Soft start-soft stoft unit ATS U01N2

Soft-Start Stop 12A 380 415V

Catalogue Number: ATS01N212QN
Soft start-soft stoft unit ATS U01N2
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
Altistart 01
Product or component type
soft starter
Product destination
asynchronous motors
Product specific application
simple machine
Device short name
ATS01
Network number of phases
3 phases
[Us] rated supply voltage
380...415 V - 10...10 %
Motor power kW
5.5 kW, 3 phases at 380...415 V
IcL starter rating
12 A
Utilisation category
AC-53B conforming to EN/IEC 60947-4-2
Current consumption
60 A at nominal load
Type of start
start with voltage ramp
Power dissipation in W
  • 4 W at full load and at end of starting
  • 124 W in transient state
    • Assembly style
      with heat sink
      Function available
      integrated bypass
      Supply voltage limits
      342-456 V
      Supply frequency
      50...60 Hz - 5...5 %
      Network frequency
      47.5...63 Hz
      Output voltage
      <= power supply voltage
      [Uc] control circuit voltage
      built into the starter
      Starting time
      adjustable from 1 to 10 s
      Deceleration time symb
      adjustable from 1 to 10 s
      Starting torque
      30...80 % of starting torque of motor connected directly on the line supply
      Discrete input type
      logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm
      Discrete input voltage
      24...40 V
      Discrete input logic
      positive LI1, LI2, BOOST at State 0: < 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA
      Discrete output current
    • 2 A DC-13
    • 3 A AC-15
      • Discrete output type
      • open collector logic LO1 end of starting signal
      • relay outputs R1A, R1C NO
        • Discrete output voltage
          24 V (voltage limits: 6...30 V) open collector logic
          Minimum switching current
          10 mA at 6 V DC for relay outputs
          Maximum switching current
        • relay outputs: 2 A at 250 V AC cos phi = 0.5 and L/R = 20 ms inductive load
        • relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive load
          • Display type
          • 1 LED (green) for starter powered up
          • 1 LED (yellow) for nominal voltage reached
            • Tightening torque
            • 1.9-2.5 N.m
            • 0.5-0.5 N.m
              • Electrical connection
              • 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit
              • screw connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit
              • screw connector - rigid 1 0.5...2.5 mm² AWG 14 control circuit
              • 4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit
              • screw connector - rigid 2 0.5...1 mm² AWG 17 control circuit
              • screw connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit
              • 4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuit
              • screw connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit
              • 4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit
              • 4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuit
                • Marking
                  CE
                  Operating position
                  vertical +/- 10 degree
                  Height
                  124 mm
                  Width
                  45 mm
                  Depth
                  131 mm
                  Net weight
                  0.42 kg
                  Compatibility code
                  ATS01N2
                  Power range
                  4-6 kW at 380-440 V 3 phases
                  Motor starter type
                  soft starter
                  Electromagnetic compatibility
                • conducted and radiated emissions level B conforming to CISPR 11
                • immunity to electrical transients level 4 conforming to IEC 61000-4-4
                • immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
                • micro-cuts and voltage fluctuation conforming to IEC 61000-4-11
                • voltage/current impulse level 3 conforming to IEC 61000-4-5
                • conducted and radiated emissions level B conforming to IEC 60947-4-2
                • damped oscillating waves level 3 conforming to IEC 61000-4-12
                • electrostatic discharge level 3 conforming to IEC 61000-4-2
                • EMC immunity conforming to EN 50082-1
                • EMC immunity conforming to EN 50082-2
                • harmonics conforming to IEC 1000-3-2
                • harmonics conforming to IEC 1000-3-4
                • immunity to conducted interference caused by radio-electrical fields level 3 conforming to IEC 61000-4-6
                  • Standards
                    EN/IEC 60947-4-2
                    Product certifications
                  • B44.1-96/ASME A17.5 for starter wired to the motor delta terminal
                  • CCC
                  • UL
                  • GOST
                  • CSA
                  • C-Tick
                    • IP degree of protection
                      IP20
                      Pollution degree
                      2 conforming to EN/IEC 60947-4-2
                      Vibration resistance
                    • 1 gn (f= 13-150 Hz) conforming to EN/IEC 60068-2-6
                    • 1.5 mm peak to peak (f= 3-13 Hz) conforming to EN/IEC 60068-2-6
                      • Shock resistance
                        15 gn for 11 ms conforming to EN/IEC 60068-2-27
                        Relative humidity
                        5-95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
                        Ambient air temperature for operation
                      • -10-40 °C (without)
                      • 40-50 °C (with current derating of 2 % per °C)
                        • Ambient air temperature for storage
                          -25-70 °C conforming to EN/IEC 60947-4-2
                          Operating altitude
                        • <= 1000 m without
                        • > 1000 m with current derating of 2.2 % per additional 100 m
                          • REACh Regulation
                            Free of Substances of Very High Concern above the threshold
                            REACh free of SVHC
                            Yes
                            EU RoHS Directive
                            Pro-active compliance (Product out of EU RoHS legal scope)
                            Toxic heavy metal free
                            Yes
                            Mercury free
                            Yes
                            RoHS exemption information
                            Yes
                            China RoHS Regulation
                            X
                            WEEE
                            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                            California proposition 65
                            WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
                            Warranty
                            18 months

