Socket Sw Vert Twin 10A 250V

Clipsal Iconic - Twin Switch Socket Outlet, Vertical Mount, 250V, 10A

Catalogue Number: 3025V
Socket Sw Vert Twin 10A 250V
Colour: Vivid White
Colour: Per UOM Std.
  • Vivid White 1 PCE
Added to cart

Specifications

hide show
Range
Clipsal Iconic
Product or component type
switched socket
Device presentation
complete product
Outlet poles configuration
2P + E with shutter
Device mounting
flush
Number of power socket outlets
2
Number of rocker
2
Range compatibility
Outlet standard
Australian
Outlet standard description
with earthing contact
Outlet standard
Australian/New Zealand
Ground lug position
straight 180° position
Fixing mode
by screw
Installation direction
vertical
Colour tint
vivid white (VW)
Surface finish
matt
Type of packing
polybag
Quantity per set
set of 10
Sale per indivisible quantity
1
Rated current
10 A at 250 V AC 50 Hz
Electrical durability
12000 cycles
Connections - terminals
3 screw terminals
Screwdriver shape
  • Philips No 2
  • square drive no 1 (SQ1)
    • Clamping connection capacity
    • 1 x 2.5...4 x 2.5 mm² for rigid cable(s)
    • 1 x 2.5...4 x 2.5 mm² for stranded cable(s)
    • 1 x 2.5...4 x 2.5 mm² for flexible cable(s)
      • Wire stripping length
        16 mm
        Material
      • PC (polycarbonate): fixing frame
      • PP (polypropylene): rocker
      • POM (polyoxymethylene): shutter
      • PC (polycarbonate): cover frame
      • ABS (acrylonitrile butadiene-styrene): cover frame
        • Height
          120 mm
          Width
          78 mm
          Depth
          32 mm
          Embedding depth
          24 mm
          Net weight
          0.116 kg
          Ambient air temperature for operation
          0-45 °C
          Relative humidity
          10-95 %
          Standards
          AS/NZS 3112
          Product certifications
          RCM
          Sustainable offer status
          Green Premium product
          EU RoHS Directive
          Compliant
          Toxic heavy metal free
          Yes
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
           Pro-active China RoHS declaration (out of China RoHS legal scope)
          Environmental Disclosure
          ENVPEP120506EN
          Circularity Profile
          N/A

          Documents & downloads

          hide show
          Filter items
          • All

          • Product Brochures

          • Technical Data Catalogues

          • Technical Leaflet

          • Product Environmental

          • Installation Instruction

          • Operating Manuals

          • Certificates (MSDS)

          Frequently Asked Questions

          hide show

          What is screwdriver head size for Iconic 3025 GPO?

          The screwdriver head size for Iconic 3025 GPO is either size PH2 or SH1 can be used.

          Is there an IP66 rated 2 gang vertical outlet in 2000 range?

          No there is no IP66 rated outlet in the 2000 series. For IP66 outlets the 56 Series would be the best option
          For Clipsal 2000 series information click this link https://www.clipsal.com/Trade/search-results?q=2025v

          For Clipsal 56 Series please click this link https://www.clipsal.com/Trade/search-results?q=56c310

          Do the switches in Iconic switched socket outlet have LED indicators, example 3025?

          There are no LED indicators on the switches in Iconic switched socket outlet. The switches on the outlet have green markings so you know when it is switched ON.

          For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3025



           

          Is grid only available for part number 4025?

          No. Unfortunately, Grid is not available for 4025.

          What is replacement cover for C2025V?

          The replacement cover for C2025V is C2025VC2.

          What is the part number for the grid only in the Iconic range double gpo ?

          The grid 3025VXUAG is suitable for both the 3025V and 3025VXA setup ( the 2 units share a common grid )

          Is the Clipal 30FAV a solder connector

          They are F connectors on the back.  Clipsal do not do solder on the back of RCA's

          Can the 30FAV Red and White be purchased as individual parts

          No they come in the pack of 30FAVRWY so red, white and yellow combination

          What is the mounting block for 4025?

          The part name is as follows: 449B-WE

          L1JCN - C2025V - what is the correct cover plate as old & new

          C2025VC-WE (old Style)
          C2025VC2-WE (new style

          Is there a product data sheet for a 2025?

