C-Bus Control and Management System PC Interface Housed in A 4M, Din Rail Enclosure

C-Bus Control and Management System PC Interface Housed in A 4M, Din Rail Enclosure

Item Number: 5500PC

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

C-Bus

Range

C-Bus

Product brand

Clipsal

Product or component type

interface module

Device application

connection

Physical

Mounting support

DIN rail

Local signalling

LED

Ip degree of protection

IP20

Reach free of svhc

Yes

Toxic heavy metal free

Yes

Mercury free

Yes

Rohs exemption information

Yes

Environmental disclosure

ENVPEP111268EN

Eu rohs directive

Compliant

Reach regulation

Free of Substances of Very High Concern above the threshold

China rohs regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Others

Package 1 bare product quantity

1

Average percentage of recycled plastic content

0 %

Legacy weee scope

In

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Weee applicability

Finished product

At least in Europe

Number of modules

4

Communication port support

RS232

Transmission rate

9600 bauds

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

9.0 cm

Package 1 width

12.5 cm

Package 1 length

16.0 cm

Package 1 weight

351.0 g

Total lifecycle carbon footprint

0 kg CO2 eq.

Carbon footprint of the manufacturing phase [a1 to a3]

0

Carbon footprint of the manufacturing phase [a1 to a3]

0 kg CO2 eq.

Carbon footprint of the distribution phase [a4]

0

Carbon footprint of the distribution phase [a4]

0 kg CO2 eq.

Carbon footprint of the installation phase [a5]

0

Carbon footprint of the installation phase [a5]

0 kg CO2 eq.

Carbon footprint of the use phase [b2, b3, b4, b6]

0

Carbon footprint of the use phase [b2, b3, b4, b6]

0 kg CO2 eq.

Sustainable packaging

No

Carbon footprint of the end-of-life phase [c1 to c4]

0

Carbon footprint of the end-of-life phase [c1 to c4]

0 kg CO2 eq.

Pvc free

No

Halogen-free status

Halogen free product

Silicone-free 

No

Energy efficiency optimized

False

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Total lifecycle carbon footprint

0

Average percentage of recycled metal content

0 %

Packaging made with recycled cardboard

Yes

Packaging without single use plastic

No

Halogen-free status

Halogen free product

Pvc free

No

Silicone-free

No

End of life manual availability

ENVEOLI111254EN

Take-back

No

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Warranty (in months)

18
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Operating Manuals

  • Specification Guide

  • Application Notes

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

  • Software - Release

  • Software - Data Library

Important: Some software files may need a mySchneider or Club login to download.

Frequently Asked Questions

Where do I download C-Bus software from? looking for the place to find this software within the portal, not just a URL.

Hide Show
 

Please see below how to get to our Software and firmware

https://ecoxpert.se.com/

1. Home
2. All products
3. Residential and Small Business
4. Home Automation
5. C-Bus Home Automation
6. SpaceLogic C-Bus Home Automation System
  1
2
 

Where can I find C-Bus Protocol documents?

Hide Show

Where can I find C-Bus Protocol documents?

Answer:
C-Bus Protocol documents is attached

C-Bus Quick Start Guide Serial Protocols.pdf
 

How to set up the second machine to control the same project?

Hide Show

How to set up the second machine to control the same project?

follow the instruction in toolkit help file ''Setting up a new remote projects connection"

1

Setting up a new remote projects connection

You can connect to C-Bus projects remotely by setting up connectivity between C-Bus Toolkit software and C-Gate server, and C-Bus Toolkit project folders.

Before you start

§

The C-Bus Toolkit host computer needs to be able to set up an ethernet connection between the C-Gate server and the C-Bus Toolkit host computer

 

§

Access to the C-Gate server to update a configuration file for the purpose of identifying each C-Bus Toolkit host computer.

Follow the procedures below to successfully connect remotely to C-Gate project folders.

Obtaining permissions on the ethernet

If you are intending to connect to a C-Bus Toolkit projects which reside on host computers on an ethernet, you must ensure that your computer has permission to access the network. In most cases, the building site computers have firewall protection. To get access, you need to contact the system administrators who grant login and password access.

Identifying the C-Bus Toolkit host computer

The C-Gate server must know of the existence of any C-Bus Toolkit software which wants to gain access to C-Bus project folders. To be a trusted user of the C-Gate server, the hostname or IP address of the C-Bus Toolkit host computer must be added to a configuration file on the C-Gate server.

Finding the IP address of C-Bus Toolkit

To find the IP address from a Microsoft Windows operation system, follow the procedure below:

1.

