TeSys D Reversing Contactor TeSys Deca, 3P(3 NO), AC-3, 0 to 440V, 65A, 48 to 130VAC/DC coil
Item Number: LC2D65AEHE
Specifications
Design
Range of product
Product or component type
Warranty
Physical
Device presentation
[ue] rated operational voltage
[ie] rated operational current
- 80 A (at <60 °C) at <= 440 V AC-1 for power circuit
- 65 A (at <60 °C) at <= 440 V AC-3 for power circuit
Mounting support
- rail
- plate
Connections - terminals
- control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
- control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
- control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
- control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
- control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid
- control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid
- power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible without cable end
- power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible without cable end
- power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible with cable end
- power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible with cable end
- power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²solid
- power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²solid
Insulation resistance
Ip degree of protection
Climatic withstand
- conforming to IACS E10
- conforming to IEC 60947-1 Annex Q category D
Ambient air temperature for operation
- -40...60 °C
- 60...70 °C with derating
Ambient air temperature for storage
Height
Width
Depth
Net weight
Mercury free
Rohs exemption information
Environmental disclosure
Eu rohs directive
Reach regulation
Reach regulation
China rohs regulation
Eu rohs directive
China rohs regulation
Others
Life cycle assessment data
Substance regulation data deliverable
Average percentage of recycled plastic content
Package 1 bare product quantity
Warranty duration(in months) bmecat
Legacy weee scope
Weee label
Product name
Device short name
Contactor application
- motor control
- resistive load
Utilisation category
- AC-1
- AC-3
Poles description
Pole contact composition
Motor power kw
- 18.5 kW at 220...230 V AC 50 Hz
- 30 kW at 380...400 V AC 50 Hz
- 37 kW at 415 V AC 50 Hz
- 37 kW at 440 V AC 50 Hz
- 37 kW at 500 V AC 50 Hz
- 37 kW at 660...690 V AC 50 Hz
Motor power hp
- 5 hp at 115 V AC 60 Hz for 1 phase motors
- 10 hp at 230/240 V AC 60 Hz for 1 phase motors
- 20 hp at 200/208 V AC 60 Hz for 3 phases motors
- 20 hp at 230/240 V AC 60 Hz for 3 phases motors
- 40 hp at 460/480 V AC 60 Hz for 3 phases motors
- 50 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit type
- AC at 50/60 Hz AC/DC electronic
- DC AC/DC electronic
[uc] control circuit voltage
- 48...130 V AC 50/60 Hz
- 48...130 V DC
Auxiliary contact composition
[uimp] rated impulse withstand voltage
Overvoltage category
[ith] conventional free air thermal current
- 10 A (at 60 °C) for signalling circuit
- 80 A (at 60 °C) for power circuit
Irms rated making capacity
- 140 A AC for signalling circuit conforming to IEC 60947-5-1
- 250 A DC for signalling circuit conforming to IEC 60947-5-1
- 1000 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
[icw] rated short-time withstand current
- 100 A - 1 s for signalling circuit
- 120 A - 500 ms for signalling circuit
- 140 A - 100 ms for signalling circuit
- 520 A 40 °C - 10 s for power circuit
- 900 A 40 °C - 1 s for power circuit
- 110 A 40 °C - 10 min for power circuit
- 260 A 40 °C - 1 min for power circuit
Associated fuse rating
- 10 A gG for signalling circuit conforming to IEC 60947-5-1
- 125 A gG at <= 690 V coordination type 1 for power circuit
- 125 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
[ui] rated insulation voltage
- power circuit: 690 V conforming to IEC 60947-4-1
- signalling circuit: 690 V conforming to IEC 60947-1
Power dissipation per pole
- 9.6 W AC-1
- 6.3 W AC-3
Protective cover
Interlocking type
Tightening torque
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
- power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm
- power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm
Safety reliability level
- B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
- B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Maximum operating rate
Coil technology
Control circuit voltage limits
- <= 0.1 Uc (-40-70 °C):drop-out AC/DC
- 0.85...1.1 Uc (-40-60 °C):operational AC/DC
- 1...1.1 Uc (60-70 °C):operational AC/DC
Auxiliary contacts type
- type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
- type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency
Minimum switching current
Minimum switching voltage
Non-overlap time
- 1.5 ms on de-energisation between NC and NO contact
- 1.5 ms on energisation between NC and NO contact
Compatibility code
Maximum motor phase current
Rated thermal current (ith)
[uc] control circuit voltage
Protective treatment
Pollution degree
Operating altitude
Fire resistance
Flame retardance
Mechanical robustness
- vibrations contactor open: 2 Gn, 5...300 Hz
- vibrations contactor closed: 4 Gn, 5...300 Hz
- shocks contactor open: 10 Gn for 11 ms
- shocks contactor closed: 15 Gn for 11 ms
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Green premium status for reporting
Total lifecycle carbon footprint
Carbon footprint of the manufacturing phase [a1 to a3]
Carbon footprint of the manufacturing phase [a1 to a3]
Carbon footprint of the distribution phase [a4]
Carbon footprint of the distribution phase [a4]
Carbon footprint of the installation phase [a5]
Carbon footprint of the installation phase [a5]
Carbon footprint of the use phase [b2, b3, b4, b6]
Carbon footprint of the use phase [b2, b3, b4, b6]
Sustainable packaging
Carbon footprint of the end-of-life phase [c1 to c4]
Carbon footprint of the end-of-life phase [c1 to c4]
Halogen-free status
F-gas free
Take-back
Product contributes to saved and avoided emissions
Removable battery
Total lifecycle carbon footprint
Average percentage of recycled metal content
Packaging made with recycled cardboard
Packaging without single use plastic
Scip number
Halogen-free status
End of life manual availability
Take-back
Weee label
Warranty (in months)
Documents & downloads
-
All
-
Product Brochures
-
CAD Files and Packs
-
Technical Data Catalogues
-
Environmental Disclosure
-
End of Life Manual
-
Installation Instruction
-
Technical illustration
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)