 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
  • 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
  • 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
  • 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
  • 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Ambient air temperature for storage -40...70 °C
Ambient air temperature for operation -40...70 °C
Ip degree of protection
  • IP66 conforming to IEC 60529
  • IP67
  • IP69
  • IP69K
Ik degree of protection IK05 conforming to IEC 62262
Standards
  • IEC 60947-1
  • IEC 60947-5-4
  • JIS C8201-5-1
  • CSA C22.2 No 14
  • IEC 60947-5-5
  • IEC 60947-5-1
  • UL 508
  • JIS C8201-1
Ip degree of protection IP66/IP67/IP69/IP69K
Reach free of svhc Yes
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP2506022EN
Reach regulation Free of Substances of Very High Concern above the threshold
China rohs regulation X
Eu rohs directive Compliant By Exemption
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Material

Material polycarbonate
Contacts material silver alloy (Ag/Ni)

Others

Legacy weee scope In
Package 1 bare product quantity 1
Average percentage of recycled plastic content 0 %
At least in Europe
Warranty duration(in months) bmecat 18
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Device short name XALD
Control station application Start-Stop function
Colour of base of enclosure light grey (RAL 7035)
Colour of cover dark grey (RAL 7016)
Operator profile 2 flush push-buttons - 1 central pilot light
Operators description green ''I'' 1 NO - red ''O'' 1 NC
Control station composition
  • 1 flush push-button, green 1 NO I marking
  • 1 flush push-button, red 1 NC O marking
  • 1 pilot light
Marking location marking on push-button
Contact operation slow-break
Light source integrated and protected LED
Light source colour red
[us] rated supply voltage 230 V AC
Ac control voltage 50 hz 230 V
Ac control voltage 60 hz 230 V
Dc control voltage 125...600 V
Resistance to high pressure washer 7000000 Pa at 55 °C, distance : 0.1 m
Number of command positions 2
Number of indicator lights 1
Colour of marking
  • white marking when green, red or black caps
  • black marking when white caps
Number of push buttons 2
Positive opening with conforming to IEC 60947-5-1 appendix K
Operating travel
  • 1.5 mm (NC changing electrical state)
  • 2.6 mm (NO changing electrical state)
  • 4.3 mm (total travel)
Operating force
  • 3.5 N NC changing electrical state
  • 3.8 N NO changing electrical state
Number of selector switches 0
Tightening torque 0.8...1.2 N.m conforming to IEC 60947...1
Shape of screw head
  • cross compatible with Philips no 1 screwdriver
  • cross compatible with pozidriv No 1 screwdriver
  • slotted compatible with flat Ø 4 mm screwdriver
  • slotted compatible with flat Ø 5.5 mm screwdriver
Number of key switches 0
Short-circuit protection 10 A cartridge fuse type gG conforming to IEC 60947-5-1
[ith] conventional free air thermal current 10 A conforming to IEC 60947-5-1
[ui] rated insulation voltage 600 V (pollution degree 3) conforming to IEC 60947-1
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Number of mushroom-shaped push-buttons 0
Electrical reliability
  • λ < 10exp(-6) at 5 V, 1 mA conforming to IEC 60947-5-4
  • λ < 10exp(-8) at 17 V, 5 mA conforming to IEC 60947-5-4
Signalling type steady
Supply voltage limits 195...264 V AC
Current consumption 14 mA
Number of contacts as normally closed contact 1
Service life 100000 h at rated voltage and 25 °C
Surge withstand 1 kV conforming to IEC 61000-4-5
Number of contacts as normally open contact 1
Compatibility code XALD
Number of contacts as change-over contact 0
Housing material plastic
Housing colour grey
Colour of cover dark grey
Protective treatment TH
Overvoltage category class II conforming to IEC 60536
Nema degree of protection
  • NEMA 13
  • NEMA 4X
Vibration resistance 5 gn (f= 12-500 Hz) conforming to IEC 60068-2-6
Shock resistance
  • 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
  • 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Resistance to fast transients 2 kV conforming to IEC 61000-4-4
Resistance to electromagnetic fields 10 V/m conforming to IEC 61000-4-3
Resistance to electrostatic discharge
  • 6 kV on contact (on metal parts) conforming to IEC 61000-4-2
  • 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
Electromagnetic emission class B conforming to IEC 55011
Nema degree of protection NEMA 4X/13
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 7.1 cm
Package 1 width 9.8 cm
Package 1 length 14.1 cm
Package 1 weight 289 g
Unit type of package 2 S03
Number of units in package 2 25
Package 2 height 30 cm
Package 2 width 30 cm
Package 2 length 40 cm
Package 2 weight 7.713 kg
Unit type of package 3 P06
Number of units in package 3 200
Package 3 height 77 cm
Package 3 width 60 cm
Package 3 length 80 cm
Package 3 weight 70.916 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 135 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 1.8810019087
Carbon footprint of the manufacturing phase [a1 to a3] 2 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.037288289
Carbon footprint of the distribution phase [a4] 0 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.0017432984
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 133.1678742009
Carbon footprint of the use phase [b2, b3, b4, b6] 133 kg CO2 eq.
Sustainable packaging Yes
Carbon footprint of the end-of-life phase [c1 to c4] 0.0545711588
Carbon footprint of the end-of-life phase [c1 to c4] 0.1 kg CO2 eq.
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 135.1424788559
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
Scip number 2f798476-9490-459d-81bd-f7dac4bf68c8
China rohs label 7
End of life manual availability ENVEOLI2506022EN
Take-back No
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Environmental Disclosure

  • End of Life Manual

  • Technical illustration

  • Declaration of Conformity

  • Certificates (MSDS)

  • eTechPub

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.