MASTER YOUR CASTLE with your new build or reno project
Enter competition
Star-delta starter LC3D32 for motor control

LC3D32AF7

TeSys D Star Delta Starter, 3 x 3P (3 NO), 32A, 110VAC Coil

Star-delta starter LC3D32 for motor control
Colour:
Colour: Per UOM Std.
  • 1 PCE
Added to cart
Successfully added, you can view your cart here

Key Features & Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
star delta starter
Device short name
LC3D
Contactor application
motor control
Utilisation category
AC-3
Device presentation
pre-wired
Poles description
3 x 3P
Pole contact composition
3 x 3 NO
[Ue] rated operational voltage
power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current
32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
Motor power kW
  • 15 kW at 220/230 V AC 50/60 Hz
  • 25 kW at 380/400 V AC 50/60 Hz
  • 30 kW at 415 V AC 50/60 Hz
  • 30 kW at 440 V AC 50/60 Hz
    • Control circuit type
      AC at 50/60 Hz
      [Uc] control circuit voltage
      110 V AC 50/60 Hz
      Auxiliary contact composition
      1 NC for KM1 star contactor
      [Uimp] rated impulse withstand voltage
      6 kV conforming to IEC 60947
      Overvoltage category
      III
      [Ui] rated insulation voltage
    • power circuit: 690 V conforming to IEC 60947-4-1
    • power circuit: 600 V CSA certified
    • power circuit: 600 V UL certified
    • signalling circuit: 690 V conforming to IEC 60947-1
    • signalling circuit: 600 V CSA certified
    • signalling circuit: 600 V UL certified
      • Electrical durability
        1.65 Mcycles 32 A AC-3 at Ue <= 440 V
        Provided equipment
        protective cover
        Interlocking type
        mechanical
        Mounting support
        plate
        Standards
      • EN 60947-5-1
      • EN 60947-4-1
      • UL 508
      • CSA C22.2 No 14
      • IEC 60947-4-1
      • IEC 60947-5-1
        • Product certifications
        • RINA
        • GL
        • GOST
        • BV
        • DNV
        • CCC
        • CSA
        • LROS (Lloyds register of shipping)
        • UL
          • Connections - terminals
          • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
          • power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end
          • power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid without cable end
          • power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid without cable end
          • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
          • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
          • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
          • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
          • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
          • power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end
          • power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end
          • power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end
            • Tightening torque
            • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
            • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
            • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
            • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
              • Mechanical durability
                15 Mcycles
                Maximum operating rate
                30 cyc/h 60 °C
                Starting time
                30 s
                Coil technology
                without built-in suppressor module
                Control circuit voltage limits
              • drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C)
              • operational: 0.8...1.1 Uc at 50 Hz (at <60 °C)
              • operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
                • Inrush power in VA
                • 70-70 VA 60 Hz cos phi 0.75 (at 20 °C)
                • 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
                  • Hold-in power consumption in VA
                  • 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
                  • 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
                    • Heat dissipation
                      2-3 W at 50/60 Hz
                      Auxiliary contacts type
                    • mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC
                    • mirror contact conforming to IEC 60947-4-1 3 x 1 NC
                      • Signalling circuit frequency
                        25...400 Hz
                        Minimum switching current
                        5 mA for signalling circuit
                        Switching voltage
                        17 V for signalling circuit
                        Non-overlap time
                      • 1.5 ms on de-energisation between NC and NO contact
                      • 1.5 ms on energisation between NC and NO contact
                        • Width
                          166 mm
                          Height
                          124 mm
                          Depth
                          149 mm
                          Net weight
                          2.03 kg
                          Power range
                        • 15-25 kW at 380-440 V 3 phases
                        • 15-25 kW at 200-240 V 3 phases
                        • 30-50 kW at 380-440 V 3 phases
                          • Motor starter type
                            star delta starter
                            Contactor coil voltage
                            110 V AC standard
                            Insulation resistance
                            > 10 MOhm for signalling circuit
                            IP degree of protection
                            IP20 front face conforming to IEC 60529
                            Protective treatment
                            TH conforming to IEC 60068-2-30
                            Pollution degree
                            3
                            Ambient air temperature for storage
                            -60-80 °C
                            Ambient air temperature for operation
                            -40-70 °C at Uc
                            Operating altitude
                            3000 m without
                            Fire resistance
                            850 °C conforming to IEC 60695-2-1
                            Flame retardance
                            V1 conforming to UL 94
                            Mechanical robustness
                          • vibrations contactor open: 2 Gn, 5...300 Hz
                          • vibrations contactor closed: 4 Gn, 5...300 Hz
                          • shocks contactor closed: 15 Gn for 11 ms
                          • shocks contactor open: 8 Gn for 11 ms
                            • Sustainable offer status
                              Green Premium product
                              REACh Regulation
                              Reference contains Substances of Very High Concern above the threshold
                              REACh free of SVHC
                              Yes
                              EU RoHS Directive
                              Pro-active compliance (Product out of EU RoHS legal scope)
                              Toxic heavy metal free
                              Yes
                              Mercury free
                              Yes
                              RoHS exemption information
                              Yes
                              China RoHS Regulation
                              X
                              Environmental Disclosure
                              ENVPEP1501004EN
                              Circularity Profile
                              ENVEOLI1501004EN
                              WEEE
                              The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                              CALIFORNIA PROPOSITION 65
                              WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.p65warnings.ca.gov
                              Warranty
                              18 months

                              Documents & downloads

                              hide show
                              Filter items
                              • All

                              • CAD Files and Packs

                              • Product Brochures

                              • Movies

                              • Technical Data Catalogues

                              • Catalog Page

                              • Technical Leaflet

                              • Product Environmental

                              • End of Life Manual

                              • Handout

                              • Installation Instruction

                              • Data Bulletin

                              • Operating Manuals

                              • Application Solutions

                              • eTechPub

                              • Certificates (MSDS)

                              • Declaration of Conformity

                              • White Paper

                              • Marine Certificate

                              • Software - Released