Harmony Timer Relays Modular timing relay 8A, 1CO, 1s..100h, single interval relay, 24V DC 24...240V AC DC
Item Number: RE17RBMU
Specifications
Design
Range of product
Product or component type
Physical
Width
Connections - terminals
[in] rated current
Height
Depth
Control type
Connections - terminals
- screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
- screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
- screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
- screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Insulation resistance
Electrical durability
Mechanical durability
Marking
Mounting position
Mounting support
Local signalling
- LED indicator for on steady: relay energised, no timing in progress
- LED indicator for flashing: timing in progress 80 % ON and 20 % OFF
- LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFF
Function available
Net weight
Control type
Standards
- 2006/95/EC
- IEC 61000-6-2
- IEC 61000-6-3
- IEC 61000-6-4
- IEC 61812-1
- IEC 61000-6-1
- 2004/108/EC
Product certifications
- GL
- cULus
- CSA
Ambient air temperature for storage
Ambient air temperature for operation
Ip degree of protection
- IP20 (terminal block) conforming to IEC 60529
- IP40 (housing) conforming to IEC 60529
- IP50 (front panel) conforming to IEC 60529
Relative humidity
Mercury free
Rohs exemption information
Environmental disclosure
Eu rohs directive
Reach regulation
China rohs regulation
California proposition 65
Material
Contacts material
Others
Package 1 bare product quantity
Legacy weee scope
Average percentage of recycled plastic content
Weee label
Discrete output type
Device short name
Time delay type
Time delay range
- 10...100 h
- 1...10 min
- 6...60 min
- 1...10 s
- 6...60 s
- 1...10 h
- 0.1...1 s
Nominal output current
[uc] control circuit voltage
- 24 V
- 24...240 V
Output type
Contacts type and composition
[us] rated supply voltage
- 24...240 V AC 50/60 Hz
- 24 V DC
Voltage range
Supply frequency
Input voltage
Tightening torque
Housing material
Repeat accuracy
Temperature drift
Voltage drift
Setting accuracy of time delay
Time delay type
Impulse duration
- 100 ms with load in parallel typical
- 30 ms typical
Reset time
On-load factor
Power consumption in va
Maximum power consumption in w
Minimum switching current
Maximum switching current
Maximum switching voltage
Breaking capacity
Operating rate in hz
Dielectric strength
[uimp] rated impulse withstand voltage
Maximum delay response
Creepage distance
Safety reliability data
- MTTFd = 296.8 years
- B10d = 270000
Number of functions
Time delay type
Functionality
Compatibility code
Immunity to microbreaks
Vibration resistance
Shock resistance
Electromagnetic compatibility
- electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
- electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
- susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
- electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
- electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
- 1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
- 1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
- conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
- voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
- voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
- conducted and radiated emissions: , class B, conforming to EN 55022
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Total lifecycle carbon footprint
Carbon footprint of the manufacturing phase [a1 to a3]
Carbon footprint of the manufacturing phase [a1 to a3]
Carbon footprint of the distribution phase [a4]
Carbon footprint of the distribution phase [a4]
Carbon footprint of the installation phase [a5]
Carbon footprint of the installation phase [a5]
Carbon footprint of the use phase [b2, b3, b4, b6]
Carbon footprint of the use phase [b2, b3, b4, b6]
Sustainable packaging
Carbon footprint of the end-of-life phase [c1 to c4]
Carbon footprint of the end-of-life phase [c1 to c4]
Take-back
Product contributes to saved and avoided emissions
Removable battery
Total lifecycle carbon footprint
Average percentage of recycled metal content
Packaging made with recycled cardboard
Packaging without single use plastic
Scip number
End of life manual availability
Take-back
Warranty (in months)
Documents & downloads
hide show-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Environmental Disclosure
-
End of Life Manual
-
Installation Instruction
-
Handout
-
Technical illustration
-
eTechPub
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)