SpaceLogic C-Bus Dimmer 8 channel, 1A per channel, DIN rail mount, inbuilt switchable C-Bus power supply, white

SpaceLogic C-Bus Dimmer 8 channel, 1A per channel, DIN rail mount, inbuilt switchable C-Bus power supply, white

Item Number: 5508D1D

Datasheet

Product Dimensions

Width icon

Width216 mm

Height icon

Height92 mm

Depth icon

Depth63 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

SpaceLogic C-Bus

Product brand

Schneider Electric

Product or component type

dimmer

Device application

light control

Physical

Device presentation

complete device

Provided equipment

1 400 mm patch cable

Load type

  • dimmable LED
  • halogen lamp
  • halogen lamp with standard electronic transformer
  • halogen lamp with standard ferromagnetic transformer
  • incandescent lamps

Dimmer type

  • trailing edge
  • leading edge

Communication network type

C-Bus

Number of channels

8

Connector type

2 RJ45 connectors for C-Bus

Device mounting

DIN rail

Mounting support

DIN rail

Width

216 mm

Height

92 mm

Depth

63 mm

Net weight

0.844 kg

Ambient air temperature for operation

-5...55 °C

Ambient air temperature for storage

-20...60 °C

Relative humidity

10...93 % non-condensing

Standards

  • REACH
  • RoHS

Product certifications

  • RCM
  • UKCA
  • CE

Reach free of svhc

Yes

Rohs exemption information

Yes

Environmental disclosure

ENVPEP2310006EN

Eu rohs directive

Compliant with Exemptions

Reach regulation

Free of Substances of Very High Concern above the threshold

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Others

Package 2 bare product quantity

10

Average percentage of recycled plastic content

0 %

Package 1 bare product quantity

1

Legacy weee scope

In

Weee applicability

Finished product

Outside of Europe

Weee label

N/A

Load current

  • 1 A per channel
  • 8 A per unit

Main colour tint

white

Network frequency

  • 47...53 Hz
  • 57...63 Hz

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

9.7 cm

Package 1 width

10.1 cm

Package 1 length

22.3 cm

Package 1 weight

844 g

Unit type of package 2

CAR

Number of units in package 2

10

Package 2 height

22.1 cm

Package 2 width

24.7 cm

Package 2 length

52.2 cm

Package 2 weight

8.65 kg

Green premium status for reporting

Green Premium product

Total lifecycle carbon footprint

363 kg CO2 eq.

Carbon footprint of the manufacturing phase [a1 to a3]

51.91745454545454

Carbon footprint of the manufacturing phase [a1 to a3]

52 kg CO2 eq.

Carbon footprint of the distribution phase [a4]

0.24748363636363635

Carbon footprint of the distribution phase [a4]

0.2 kg CO2 eq.

Carbon footprint of the installation phase [a5]

0.23029090909090907

Carbon footprint of the installation phase [a5]

0.2 kg CO2 eq.

Carbon footprint of the use phase [b2, b3, b4, b6]

309.36000000000007

Carbon footprint of the use phase [b2, b3, b4, b6]

309 kg CO2 eq.

Sustainable packaging

No

Carbon footprint of the end-of-life phase [c1 to c4]

1.1453454545454544

Carbon footprint of the end-of-life phase [c1 to c4]

1 kg CO2 eq.

Pvc free

No

Halogen-free status

Halogen free product

Silicone-free 

No

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Total lifecycle carbon footprint

362.9005745454546

Average percentage of recycled metal content

0 %

Packaging made with recycled cardboard

Yes

Packaging without single use plastic

No

Halogen-free status

Halogen free product

Pvc free

No

Silicone-free

No

End of life manual availability

ENVEOLI2310006EN

Take-back

No

Warranty (in months)

18
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Operating Manuals

  • Quick Start Guide

  • Declaration of Conformity (Sustainability)

  • Declaration of Conformity

  • Certificates (MSDS)

  • Software - Release

  • Software - Utility

Important: Some software files may need a mySchneider or Club login to download.

Frequently Asked Questions

Where to download the SpaceLogic C-Bus Commission V2.1.2?

Hide Show
Where to download the SpaceLogic C-Bus Commission V2.1.2?

Release Date: 15/01/2024
Version: V2.1.2
Reference: C-Bus-Commission_V2.1.2
C-Gate: 3.2.3 (build 1760)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10.

What’s New  
  • New C-Bus Digital Dimmer firmware released
New firmware is now available for the DIMDD4 (5504D2D) and DIMDD8 (5508D1D) C-Bus Digital Dimmer devices and is version 1.3.0. This is seen in the Firmware Updater window and is also the default firmware version when adding a new device to a network. 
 