Click the Start menu on your host computer

 

2.

Click the Run... option. The Run dialog box appears.

 

3.

Type cmd in the Open: field of the Run dialog box. The cmd.exe window opens.

 

4.

At the command line prompt, type: ipconfig. The window displays the ethernet local area connection.

 

5.

Look for the IP address in the window. An example of an IP address would be: 10.178.143.159.

To close the Microsoft Windows command line window, type: exit.

Adding the C-Bus Toolkit IP Address to the C-Gate server

To add the C-Bus Toolkit host computer to the access.txt file, follow the procedure below:

1.

For windows operating systems, the configuration file is named: access.txt and is located at the host computer location of: C:\Clipsal\C-Gate 2\config. Use Microsoft Windows search facility to find the access.txt configuration file.

 

2.

Double-click on the access.txt file to open a Microsoft Notepad editing session. This opens the access.txt file in Microsoft Notepad as shown in the sample content below (Note that the exact contents of this file may vary):

##C-Gate Server Access Control File

## This file was written automatically by a command issued to the server

## Created:Tue Oct 05 16:22:26 CST 2004

## File name: C:\clipsal\c-gate\config\access.txt

interface 0:0:0:0:0:0:0:1 Program

interface 127.0.0.1 Program

interface localhost Program

## End of access control file

3.

Below the interface localhost Program line, add the following:

remote [IP Address of C-Bus Toolkit host computer] Program

4.

Repeat this for each host C-Bus Toolkit host computer, you want to connect to the C-Gate projects folder.

 

5.

Save the file by clicking File menu > Save option in Microsoft Notepad.

Adding the C-Gate server IP address in C-Bus Toolkit

You need to identify the C-Gate server by its IP address in order to set up C-Bus Toolkit so that it can open the C-Bus Toolkit project folders residing with the C-Gate server. To carry this out, follow the procedure below:

1.

Click on Connect to a Remote C-Gate option in the File menu of C-Bus Toolkit. The C-Gate Site dialog box appears.

 

2.

In the Site Name field, type a descriptive name for the C-Gate server project folders. The name must be a single word with no spaces and contain alpha-numeric characters. Characters outside of the following sets: a-z, A-Z, 1-9, are not valid.

 

3.

In the Host Name field, type the host computer name of the C-Gate server. If you do not know that precise host name, leave the field blank.

 

4.

In the IP Address field, add the IP address - numbers only.

 

5.

Click the OK button to save the remote IP location.

C-Bus Toolkit searches for the remote IP location. If the search is successful, the remote C-Gate project folders appear in the C-Bus Toolkit treeview. If the search result is unsuccessful, C-Bus Toolkit sends an error message.


 

Which version of Schedule Plus is compatible with C-Gate 3?

Hide Show

Schedule plus V5.4.0 is compatible with C-Gate 3

Release note:

1

Download link:

https://www.se.com/au/en/product-range/2216-spacelogic-cbus-home-automation-system/#software-and-firmware

2

3


 

Can C-Bus C-Gate 3 Toolkit export projects in xml format?

Hide Show
Can C-Bus C-Gate 3 Toolkit export projects in xml format?

No, it can not, but SpaceLogic C-Bus Commission (SLCC) can do.
 

Which version of SpaceLogic C-Bus Commission (SLCC) can export projects in xml format?

Hide Show
Which version of SpaceLogic C-Bus Commission (SLCC) can export projects in xml format?
SLCC V2.6.0 or later
 

Where to download the C-Bus Toolkit 1.16.3?

Hide Show
Where to download the C-Bus Toolkit 1.16.3?
Release Date: 29/06/2023
Version: V1.16.3
Reference: C-Bus_Toolkit_V1.16.3
C-Gate: 2.11.10
Operating Systems:  Windows 10, Windows 7, Windows 8, Windows Vista, Windows x86 / x64

It contains eDLT firmware version: V1.7.0

https://www.se.com/au/en/download/document/C-Bus_Toolkit_V1.16.3/
 

How to install PUSH Module for CBus 3.8.2

Hide Show
For more information on how to install and configure the PUSH Controls Module: CBus 3.8.2

Please see the attached PDF user guide
Also attached is the PEMOD Module file that will be required for the installation via PUSH Project Editor.

Product Logo
 

How to install PUSH Module for WiserLink 1.1

Hide Show
For more information on how to install and configure the PUSH Controls Module: WiserLink 1.1

Please see the attached PDF user guide
Also attached is the PEMOD Module file that will be required for the installation via PUSH Project Editor.

Product Logo