Acti9 iC60H3 Residual current breaker with overcurrent protection (RCBO) 3P+Ns, D Curve, 10A, 30mA, A type, 10000A

Home ProductsCircuit ProtectionActi9Residual current breaker with overcurrent protection (RCBO)

Acti9 iC60H3 Residual current breaker with overcurrent protection (RCBO) 3P+Ns, D Curve, 10A, 30mA, A type, 10000A

Item Number: A9DD1910

Datasheet

Product Dimensions

Width icon

Width54 mm

Height icon

Height112 mm

Depth icon

Depth77.2 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range Acti9
Product or component type residual current breaker with overcurrent protection (RCBO)

Physical

[in] rated current 10 A at 30 °C
[ue] rated operational voltage 400/415 V
Control type toggle
Local signalling ON/OFF indication
Mounting mode clip-on
Mounting support
  • DIN rail
  • chassis
Height 112 mm
Width 54 mm
Depth 77.2 mm
Net weight 462 g
Mechanical durability 20000 cycles
Electrical durability 5000 cycles
Connections - terminals
  • screw clamp terminal (top) 1-25 mm² rigid without cable end
  • screw clamp terminal (top) 1-16 mm² flexible
Wire stripping length
  • power circuit: 11 mm for bottom connection
  • power circuit: 14 mm for top connection
Standards
  • AS/NZS 61009.1
  • IEC 61009-1
  • IEC 61009-2-2
Ip degree of protection IP20
Relative humidity 95 % at 55 °C
Ambient air temperature for operation -5...60 °C
Ambient air temperature for storage -25...70 °C
Reach free of svhc Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP2308033EN
Reach regulation Free of Substances of Very High Concern above the threshold
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant

Others

Legacy weee scope In
Package 1 bare product quantity 1
Package 2 bare product quantity 16
Average percentage of recycled plastic content 0 %
Outside of Europe
Warranty duration(in months) bmecat 18
Weee label N/A
Weee applicability Finished product
Circuit breaker application distribution
Product name Acti9 iC60 RCBO
Device short name iC60H3 RCBO
Poles description 3P + Ns
Earthing system TN
Curve code D
Earth-leakage sensitivity 30 mA
Breaking capacity 10000 A Icn at 400/415 V
Neutral position left
Number of protected poles 3
Device location in system outgoer
Network frequency 50/60 Hz
Network type AC
Trip unit technology thermal-magnetic
Residual current tripping technology voltage dependent
Earth-leakage protection time delay instantaneous
Earth-leakage protection class type A
[icw] rated short-time withstand current Icw: 250 A during 8/20 µs impulse withstand
[ics] rated service breaking capacity 7500 A
Limitation class 3
[ui] rated insulation voltage 500 V
[uimp] rated impulse withstand voltage 4 kV
Surge current 250 A
Suitability for isolation yes conforming to IEC 61009-1
Comb busbar and distribution block compatibility YES
9 mm pitches 6
Provision for padlocking
  • padlockable with padlock Ø 4 mm
  • lead seal
Locking options description ON/OFF locking facilities
Tightening torque
  • power circuit: 2.5...2.5 N.m top
  • power circuit: 2.5...2.5 N.m bottom
Earth-leakage protection integrated
Test button operating voltage 260...457 V
Operating voltage earthleakage protection 150...457 V
Grid distance 45 mm
Locking options description handle sealable with cable diameter 1.4mm in OFF or ON position
Tropicalisation 2
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 12.7 cm
Package 1 width 6.6 cm
Package 1 length 9 cm
Package 1 weight 539 g
Unit type of package 2 S02
Number of units in package 2 16
Package 2 height 15 cm
Package 2 width 30 cm
Package 2 length 40 cm
Package 2 weight 9.376 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 6 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 4.065593015
Carbon footprint of the manufacturing phase [a1 to a3] 4 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.037270577
Carbon footprint of the distribution phase [a4] 0 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.065751401
Carbon footprint of the installation phase [a5] 0.1 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 0.923188499
Carbon footprint of the use phase [b2, b3, b4, b6] 0.9 kg CO2 eq.
Sustainable packaging Yes
Carbon footprint of the end-of-life phase [c1 to c4] 1.056123897
Carbon footprint of the end-of-life phase [c1 to c4] 1 kg CO2 eq.
Pvc free Yes
Halogen-free status Product contains halogen above thresholds
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 6.147927389
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
China rohs label 1
Halogen-free status Product contains halogen above thresholds
Pvc free Yes
End of life manual availability ENVEOLI2308033EN
Take-back No
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Environmental Disclosure

  • End of Life Manual

  • Installation Instruction

  • Declaration of Conformity

  • Certificates (MSDS)

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.