  • Channel Dimming Mode comparison when deploying the C-Bus Digital Dimmers
As required for the C-Bus Digital Dimmer version 1.3.0 firmware, the dimming mode for each channel must be confirmed during the device installation process. The software now performs a comparison upon deployment of a C-Bus digital dimmer, checking for differences between the dimming mode set for all channels of the dimmer within the software versus the dimmer on the live network. If any differences are found, a window is then presented including the results and instructions for next steps (continue to deploy or cancel). 
 
  • Updated Custom Load Profile settings and default values (C-Bus Digital Dimmers)
The custom load profile settings and default values of the C-Bus Digital Dimmer have been updated to improve the dimmer performance for certain load types and when setting a Mains Frequency of 60 Hz. Changes apply to the following properties: Minimum Brightness and Maximum Brightness, Soft Turn On and Soft Turn Off, Kickstart Brightness and Kickstart Turn On.

Fixes
  • When performing a Transfer to or Retrieve from a C-Bus Controller, if a Level name already exists in a Lighting application, it is not counted and presented within the Duplicate count.
  • C-Bus DALI-2 Gateway keeps displaying “C-Gate Error” when extracting that was previously loaded (Full Gateway Scan required after DALI line changes).
  • Stop Identify (DALI device) was not always successful.
  • The loading of live DALI devices into the PE was not displaying the correct information.

Known Issues
  • A slight delay may be seen when switching views back and forth between the Measurement and Error applications where a large amount of data (150 items or more) exists.
  • Clicking on the Main Menu repeatedly will result in a decrease in software performance.
  • Switching projects 10 or more times will result in a decrease in software performance.
  • Measurement application values presented from the live network may not appear truncated and rounded to reasonable decimal places.  C-BUS COMMISSION RELEASE NOTES 2 
  • When transferring to a C-Bus Controller, updating a Tag Map name will create an Object if one does not exist, this can result in additional objects created in controller that were not defined in the Object List of software.

Link to download the SpaceLogic C-Bus Commission V2.1.2
https://www.se.com/nz/en/download/document/C-Bus-Commission_V2.1.2/
 

Where to download the C-Bus Toolkit 1.17.0?

Hide Show
Where to download the C-Bus Toolkit 1.17.0?

Release Date: 25/10/2023
Version: V1.17.0
Reference: C-Bus_Toolkit_V1.17.0
C-Gate: 3.2.0 (build 1674)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10, Windows 8, Windows 7.

BREAKING CHANGE
This release introduces a new version of C-Gate 3 that is incompatible with older versions of C-Gate (2.1.11 and below) and C-Bus Toolkit (1.16.4 and below).

This release adds basic support for the DIMDD4 (5504D2D) and DIMDD8 (5508D1D) dimmer devices.

Important Notes:
  • C-Gate 3 cannot co-exist on the same machine as C-Gate 2.
  • C-Bus Toolkit 1.17.0 (and above) cannot be used with C-Gate 2 (or below).
  • Once projects have been converted to the new format, they cannot be used by C-Gate 2 or below.
  • We strongly recommend creating a separate back up of projects before installing and running this release.

Link to download C-Bus Toolkit 1.17.0
https://www.se.com/au/en/download/document/C-Bus-Toolkit_V1.17.0/
 

Where to download the SpaceLogic C-Bus Commission V2.0.0?

Hide Show
Where to download the SpaceLogic C-Bus Commission V2.0.0?

Release Date: 26/10/2023
Version: V2.0.0
Reference: C-Bus-Commission_V2.0.0
C-Gate: 3.2.0 (build 1674)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10.

First Release:
The new C-Bus Commission software is built upon and includes a new version of C-Gate (C-Gate 3.2.0). The new version of C-Gate requires that updates are performed to the broader suite of C-Bus software installed on the PC including C-Bus Toolkit, plus other applications such as PICED, HomeGate, etc.

If you have C-Bus Toolkit V1.16.x or earlier currently installed on your PC, you must also install the latest release of C-Bus Toolkit (V1.17.0 or later) accompanying this release of C-Bus Commission. Both C-Bus Toolkit and C-Bus Commission software applications are bundled with C-Gate 3.2.0.

The new C-Bus Commission software offers capabilities to design a C-Bus project and incorporate the new C-Bus DALI-2 Gateway and DALI devices as well as the new C-Bus Digital Dimmer devices.