          Yes there is. Please see the attached PDF document.
          Some of the key features are:
          • 10A Rated
          • 250V Rated
          • Double Outlet
          • 2000 Series
          • Variety of colours
          For further information please visit Trade - Clipsal by Schneider Electric


           

          Is Grid plate only available for 4025?

          No its available as Grid & Cover.

          Is Saturn cover available for 4025?

          Yes. It is available and the part number is 4025C.

          What is the dimensions of part number 4025?

          Dimensions for part number 4025 are 116mm(W) 75mm (H) 15mm

          For further information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=4025

          Is the saturn single GPO (4015) available with extra switches?

          Not available. We have 4025XA - double GPO with extra removable switch  and 4025X - double GPO with extra non-removable switch

          What is the cover for a 4025X?

          The part number for the cover to suit the 4025X is a 4025C.

          Is there a red double horizontal socket available without the RCD, Neon, or Circ ID in the Medliec range?

          Yes, the 2025, double horizontal socket 250V 10A is available in red. Use the code 2025-RD.
           

          Do you have a double pole version of the 2025L?

          No, unfortunately we do not have a 2025L that is double pole.
          However we can offer the 25DL-WE which is a double pole double outlet with round earth pins.

          What is the part number for the ICONIC night walk?

          The part number for the ICONIC night walk is a 3025NW. which is only the cover/sensor light. You will also need the grid which is a 3025G.

          What is a 2000 Series power point?

          The 2000 Series power point is a 2025.
          • 10A Double Power Point
          • 240V AC
          • 2000 Series
          For further information please visit: https://www.clipsal.com/Trade/Products/ProductDetail?catno=2025

          User-added image

          What is part number for cover to suit Saturn 4025?

          The part number for cover is 4025C.

          What is the part number for a wall box for the Saturn range double GPO , 4025?

          The part number for a wall box for the Saturn range double GPO , 4025 is - 157/1PRM

          For further information , visit link below:-
          https://www.clipsal.com/Trade/search-results?q=157/1PRM
          User-added image
           

          What is the part number of the cover to suit 2025?

          The part number is 2000-xx
          (xx is the color code)

          Please click this link for further information
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=2000

          User-added image

          Can you get the 4025X with a 35A mechanism?

          No unfortunately that particular switch only comes in 10A and is not removable.

          However, the 4025XA has a removable mechanism and can be replaced with the mechanism 60R32 which is a 32A mechanism.

          Some of the key features are:

          • Saturn Series
          • 10A
          • 250V
          • Extra removable switch
          • Various colours available

          For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4025XA



           

          Do Clipsal do a vertical single or double GPO in the Slimline range?

          No , if customer wants vertical GPO , they will have to use 2000 series , 2025V, or Classic series , C2025V

          For further information , visit links below:-
          https://www.clipsal.com/Trade/search-results?q=2025V
          https://www.clipsal.com/Trade/search-results?q=C2025V
          User-added image

          Do Saturn series power outlets have indicators on the switch mechanism?

          Saturn series power outlets (example 4025) do not have led indicators on the switch mechanism. Saturn series wall switches are available with the option of having blue LED indicators on the switch mechanism.
          For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000296.pdf
           

          What is the alternate / replacement plates for the old Clipsal C2025VC in black

          C2025VC-BK is no longer available.  That would be for the C2025VS plates.  If the customer has a C2025V socket outlet 
          he could order the C2025VC2-BK covers as indent from Australia.

          Version 2 NetBotz ​0-5V sensor on Sensor Pod 120 reports double the actual voltage in Advanced View


          Issue:
          0-5V sensors connected to the NetBotz Sensor Pod 120 with the NetBotz 0-5V Sensor Cable (NBAC0231) report double the actual voltage in Botzware and the Advanced View.

          Product Line:
          NetBotz

          Environment:
          Advanced View v4.3 and 4.4
          NetBotz 0-5V Cable (NBAC0231)

          Cause:
          Firmware updates affected the performance of the NetBotz 0-5V Cable (NBAC0231).

          Resolution:
          There is no resolution at this time.

          What is the part number of the fixed Front Connection snap-in nuts for the Compact NS100 to 630 circuit-breakers.?

          The part number of a set of 12 fixed front connection snap-in nuts is:

          29234 for Compact NS100.
          30554 for Compact NS160... 250.

          These parts are not available for Compact NS400 to 630.

          What is the part number for a slimline double GPO with an extra , removable , switch mech?

