| Life cycle assessment data |
Yes |
| Substance regulation data deliverable |
Yes |
| Legacy weee scope |
In |
| Average percentage of recycled plastic content |
0 % |
| Package 3 bare product quantity |
320 |
| Package 2 bare product quantity |
20 |
| Package 1 bare product quantity |
1 |
| Weee label |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| |
At least in Europe |
| Warranty duration(in months) bmecat |
18 |
| Device short name |
LC1D |
| Contactor application |
- resistive load
- motor control
|
| Utilisation category |
|
| Poles description |
3P |
| [uc] control circuit voltage |
110 V AC 50/60 Hz |
| Motor power kw |
- 3 kW at 220...230 V AC 50/60 Hz (AC-3)
- 5.5 kW at 380...400 V AC 50/60 Hz (AC-3)
- 5.5 kW at 415...440 V AC 50/60 Hz (AC-3)
- 7.5 kW at 500 V AC 50/60 Hz (AC-3)
- 7.5 kW at 660...690 V AC 50/60 Hz (AC-3)
- 3.7 kW at 400 V AC 50/60 Hz (AC-4)
- 3 kW at 220...230 V AC 50/60 Hz (AC-3e)
- 5.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
- 5.5 kW at 415...440 V AC 50/60 Hz (AC-3e)
- 7.5 kW at 500 V AC 50/60 Hz (AC-3e)
- 7.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
|
| Motor power hp |
- 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
- 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors
- 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors
- 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors
- 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
- 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors
|
| Compatibility code |
LC1D |
| Pole contact composition |
3 NO |
| Protective cover |
with |
| [ith] conventional free air thermal current |
- 25 A (at 60 °C) for power circuit
- 10 A (at 60 °C) for signalling circuit
|
| Irms rated making capacity |
- 250 A at 440 V for power circuit conforming to IEC 60947
- 140 A AC for signalling circuit conforming to IEC 60947-5-1
- 250 A DC for signalling circuit conforming to IEC 60947-5-1
|
| Rated breaking capacity |
250 A at 440 V for power circuit conforming to IEC 60947 |
| [icw] rated short-time withstand current |
- 105 A 40 °C - 10 s for power circuit
- 210 A 40 °C - 1 s for power circuit
- 30 A 40 °C - 10 min for power circuit
- 61 A 40 °C - 1 min for power circuit
- 100 A - 1 s for signalling circuit
- 120 A - 500 ms for signalling circuit
- 140 A - 100 ms for signalling circuit
|
| Associated fuse rating |
- 10 A gG for signalling circuit conforming to IEC 60947-5-1
- 40 A gG at <= 690 V coordination type 1 for power circuit
- 25 A gG at <= 690 V coordination type 2 for power circuit
|
| Average impedance |
2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Power dissipation per pole |
- 0.36 W AC-3
- 1.56 W AC-1
- 0.36 W AC-3e
|
| [ui] rated insulation voltage |
- power circuit: 690 V conforming to IEC 60947-4-1
- power circuit: 600 V CSA certified
- power circuit: 600 V UL certified
- signalling circuit: 690 V conforming to IEC 60947-1
- signalling circuit: 600 V CSA certified
- signalling circuit: 600 V UL certified
|
| Overvoltage category |
III |
| Pollution degree |
3 |
| [uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947 |
| Safety reliability level |
- B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
- B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
|
| Control circuit type |
AC at 50/60 Hz standard |
| Coil technology |
without built-in suppressor module |
| Control circuit voltage limits |
- 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
- 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz
- 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
- 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
|
| Inrush power in va |
- 70 VA 60 Hz cos phi 0.75 (at 20 °C)
- 70 VA 50 Hz cos phi 0.75 (at 20 °C)
|
| Hold-in power consumption in va |
- 7.5...7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
- 7 VA 50 Hz cos phi 0.3 (at 20 °C)
|
| Heat dissipation |
2...3 W at 50/60 Hz |
| Operating time |
- 12...22 ms closing
- 4...19 ms opening
|
| Maximum operating rate |
3600 cyc/h at 60 °C |
| Tightening torque |
- power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
- power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
- power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
|
| Auxiliary contact composition |
1 NO + 1 NC |
| Auxiliary contacts type |
- type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
- type mirror contact 1 NC conforming to IEC 60947-4-1
|
| Signalling circuit frequency |
25...400 Hz |
| Minimum switching voltage |
17 V for signalling circuit |
| Minimum switching current |
5 mA for signalling circuit |
| Non-overlap time |
- 1.5 ms on de-energisation between NC and NO contact
- 1.5 ms on energisation between NC and NO contact
|
| Contact compatibility |
M2 |
| [uc] control circuit voltage |
110 V |
| Maximum motor phase current |
12 A |
| Protective treatment |
TH conforming to IEC 60068-2-30 |
| Permissible ambient air temperature around the device |
- -40...60 °C
- 60...70 °C with derating
|
| Operating altitude |
0...3000 m |
| Fire resistance |
850 °C conforming to IEC 60695-2-1 |
| Flame retardance |
V1 conforming to UL 94 |
| Mechanical robustness |
- vibrations contactor open (2 Gn, 5...300 Hz)
- vibrations contactor closed (4 Gn, 5...300 Hz)
- shocks contactor open (10 Gn for 11 ms)
- shocks contactor closed (15 Gn for 11 ms)
|
| Unit type of package 1 |
PCE |
| Number of units in package 1 |
1 |
| Package 1 height |
5.000 cm |
| Package 1 width |
9.200 cm |
| Package 1 length |
11.200 cm |
| Package 1 weight |
354.000 g |
| Unit type of package 2 |
S02 |
| Number of units in package 2 |
20 |
| Package 2 height |
15.000 cm |
| Package 2 width |
30.000 cm |
| Package 2 length |
40.000 cm |
| Package 2 weight |
7.375 kg |
| Unit type of package 3 |
P06 |
| Number of units in package 3 |
320 |
| Package 3 height |
75.000 cm |
| Package 3 width |
60.000 cm |
| Package 3 length |
80.000 cm |
| Package 3 weight |
129.380 kg |
| Green premium status for reporting |
Green Premium product |
| Total lifecycle carbon footprint |
23 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] |
1.3477959823131842 |
| Carbon footprint of the manufacturing phase [a1 to a3] |
1 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] |
0.15063591165520598 |
| Carbon footprint of the distribution phase [a4] |
0.2 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] |
0.05308452752054227 |
| Carbon footprint of the installation phase [a5] |
0.1 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] |
21.825019899655352 |
| Carbon footprint of the use phase [b2, b3, b4, b6] |
22 kg CO2 eq. |
| Sustainable packaging |
Yes |
| Pvc free |
Yes |
| F-gas free |
N/A |
| Take-back |
No |
| Product contributes to saved and avoided emissions |
No |
| Removable battery |
N/A |
| Total lifecycle carbon footprint |
23.376536321144286 |
| Average percentage of recycled metal content |
0 % |
| Packaging made with recycled cardboard |
Yes |
| Packaging without single use plastic |
Yes |
| China rohs label |
1 |
| Pvc free |
Yes |
| End of life manual availability |
ENVEOLI1501004 |
| Take-back |
No |
| Weee label |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) |
18 |