Important Notes:
This release includes support for the new project file format used by C-Gate 3.2.0. Only projects that have been successfully converted can be opened.
Once projects have been converted to the new format, they cannot be used by C-Gate 2 or below.
We strongly recommend creating a separate back up of projects before installing and running this release.

Link to download the SpaceLogic C-Bus Commission V2.0.0
https://www.se.com/au/en/download/document/C-Bus-Commission_V2.0.0/
 

Where to download the C-Bus Toolkit 1.17.2?

Hide Show
Where to download the C-Bus Toolkit 1.17.2?

Release Date: 11/01/2024
Version: V1.17.2
Reference: C-Bus_Toolkit_V1.17.2
C-Gate: 3.2.3 (build 1760)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10, Windows 8, Windows 7

Bug fix:
  • Fixed an issue in the Edit Network dialog that prevented the network from being opened or scanned when the interface type was changed from Serial to C-Bus Home Controller.
Updates to C-Gate include:
  • Support firmware version 1.3.0 of DIMDD4 (5504D2D) and DIMDD8 (5508D1D) C-Bus Digital Dimmer devices.

Link to download C-Bus Toolkit 1.17.2
https://www.se.com/au/en/download/document/C-Bus-Toolkit_V1.17.2/
 

Where to download the C-Bus Toolkit 1.17.1?

Hide Show
Where to download the C-Bus Toolkit 1.17.1?

Release Date: 08/12/2023
Version: V1.17.1
Reference: C-Bus_Toolkit_V1.17.1
C-Gate: 3.2.2 (build 1716)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10, Windows 8, Windows 7.

Bug fix:
  • Issue resolved when clicking the ‘+’ button to add a new application in the eDLT unit dialog.

Updates to C-Gate 3.2.2 include:
  • Update C-Bus DALI-2 Gateway firmware version default to version 1.7.0.
  • Device update to support C-Bus DALI-2 Gateway and DALI Device Primary Control Function.
  • Added support for C-Bus Network Devices section firmware update notification.
  • Fixed the transfer of new levels to a C-Bus Controller within existing groups.

Link to download C-Bus Toolkit 1.17.1
https://www.se.com/au/en/download/document/C-Bus-Toolkit_V1.17.1/
 

Is the Spacelogic Dimmer/Relay 200mA inbuilt Power supply enabled by default?

Hide Show

By default, the Spacelogic Dimmer/Relay inbuilt 200mA C-Bus Power Supply is disabled. It can be enabled by using the Channel Indicator buttons on the front of the unit.

How to change the channel mode Leading/Trailing on the C-Bus Digital dimmer 5508D1D/5504D2D using the override button?

Hide Show

Dimming Mode (TE/LE) Selection

By default, all dimmer channels are set to Trailing Edge mode by default. The dimmer enables selecting the dimming mode per channel, Trailing edge (TE), or Leading edge (LE) compatible with the load changed via the front panel 

Note: 

  1. The dimmer channels do not automatically change mode when the connected load type is incompatible. If the selected mode is incompatible with the attached load, the channel may shut down and the indicator will slowly flash red, indicating a mode error.
  2. Before operating the load, ensure its compatibility with the dimming mode and check the correctness of its wiring.
 

To change the channel mode, press and hold the channel button for >10s. The channel will turn off briefly and turn on again in the opposite mode.

The button indicator will change color. I.e Green for Leading and Yellow for Trialing

 

1


 

How to enable the C-Bus Clock or PowerSupply on the new Digital Dimmer?

Hide Show
To enable or disable these features it's important to follow the instructions carefully for a consistant result, by doing the process too quickly or slowly may not change the state correctly.

For either option: Press and Hold toggle button 1 for greater than .5 seconds, quick press either button 3 or 4 * important that it's a quick press <0.5 sec, then release button 1 again after about 0.5-1 second, if you press and hold buttons 3 or 4 for too long or release button 1 and 3 or 1 and 4 at the same time the unit will not change state.

9 Switching of the inbuilt C-Bus power supply and C-Bus system clock if required
Ensure adequate C-Bus power supply is enabled in the bus by referring to the indication on the unit and the bus design by checking the right amount of power supplies enabled. In case of low C-Bus bus power indication, switch the inbuilt C-Bus Power supply in the dimmer.
Note: If the inbuilt switchable C-Bus power supply is enabled, the dimmer supplies power upto 200 mA to the network when connected to the mains.