                            Documents & downloads

                            hide show
                            Filter items
                            • All

                            • CAD Files and Packs

                            • Product Brochures

                            • Technical Data Catalogues

                            • End of Life Manual

                            • Installation Instruction

                            • Certificates (MSDS)

                            • eTechPub

                            Frequently Asked Questions

                            hide show

                            Does the ATS01 come with a shorting contactor?

                            Issue:
                            Does the ATS01 come with a shorting contactor?

                            Product Line:
                            Altistat 01

                            Environment:
                            All

                            Cause:
                            N/A

                            Resolution:
                            All of the ALTISTART 01 models, except the ATS01N103FT and ATS01N106FT, have an internal shorting contactor as standard.

                            Is the LH4N still available?

                            Issue:
                            Is the LH4N still available?

                            Product Line:
                            LH4N

                            Environment:
                            All models and all serial numbers

                            Cause:
                            Customer was looking for purchasing the LH4N112RT7.

                            Resolution:
                            No, the LH4N soft starter is obsolete. Please replace with the appropriate ATS01 or ATS22 soft starter. Consider application needs and features of currently-offered products.


                             

                            Are Softstarters acceptable for use in a Fire Pump applications?

                            Issue:
                            Are Softstarters acceptable for use in a Fire Pump applications?

                            Product line:
                            Altistart 22 48 ATS22 ATS48

                            Environment:
                            all

                            Cause:
                            Fire pump systems typically require the motors to run until they fail, without faulting the controller

                            Resolution:
                            No. The softstarters are not rated for Fire pump requirements and does not meet the requirements.
                             

                            How can ATS01N2...LU, QN, RT be started without control wires?

                            Issue:
                            How can ATS01N2...LU, QN, RT be started without control wires?

                            Product Line:
                            Altistart 01 Soft Starters with "LU", "QN", or "RT" at the end of the part number

                            Environment:
                            All

                            Cause:
                            Need to start the Soft Starter with power up

                            Resolution:
                            Add a jumper between terminals LI+ and LI2.  This provides a continuous RUN command.  When power is supplied to the ATS01, it will immediately begin to start the motor.  Removing power will result in a freewheel stop.

                             

                            What are the adjustment ranges for the dials on an ATS01N2..LU/QN/RT?

                            What are the adjustment ranges for the dials on an ATS01N2..LU/QN/RT?


                            Issue:

                            Adjusting Altistart 01 Soft Starters


                            Product Line:
                            Altistart 01


                            Environment:
                            All


                            Cause:
                            N/A


                            Resolution:

                            For both the START TIME and STOP TIME dials, setpoint A is 1second and setpoint E is 10seconds.  There is a linear relationship from A to E setpoints.
                            For the INITIAL VOLTAGE dial, setpoint A is 30% and setpoint E is 80% of full voltage.  There is a linear relationship from A to E setpoints.
                             

