Standard Series Flush Plate Architrave Size, Switch Plate 1 Gang (75 x 32mm) | White Electric
Item Number: 31-WE
Specifications
Design
Range of product
Product brand
Product destination
Physical
Fixing mode
Marking
Mounting position
Fixing center
Width
Height
Depth
Number of gangs
Eu rohs directive
Mercury free
Rohs exemption information
China rohs regulation
Environmental disclosure
Circularity profile
Material
Material
Others
Package 1 bare product quantity
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Packaging made with recycled cardboard
Packaging without single use plastic
Take-back
Take-back
Product contributes to saved and avoided emissions
Removable battery
Minimum percentage of recycled plastic content
Documents & downloads
hide show-
All
-
Technical Data Catalogues
Frequently Asked Questions
How to trigger a action selector from C-Bus key switch
Hide ShowHow to trigger a action selector from C-Bus key switch
- SELECT TRIGGER CONTROL FROM SECONDARY APPLICATION (UNIT IDENTIFICATION TAP)
- SELECT THE SECONDARY APPLICATION FROM (P) TO (S) FROM THE SELECT KEY
- SELECT THE TRIGGER CONTROL GROUP AND THEN FUNCTION AS TRIGGER 1 OR 2
- SELECT THE THREE DASH TO SELECT THE ACTION SELECTOR
eg.5085DL
eg.5031nmml
I am installing a 2-wire Dimmer, when should I be using a 31CAP or 31LCDA?
Hide ShowThe 31CAP and 31LCDA both have separate uses to resolve issues experienced with 2-wire Dimmers.
The 31CAP should be used when minimum load of the device is not being met, this is usually indicated by the load/light, that is controlled by the dimmer, by glowing when it should be off. Adding the 31CAP will increase the load and prevent the load/light from glowing in the off state. Depending on how far off minimum load you are more than one 31CAP may be required.
The 31LCDA should be used in instances where the load/light is flickering constantly, which indicates an issue with compatibility with the 2-wire dimmer used. The 31LCDA resolves these incompatibilities and flickering should then stop, if the flickering is reduced but still present you may need another 31LCDA to completely resolve. No more than 3x 31LCDA’s should be used on one dimmer.
Why does my 41E300PBUD2SM (Dimmer) leave my light glowing when the dimmer is off?
Hide ShowYou can then connect a 31CAP to increase the loading.
What is the breakdown of components for 9001KYK117?
Hide ShowBreakdown of components for 9001KYK117
Product Line:
Harmony Push Buttons
Environment:
Harmony Control Stations
Cause:
Product Features
Resolution:
9001KYK117 components are:
1-9001KY1S1 (red enclosure)
1-9001K15 (break glass operator)
1-9001KA1 (1 open and 1 closed contact)
1-9001KN799RP (legend plate)
Replacement glass discs are 9001K57 (package of five)
How do you distribute MAXBAR from the main row to other rows, keeping the system more professional?
Hide ShowWhat is MAXBAR?
Hide ShowThere are Comb busbar for 1P+N and 3P+N applications. There is one variant with neutral terminal block for rows with Main Switch and another variant for rows without Main switch.
How can MAXBAR help me to save time during switchboard installation ?
Hide ShowWhat colours are the new Iconic Outdoor Products available in?
Hide ShowDo I need to use any caps or silicone on the mounting screws on the Iconic Outdoor?
Hide ShowWhat size conduit entries can be used with Iconic Outdoor?
Hide ShowWhat is the difference between the 31Cap and 31LCDA?
Hide Show31CAP - Increases minimum load.
For further information please visit http://www.clipsal.com/Trade/Products/ProductDetail?catno=31CAP
31LCDA - Assists with compatibility issues.
For further information please visit http://www.clipsal.com/Trade/Products/ProductDetail?catno=31LCDA
How is an Altivar VFD set to always run a particular speed when no reference input is connected?
Hide ShowWants the Altivar VFD set to always run at a particular speed when no reference input is connected.
Product Line:
Altivar 12, 32, 312, 61, 71, 212, 320
Environment:
All models
Cause:
VFD does not run the motor without a speed reference.
Resolution:
If there is no external speed reference when the VFD gets a run command, then it will always run at the minimum speed programmed to the VFD. Set the minimum speed parameter to the desired run speed. Use parameter LSP for the Altivar12, 32, 312, 320, 61, 71 drives. Use parameter LL for the Altivar 212 drive. These can be adjusted while the motor is running.
What is a possible cause of OSF fault on the ATV31 or ATV312 drive?
Hide ShowWhat is a possible cause of OSF fault?
Product Line:
Altivar 312 , ATV312
Environment:
All
Cause:
Line voltage is too high
Problem with the line supply
Voltage spike on line side affecting DC bus voltage
Switching power factor correction capacitors by the facility or by the utility company
Resolution:
If this causes the DC bus voltage to go too high, the drive will trip on ObF. One possible cause for ObF to occur is a decel time that the drive is not able to meet because of excessive inertia from the motor load. See FAQ on ObF for resolutions.
- Check the line voltage at L1, L2, L3 on the drive terminals
- Compare the line voltage reading with the ULn display ( SUP menu)
- Measure the DC Bus voltage
- Monitor line power for voltage spikes