          The part number for a slimline double GPO with an extra , removable , switch mech is - SC2025XA
          But because Slimline is no longer available Iconic 3025XA (PDL395X) is the next slimest option, or Classic C2025XA if you prefer the Slimline look.

          Part number for Saturn cover for double outlet?

          The part number of a cover for a 4025 is 4025C.

          Some of the key features are:
          • Cover suit both 4025 and 4025X switched sockets
          • Double power outlet 

          For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4025C

           

          What does 3F25 fault mean on a PV100-208 or 3F25\3F26 on a PV225-208?

          Issue:
          Unit faulted on 3F25 or 3F26

          Product Line:
          PV100-208 or PV225-208

          Environment:

          Cause:
          No LED on any of the three phases of the driver board

          Resolution:
          The power supply, PS1, provides 15VDC to the driver board. If the power supply is bad, no LED will be present. Check the power supply fuses F9 and F10 to see if they are blown or not. If blown, replace them and see if the fault can be cleared. If the replacement did not fix the issue or the fuses are blown again, call 866-519-1470 and select option 3 and 3 to open a case.
           

          M580 SD memory card format procedure

          M580 CPU SD memory card format procedure
          1. Connect to M580 and make sure the Unity project is “Equal”, “Run” and “Built”
          2. Stop the PLC
          3. Open SD card door and make sure LED is ON
          4. Open the “Animation Table” Window
          5. Add system word %SW93.0 and %SW93.1
          6. Turn on the “Modification” button
          7. Enter value “1” for %SW93.0
          8. (This will start the format of the SD card then that value will change back to “0” and the value of %SW93.1 will go from “0” to “1” to indicate the format has completed successfully), (Formatting a standard SD card takes about 30-50 seconds)
          9. When completed enter value of “0” for both %SW93.0 and %SW93.1
          10. Start PLC

          Advantys STB Module Backplane Current Consumption

          Release Notice

          The purpose of this Resolution is to inform Advantys users of changes in the I/O modules current consumption specifications.

          •  

          Goals and Symptoms

          Some of the publications have incorrect 5.25v backplane current consumption values specified.

          Facts and Changes

          The following documents are affected:

          1. The online Help in Advantys Configuration Software versions 1.2 or less.
          2. The Advantys STB Hardware Components Reference Guide, 890USE17200, version 3.0 and less.

          The Resource Analysis option in Advantys Configuration Software version 1.2 contains the correct values.

          Causes and Fixes

          The attached document lists the Advantys modules and the current that is either supplied or consumed by the device.

          Attachments

          (Removed File URL: 165318_625E/Advantys_Module_power10-8-04.doc)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/db2b191674d98e9885256f270050bc0d/fl_block_5/0.1364?OpenElement&FieldElemFormat=gif)


          Legacy KB System (APS) Data: RESL165318 V2.0, Originally authored by on , Last Edited by on
          Related ranges: Advantys STB

          How to determine the Date of Manufacture for a PM800 Series Meters

          Issue:
          A user may need to determine the manufacture date of a PM800 series meter

          Product Line:
          PM800 series meters

          Environment:
          Manufacturing Information

          Cause:
          The date of manufacture is required by the RMA procedure

          Resolution:
          *Warning: Installation and maintenance of this device should only be performed by qualified, competent personnel that have appropriate training and experience with high voltage and current devices. Failure to follow the instructions / warnings in the Meter Installation Guide can result in permanent damage to the meter, severe injury or death. 

          There are three ways to determine the Date Of Manufacture (DOM) of a PM800 series meter.

          1. Front Display
          From the front display of the meter, Select "Diagnostic -> Meter Information -> DOM"
          You can read the "DOM" registers from the meter:

          2. Register Reads
          Three registers in the meter contain the DOM information starting at 3019. You can use Modbus tester or any Modbus register reading tool to read three registers (3019, 3020, and 3021). To download Modbus Tester, click on article FA180037

          Please use the following template for interpretation:
           
          Register 3019:Hi Byte = Month (1 - 12) ; Register 0:Lo Byte = Day (1 - 31)
          Register 3020 :Hi Byte = Year (0 - 199)   ; Register 1:Lo Byte = Hour (0 - 23)
          Register 3021 :Hi Byte = Minute (0 - 59) ; Register 2:Lo Byte = Second (0 - 59)

          3. Product Information Label
          Caution: Take all necessary precautions when exposing live energized circuits
           
          There is a product information label located on the side of the meter body that contains the serial number and date of manufacture for the meter.