Standard Series, Automatic Single Socket Outlet, 250VAC, 10A, Skirting Duct White Electric
Item Number: 12M-WE
Datasheet
Specifications
Design
Range of product
Product or component type
Product brand
Physical
Quantity per set
Marking
Local signalling
Mounting support
Fixing mode
[in] rated current
[ue] rated operational voltage
Depth
Length
Width
Number of poles
Standards
Eu rohs directive
China rohs regulation
Environmental disclosure
Circularity profile
Others
Package 1 bare product quantity
Cover type
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Documents & downloads
hide show-
All
-
Product Brochures
-
Technical Data Catalogues
-
Environmental Disclosure
-
Specification Guide
Frequently Asked Questions
hide showLC1D09 - LC1D38 Coil tolerance
Product Line:
Contactors and Starters, IEC
Environment:
Tesys D Contactors
Cause:
Needs the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38.
Resolution:
AC single frequency coils: 50Hz and 60 Hz (-20% / +10%);
AC dual frequency coils: 50Hz (-20% / +10%) ; 60Hz (-15% / +10%)
DC standard coil for LC1D09 -D38 and LC1DT20 to DT40: (-30% / +25%)
DC standard coil for LP1D12 and D25: (-20% / +10%)
DC wide range coil for LP1D12 and D25 : (-30% to +25%)
Identifying maximum voltage of an LC1D contactor
Product Line:
TeSys D Contactors
Environment:
Contactors and Starters IEC
Resolution:
IThe maximum voltage per UL and CSA is 600VAC.
What is the altitude derating for a TeSys D-Line contactor?
Product Line:
Digest 177 Section 18 : Contactors and Starters, IEC
Environment:
North American Products
Resolution:
The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:
Voltage
3500m x 0.90
4000m x 0.80
4500m x 0.70
5000m x 0.60
Current
3500m x 0.92
4000m x 0.90
4500m x 0.88
5000m x 0.86
For example, an LC1D80 at 5000 meters:
- The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
- The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.
Are the Powerpact and Legacy rated for feed in either direction?
Product Line:
Molded Case Switches
Resolution:
Yes, the molded case switches have been UL tested for reverse feed applications and are not marked line and load.
Change the carrier switching frequency in an ATV66 drive
Product Line:
Altivar ATV66
Environment:
All
Cause:
Needs to change the switching frequency because of motor noise.
Resolution:
The only way to change carrier frequency is to go from CT or VT to VTLN or NOLD in menu 7.13.
There is no separate parameter available for switching frequency adjustment.
Refer to the ATV66 user manual VD0C06S305C page 61.
CTA-ID : 2018068
Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors
Product Line:
IEC Contactors and Starters
Environment:
Tesys D Contactors
Resolution:
For contactors with screw clamp terminals:
stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
stranded cable w/cable end: One or Two #18-10 AWG per terminal.
solid cable: One or Two #18-8 AWG per terminal.