Altistart 22 Soft starter ATS22 control 220V power 230V(15kW)/400...440V(30kW)
Item Number: ATS22D62Q
Datasheet
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| - | |||
| - | |||
| - |
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| 1 | CAR | 3606480167218 | - |
Specifications
Design
| Range of product | Altistart 22 |
|---|---|
| Product or component type | soft starter |
| Product destination | asynchronous motors |
| Warranty | 18 months |
Physical
| Ip degree of protection | IP20 |
|---|---|
| Function available | internal bypass |
| Output current | 0.4...1 Icl adjustable |
| Communication port protocol | Modbus |
| Connector type | 1 RJ45 |
| Protection type |
|
| Marking | CE |
| Height | 295 mm |
| Width | 145 mm |
| Depth | 207 mm |
| Net weight | 12 kg |
| Standards | IEC 60947-4-2 |
| Product certifications |
|
| Relative humidity | 0...95 % without condensation or dripping water conforming to IEC 60068...2-3 |
| Ambient air temperature for operation |
|
| Ambient air temperature for storage | -25...70 °C |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP100403EN |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | X |
| Eu rohs directive | Compliant By Exemption |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Others
| Life cycle assessment data | No |
|---|---|
| If one of the deliverables is not relevant please give the reason | End of commercialization (planned, announced or effective) |
| Substance regulation data deliverable | Yes |
| Legacy weee scope | In |
| Package 1 bare product quantity | 1 |
| Average percentage of recycled plastic content | 0 % |
| At least in Europe | |
| Warranty duration(in months) bmecat | 18 |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Product specific application | pumps and fans |
| Component name | ATS22 |
| Network number of phases | 3 phases |
| [us] rated supply voltage | 230...440 V - 15...10 % |
| Motor power kw |
|
| Factory setting current | 57 A |
| Power dissipation in w | 59 W for standard applications |
| Utilisation category | AC-53A |
| Type of start | start with torque control (current limited to 3.5 In) |
| Icl starter rating | 62 A for connection in the motor supply line for standard applications |
| Assembly style | with heat sink |
| Supply voltage limits | 195...484 V |
| Supply frequency | 50...60 Hz - 10...10 % |
| Network frequency | 45...66 Hz |
| Device connection |
|
| [uc] control circuit voltage | 230 V - 15...10 % 50/60 Hz |
| Control circuit consumption | 20 W |
| Discrete output number | 2 |
| Discrete output type |
|
| Minimum switching current | 100 mA at 12 V DC (relay outputs) |
| Maximum switching current |
|
| Discrete input number | 3 |
| Discrete input type | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm |
| Discrete input voltage | 24 V <= 30 V |
| Discrete input logic | positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
| Ptc probe input | 750 Ohm |
| Communication data link | serial |
| Physical interface | RS485 multidrop |
| Transmission rate | 4800, 9600 or 19200 bps |
| Installed device | 31 |
| Type of cooling | forced convection |
| Operating position | vertical +/- 10 degree |
| Power range |
|
| Motor starter type | soft starter |
| Electromagnetic compatibility |
|
| Vibration resistance |
|
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Noise level | 45 dB |
| Pollution degree | level 2 conforming to IEC 60664-1 |
| Operating altitude |
|
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 31.0 cm |
| Package 1 width | 23.5 cm |
| Package 1 length | 36.0 cm |
| Package 1 weight | 8.262 kg |
| Unit type of package 2 | P06 |
| Number of units in package 2 | 6 |
| Package 2 height | 73.5 cm |
| Package 2 width | 80.0 cm |
| Package 2 length | 60.0 cm |
| Package 2 weight | 64.0 kg |
| Green premium status for reporting | Green Premium product |
| Sustainable packaging | No |
| Take-back | No |
| Product contributes to saved and avoided emissions | No |
| Removable battery | N/A |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | No |
| Packaging without single use plastic | No |
| Scip number | 7f28cbce-306d-4c94-ba04-b506c5522d63 |
| China rohs label | 5 |
| End of life manual availability | ENVEOLI110803EN |
| Take-back | No |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) | 18 |
Documents & downloads
-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
End of Life Manual
-
Installation Instruction
-
Operating Manuals
-
Certificates (MSDS)
-
Declaration of Conformity
-
eTechPub
-
Declaration of Conformity (Sustainability)
-
Software - Data Library
Seismic Qualification of Enclosed Drives and Soft Starters Instruction Bulletin
VERSION
1.0
DATE
01 Mar 2024
REVISION
1.0
Altistart 22 Soft Starters in Motor Control Centers - Installation Instructions
VERSION
1.1
DATE
21 Feb 2024
REVISION
1.1
Enclosed Altistart 22 Solid State Reduced Voltage Combination Motor Controller Instruction Bulletin
VERSION
1.1
DATE
30 Oct 2023
REVISION
1.1
ATS22 - Quick Start guide
VERSION
4.0
DATE
30 Oct 2023
REVISION
4.0
ATS22 to ATS430 Modernization Manual
VERSION
1.0
DATE
23 Sep 2025
REVISION
1.0
1) ATS22 - Quick Start ANNEX for UL 508 market
VERSION
6.1
DATE
06 May 2024
REVISION
6.1
ATS22 Soft Starter User Manual
VERSION
4.1
DATE
30 Oct 2023
REVISION
4.1
ATS22 ABS BATAM CERTIFICATE
VERSION
1.0
DATE
04 Mar 2026
REVISION
1.0
KCC Certificate for ATS22D62Q and equivalent models
VERSION
1.0
DATE
09 Feb 2026
REVISION
1.0
ATS22 CSA CERTIFICATE
VERSION
2.0
DATE
14 Jan 2026
REVISION
2.0
ATS490 & ATS430 EAC Certificate
VERSION
1.0
DATE
04 Dec 2025
REVISION
1.0
ATS22D62-D88 CCC CERTIFICATE
VERSION
2.0
DATE
13 Nov 2024
REVISION
2.0
ATS22 UL CERTIFICATE
VERSION
1.0
DATE
06 Oct 2022
REVISION
1.0
ATS22D62Q China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q China RoHS Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
ATS22D62Q REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
Related products
DISCONTINUED
LC1D65AP7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 230VAC 50/60Hz coil
DISCONTINUED
LC1D65AB7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 24VAC 50/60Hz coil
DISCONTINUED
LC1D65AE7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 48VAC 50/60Hz coil
DISCONTINUED
LC1D65AF7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 110VAC 50/60Hz coil
DISCONTINUED
LC1D65AM7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 220VAC 50/60Hz coil
DISCONTINUED
LC1D65AV7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 400VAC 50/60Hz coil
DISCONTINUED
LC1D65ABD
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 24VDC standard coil
DISCONTINUED
LC1D65AED
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3, 0 to 440V, 65A, 48VDC standard coil
DISCONTINUED
LC1D65AP7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 230VAC 50/60Hz coil
DISCONTINUED
LC1D65AB7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 24VAC 50/60Hz coil
DISCONTINUED
LC1D65AE7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 48VAC 50/60Hz coil
DISCONTINUED
LC1D65AF7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 110VAC 50/60Hz coil
DISCONTINUED
LC1D65AM7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 220VAC 50/60Hz coil
DISCONTINUED
LC1D65AV7
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 400VAC 50/60Hz coil
DISCONTINUED
LC1D65ABD
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 65A, 24VDC standard coil
DISCONTINUED
LC1D65AED
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3, 0 to 440V, 65A, 48VDC standard coil
Recently viewed
DISCONTINUED
ATS22D62Q
Altistart 22 Soft starter
ATS22 control 220V power 230V(15kW)/400...440V(30kW)