                            What is the replacement for the High HP ATS01N softstarters?

                            Issue:
                            Wants to order the ATS01N230LY, ATS01N244LY, ATS01N272LY or ATS01N285LY

                            Product line:
                            ATS01, Altistart 01, High HP

                            Environment:
                            All models

                            Cause:
                            The launch of the ATS22 in 2011 caused the High HP units to become redundant.

                            Resolution:

                            The ATS01 High HP units were replaced with the ATS22 units.  These are functional replacements only.  The ATS01 had no overload protection, an internal power supply and simple dial adjustments.  The ATS22 will require external 120V or 230V power.  There are no dials to adjust, but the unit will need to be programmed.  See the ATS22 User Maual, document BBV51300 to review the wiring, dimensions and programming.

                            ATS01N230LY - 32A rated.  Replaced by ATS22D32S6U
                            ATS01N244LY - 44A rated.  Replaced by ATS22D47S6U
                            ATS01N272LY - 72A rated.  Replaced by ATS22D75S6U
                            ATS01N285LY - 85A rated.  Replaced by ATS22D88S6U

                             

                            What are the adjustment ranges for the dials on an ATSU01N2..LT?

                            For both the START TIME and STOP TIME dials, setpoint A is 1second and setpoint E is 10seconds.  There is a linear relationship from A to E setpoints.
                            For the INITIAL VOLTAGE dial, setpoint A is 30% and setpoint E is 80% of full voltage.  There is a linear relationship from A to E setpoints.



                            CTA-ID : 2061385

                            Does Schneider offer a soft start for a single phase motor?

                            Issue:
                            Soft start for a single phase motor?

                            Product Line:
                            ATS01

                            Environment:
                            All

                            Cause:
                            Needs a soft starter for a single phase motor. 

                            Resolution:
                            Yes, but the offering is limited.  The ATS01N1**FT products are rated for single phase motors up to 2HP at 240V and 1/2HP at 120V.
                            See the attachment beginning on page 34.  Reference page 40 for part number selection.

                            How many SCRs are built in the ATS01N232LU?

                             Issue:
                            How many SCRs are built in the ATS01N232LU? 

                            Product Line:
                            Altisart 01

                            Environment:
                            All serial number for Altistart 01 Soft Starters.

                            Cause:
                            N/A

                            Resolution:
                            There are two SCRs built in the ATS01N232LU Soft Starters.

                            What are the dimensions for the ATS01N230LY and ATS01N244LY?

                            Issue:
                            What are the dimensions for the ATS01N230LY and ATS01N244LY?

                            Product Line:
                            Altistart 01

                            Environment:
                            All

                            Cause:
                            N/A

                            Resolution:
                            Both units have the same dimensions:
                            4.96 (126 mm) inches deep
                            5.75 (146 mm) inches tall
                            7.09 (180 mm) inches wide

                            What are the adjustment ranges for the dials on an ATS01N1..FT?

                            For the START TIME dial, setpoint A is 1second and setpoint E is 5seconds.  There is a linear relationship from A to E setpoints.
                            For the INITIAL VOLTAGE dial, setpoint A is 30% and setpoint E is 80% of full voltage.  There is a linear relationship from A to E setpoints.



                            CTA-ID : 2061387

                            ATS01N222RT Can you do a soft stop?

                            Issue: 
                            How do I get the ATS01 to softstop? 
                             
                            Product Line:
                            ATS01 Altistart 01 Altivar

                            Environment:
                            ATS01.....RT

                            Cause:
                            Need soft stopping. 

                            Resolve: 
                            If you have a jumper between LI2 and LI+ terminals, you will have soft starting with line power and a coast to stop when line power is removed.

                            If you have a start-stop signal that closes LI2 to LI+ to start, it will softstart according to the start dial.  When you open this contact it will soft stop (decelerate) according to the stop dial setting.
                            Show More