How to enable/disable C-Bus power supply
The integrated C-Bus Power Supply can be enabled or disabled via the front panel by performing a short press on the top right channel button whilst holding down the top left channel button to toggle the enabled state, refer 9(a)

The enabled status of the integrated C-Bus Power Supply is shown on the Unit Indicator. Refer to diagnosis section (b).
The C-Bus Indicator state shows the state of the network voltage. If the C-Bus Indicator is flashing or off, the network voltage is too low, meaning there is insufficient C-Bus Power. additional power supplies may need to be enabled.

NOTE: It is important to ensure that no more than 2A of total C-Bus Power Supply capacity is enabled/connected to any one C-Bus network.

How to enable/disable the C-Bus system clock generator (if required)
The system clock is used to synchronize data communication over a C-Bus network. If a system clock is required, it can be enabled from the SpaceLogic C-Bus Commission software and the indicator buttons on the dimmer.

The integrated C-Bus Clock generator can be enabled or disabled via the front panel by performing a short press on the top second-to-right button whilst holding down the top left channel button to toggle the enabled state, refer 9(b)

C-Bus Toggle Buttons

Where to download the C-Bus Toolkit 1.17.4?

Hide Show
Where to download the C-Bus Toolkit 1.17.4?
Release Date: 02/04/2024
Version: V1.17.4
Reference: C-Bus_Toolkit_V1.17.4
C-Gate: 3.3.0 (build 1825)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10, Windows 8, Windows 7

What’s New 
C-Bus DALI-2 Gateway
Additional Measurement and Error Reporting application parameters are now supported in this release (future client feature).
C-Bus Digital Dimmers
The network burden property of the digital dimmer devices are now supported in the network calculator in this release.
Performance Improvement
Support has been added for the extended range of C-Bus replies for both new input and output devices in this release.

Fixes
• Fixed an issue with scanning and opening the older DALI Gateway (5502DAL) devices.
• Fixed an issue with setting the C-Bus power supply property for new output devices (future client feature).

Link to download C-Bus Toolkit 1.17.4
https://www.se.com/au/en/download/document/C-Bus-Toolkit_V1.17.4/
or
https://www.se.com/au/en/product-range/2216-spacelogic-cbus-home-automation-system/?parent-subcategory-id=88010&filter=business-5-residential-and-small-business#software-and-firmware
 

Where to download the SpaceLogic C-Bus Commission V2.2.0?

Hide Show
Where to download the SpaceLogic C-Bus Commission V2.2.0?
Release Date: 02/04/2024
Version: V2.2.0
Reference: C-Bus-Commission_V2.2.0
C-Gate: 3.3.0 (build 1825)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10.

What’s New 
• Dimmer conversion will add default channel name
When converting older LE dimmers DIMDN4 or DIMDN8 (L5504D2A or L5508D1A) to the new digital dimmers DIMDD4 (5504D2D) and DIMDD8 (5508D1D), the software will now automatically insert a default channel name per channel.

• Network Summary for a C-Bus Network
The C-Bus Network node will show the summary of network information and status including the C-Bus Current supplied and consumed values plus the network impedance value. This data is only taking the project devices into consideration (not the live network devices).

• View the in-built C-Bus power supply status of C-Bus Digital Dimmers on the live network
An icon has been added to the Status column in the Network Devices section of the C-Bus Devices workspace indicating whether the in-built C-Bus Power Supply for the new C-Bus Digital Dimmer (DIMDD4 and DIMDD8) is enabled or disabled.

Fixes
• Project conversion issues. The software will now show correctly when a project has truly failed to convert. Issue with projects in “Waiting” resolved.
• Multiple confirmation dialogues when delete a device in project.
• When transferring to a C-Bus Automation Controller and C-Bus Application Controller, updating a Tag Map name will create an Object if one does not exist, this can result in additional objects created in controller that were not defined in the Object List. Note, this release of SpaceLogic C-Bus Commission software is only compatible with the C-Bus Automation Controller and C-Bus Application Controller firmware version 1.16.0 (when using the Controller Sync function).
• Warn Before Off Enable Group in live network Digital Dimmer is blank and not auto created during a network scan.
• Network burden property of Digital Dimmers did not update the C-Bus summary data (not included in network calculator).

Known Issues
• A slight delay may be seen when switching views back and forth between the Measurement and Error applications where a large amount of data (150 items or more) exists.
• Clicking on the Main Menu repeatedly will result in a decrease in software performance. C-BUS COMMISSION RELEASE NOTES 2
• Switching projects 10 or more times will result in a decrease in software performance.
• Measurement application values presented from the live network may not appear truncated and rounded to reasonable decimal places.

Link to download the SpaceLogic C-Bus Commission V2.2.0
https://www.se.com/nz/en/download/document/C-Bus-Commission_V2.2.0/
or