Harmony Control Relays Modular 3 phase Voltage Control Relay 5A, 2CO, 120…277V AC

Home ProductsIndustrialHarmonyModular 3 phase Voltage Control Relay

Harmony Control Relays Modular 3 phase Voltage Control Relay 5A, 2CO, 120…277V AC

Item Number: RM35UB3N30

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Harmony Control Relays

Product or component type

3-phase control relay

Warranty

18 months

Physical

Connections - terminals

screw connectors

[in] rated current

5 A

Insulation resistance

  • > 500 MOhm at 500 V DC conforming to IEC 60255-5
  • > 500 MOhm at 500 V DC conforming to IEC 60664-1

Local signalling

  • LED (green) for power ON
  • LED (yellow) for relay ON

Connections - terminals

  • screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
  • screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
  • screw terminals, 1 x 0.2...2 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end

Mounting support

35 mm symmetrical DIN rail conforming to IEC 60715

Electrical durability

10000 cycles

Mechanical durability

30000000 cycles

Control type

without test button

Width

35 mm

Net weight

0.08 kg

Ambient air temperature for operation

-20...50 °C

Standards

IEC 60255-1

Product certifications

  • UL
  • C-Tick
  • GL
  • CSA
  • GOST

Ambient air temperature for storage

-40...70 °C

Relative humidity

95 % at 55 °C conforming to IEC 60068...2-30

Ip degree of protection

  • IP20 (terminals) conforming to IEC 60529
  • IP30 (casing) conforming to IEC 60529

Mercury free

Yes

Environmental disclosure

ENVPEP1601004EN

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Reach regulation

Reference contains Substances of Very High Concern above the threshold

China rohs regulation

X

California proposition 65

WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Others

Package 1 bare product quantity

1

Package 2 bare product quantity

48

Average percentage of recycled plastic content

0 %

Legacy weee scope

Out

Weee label

No

At least in Europe

Relay type

voltage control relay

Product specific application

for 3-phase supply

Relay name

RM35UB3

Relay monitored parameters

  • absence of neutral
  • overvoltage and undervoltage between phases
  • overvoltage and undervoltage between neutral

Time delay type

adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault

Switching capacity in va

1250 VA

Measurement range

120...277 V AC

Contacts type and composition

2 C/O

[uc] control circuit voltage

120...277 V

Reset time

1500 ms time delay

Maximum switching voltage

250 V AC/DC

Minimum switching current

10 mA at 5 V DC

Maximum switching current

5 A AC/DC

Supply voltage limits

114...329 V AC

Power consumption in va

0...3.9 VA AC

Control circuit frequency

50...60 Hz +/- 15 %

Voltage detection threshold

114 V

Output contacts

1 C/O + 1 C/O, 1 per threshold

Nominal output current

5 A

Hysteresis

2 %

Measurement accuracy

+/- 10 % of the full scale value

Run-up delay at power-up

650 ms

Maximum measuring cycle

150 ms measurement cycle as true rms value

Threshold adjustment voltage

2...20 % of Un selected

Repeat accuracy

  • +/- 0.5 % for input and measurement circuit
  • +/- 1 % for time delay

Measurement error

  • < 1 % over the whole range with voltage variation
  • 0.05 %/°C with temperature variation

Response time

< 200 ms (in the event of a fault)

Quality labels

CE

Operating position

any position without derating

Overvoltage category

III conforming to IEC 60664-1

[ui] rated insulation voltage

400 V conforming to IEC 60664-1

Tightening torque

0.6...1 N.m conforming to IEC 60947...1

Housing material

self-extinguishing plastic

Utilisation category

  • AC-12 conforming to IEC 60947-5-1
  • AC-13 conforming to IEC 60947-5-1
  • AC-14 conforming to IEC 60947-5-1
  • AC-15 conforming to IEC 60947-5-1
  • DC-12 conforming to IEC 60947-5-1
  • DC-13 conforming to IEC 60947-5-1
  • DC-14 conforming to IEC 60947-5-1

Operating rate

<= 360 operations/hour full load

[us] rated supply voltage

, self-powered

Safety reliability data

  • B10d = 470000
  • MTTFd = 502.2 years

Functionality

overvoltage and undervoltage detection

Compatibility code

RM3

Electromagnetic compatibility

  • emission standard for industrial environments conforming to IEC 61000-6-4
  • emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
  • immunity for industrial environments conforming to NF EN/IEC 61000-6-2

Vibration resistance

  • 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6
  • 1 gn (f= 57.6-150 Hz) conforming to IEC 60255-21-1

Shock resistance

5 gn conforming to IEC 60068-2-27

Pollution degree

3 conforming to IEC 60664-1

Directives

  • 73/23/EEC - low voltage directive
  • 89/336/EEC - electromagnetic compatibility

Dielectric test voltage

2 kV, 1 min AC 50 Hz

Non-dissipating shock wave

4 kV

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

4.700 cm

Package 1 width

7.800 cm

Package 1 length

9.700 cm

Package 1 weight

123.000 g

Unit type of package 2

S03

Number of units in package 2

48

Package 2 height

30.000 cm

Package 2 width

30.000 cm

Package 2 length

40.000 cm

Package 2 weight

6.690 kg

Green premium status for reporting

Green Premium product

Total lifecycle carbon footprint

36 kg CO2 eq.

Carbon footprint of the manufacturing phase [a1 to a3]

1.6443636364

Carbon footprint of the manufacturing phase [a1 to a3]

2 kg CO2 eq.

Carbon footprint of the distribution phase [a4]

0.0103214545

Carbon footprint of the distribution phase [a4]

0 kg CO2 eq.

Carbon footprint of the installation phase [a5]

0.0003991345

Carbon footprint of the installation phase [a5]

0 kg CO2 eq.

Carbon footprint of the use phase [b2, b3, b4, b6]

34.3354666667

Carbon footprint of the use phase [b2, b3, b4, b6]

34 kg CO2 eq.

Sustainable packaging

Yes

Carbon footprint of the end-of-life phase [c1 to c4]

0.0464858182

Carbon footprint of the end-of-life phase [c1 to c4]

0 kg CO2 eq.

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Total lifecycle carbon footprint

36.0370367103

Average percentage of recycled metal content

0 %

Packaging made with recycled cardboard

Yes

Packaging without single use plastic

Yes

End of life manual availability

ENVEOLI1601004EN

Take-back

No

Warranty (in months)

18
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Technical illustration

  • Application Notes

  • Certificates (MSDS)

  • eTechPub

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)