TeSys D Contactor, 4P(4 NO), AC-1, <= 440V, 200A, 110VAC, 50/60 Hz Coil

TeSys D Contactor, 4P(4 NO), AC-1, <= 440V, 200A, 110VAC, 50/60 Hz Coil

TeSys D Contactor, 4P(4 NO), AC-1, <= 440V, 200A, 110VAC, 50/60 Hz Coil

Item Number: LC1D1150046F7

Retail
$3,404.69
RRP (Inc. GST)

Product Dimensions

Width icon

Width155 mm

Height icon

Height158 mm

Depth icon

Depth115 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 1000 V AC 25...400 Hz
  • power circuit: <= 460 V DC
    • [Ie] rated operational current

      200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

      Electrical durability

      0.8 Mcycles 200 A AC-1 at Ue <= 440 V

      Mounting support

    • rail
    • plate
      • Standards

      • CSA C22.2 No 14
      • EN 60947-4-1
      • EN 60947-5-1
      • IEC 60947-4-1
      • IEC 60947-5-1
      • UL 508
        • Product certifications

        • LROS (Lloyds register of shipping)
        • DNV
        • BV
        • RINA
        • CSA
        • UL
        • CCC
        • GOST
        • GL
          • Connections - terminals

          • control circuit: lugs-ring terminals (external diameter: 8 mm)
          • power circuit: lugs-ring terminals (external diameter: 25 mm)
          • power circuit: bars 1 cable(s) - busbar cross section: 5 x 25 mm
            • Mechanical durability

              8 Mcycles

              IP degree of protection

              IP20 front face conforming to IEC 60529

              Ambient air temperature for storage

              -60-80 °C

              Height

              158 mm

              Width

              155 mm

              Depth

              115 mm

              Net weight

              2.86 kg

              EU RoHS Directive

              Compliant

              Mercury free

              Yes

              RoHS exemption information

              Yes

              China RoHS Regulation

              Product out of China RoHS scope. Substance declaration for your information

              Environmental Disclosure

              ENVPEP060301EN

              Circularity Profile

              ENVEOLI100405EN

              Others

              Product name

              TeSys D

              Device short name

              LC1D

              Contactor application

              resistive load

              Utilisation category

              AC-1

              Poles description

              4P

              Pole contact composition

              4 NO

              Control circuit type

              AC at 50/60 Hz

              [Uc] control circuit voltage

              110 V AC 50/60 Hz

              [Uimp] rated impulse withstand voltage

              8 kV conforming to IEC 60947

              Overvoltage category

              III

              [Ith] conventional free air thermal current

              200 A (at 60 °C) for power circuit

              Irms rated making capacity

              1260 A at 440 V for power circuit conforming to IEC 60947

              Rated breaking capacity

              1100 A at 440 V for power circuit conforming to IEC 60947

              [Icw] rated short-time withstand current

            • 250 A 40 °C - 10 min for power circuit
            • 550 A 40 °C - 1 min for power circuit
            • 950 A 40 °C - 10 s for power circuit
            • 1100 A 40 °C - 1 s for power circuit
              • Associated fuse rating

              • 250 A gG at <= 690 V coordination type 1 for power circuit
              • 200 A gG at <= 690 V coordination type 2 for power circuit
                • Average impedance

                  0.6 mOhm - Ith 200 A 50 Hz for power circuit

                  [Ui] rated insulation voltage

                • power circuit: 600 V CSA certified
                • power circuit: 600 V UL certified
                • power circuit: 1000 V conforming to IEC 60947-4-1
                  • Power dissipation per pole

                    24 W AC-1

                    Protective cover

                    with

                    Tightening torque

                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
                  • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
                  • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
                    • Operating time

                    • 6...20 ms opening
                    • 20...50 ms closing
                      • Safety reliability level

                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                        • Maximum operating rate

                          2400 cyc/h 60 °C

                          Coil technology

                          built-in bidirectional peak limiting diode suppressor

                          Inrush power in VA

                        • 280-350 VA 60 Hz cos phi 0.8 (at 20 °C)
                        • 280-350 VA 50 Hz cos phi 0.8 (at 20 °C)
                          • Hold-in power consumption in VA

                          • 2-18 VA 60 Hz cos phi 0.3 (at 20 °C)
                          • 2-18 VA 50 Hz cos phi 0.3 (at 20 °C)
                            • Heat dissipation

                              3-8 W at 50/60 Hz

                              Contact compatibility

                              M14

                              Compatibility code

                              LC1D

                              Protective treatment

                              TH conforming to IEC 60068-2-30

                              Pollution degree

                              3

                              Operating altitude

                              3000 m without derating

                              Fire resistance

                              850 °C conforming to IEC 60695-2-1

                              Flame retardance

                              V1 conforming to UL 94

                              Mechanical robustness

                            • vibrations contactor open: 2 Gn, 5...300 Hz
                            • vibrations contactor closed: 4 Gn, 5...300 Hz
                            • shocks contactor closed: 15 Gn for 11 ms
                            • shocks contactor open: 6 Gn for 11 ms
                              • Package 1 Weight

                                2.37 kg

                                Package 1 Height

                                1.68 dm

                                Package 1 width

                                2.12 dm

                                Package 1 Length

                                1.85 dm

                                WEEE

                                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                PVC free

                                Yes
                                Show all specifications

                                Documents & downloads

                                hide show
                                Filter items
                                • All

                                • CAD Files and Packs

                                • Product Brochures

                                • Technical Data Catalogues

                                • End of Life Manual

                                • Installation Instruction

                                • Product Environmental

                                • Declaration of Conformity

                                • Certificates (MSDS)

                                Frequently Asked Questions

                                hide show

                                What code is a mechanical interlock for the 4pole LC1D1150046 contactor?

                                LA9D11502 will fit the 4p LC1D115 and LC1D150 contactors

                                Are the D-Line contactors rated to break DC voltages?

                                Issue: 
                                Can the TeSys D line be used to control DC loads? 

                                Product Line:
                                Tesys D contactors

                                Environment:
                                Products sold and used in the United States
                                 
                                Cause:
                                 DC power circuit
                                 
                                Resolution:
                                 
                                Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                Devices are suitable but not UL Listed for DC applications.

                                More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                 

                                Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

                                Issue:
                                Auxiliary contact modules for the LC1D and LC2D contactors

                                Product Line: 
                                Contactor and Starters - IEC

                                Environment:
                                North American Products

                                Resolution:
                                Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
                                Front Mounting; maximum of 1 block per contactor:

                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                --1-----------1---------LADN11-----------LA1DN11
                                --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
                                --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
                                --2-----------0---------LADN20-----------LA1DN20
                                --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
                                --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
                                --0-----------2---------LADN02-----------LA1DN02
                                --2-----------2---------LADN22-----------LA1DN22
                                --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
                                --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
                                --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
                                --3-----------1---------LADN31------------LA1DN31
                                --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
                                --1-----------3---------LADN13------------LA1DN13
                                --4-----------0---------LADN40------------LA1DN40
                                --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
                                --0-----------4---------LADN04------------LA1DN04




                                Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                --1-----------0--------LADN10----------LA1DN10
                                --0-----------1--------LADN01----------LA1DN01

                                Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
                                (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                --1-----------1--------LAD8N11----------LA8DN11
                                --2-----------0--------LAD8N20----------LA8DN20
                                --0-----------2--------LAD8N02----------N/A

                                Footnotes:
                                {1} EN50 012 Machine Tool Terminal Markings
                                {2} (2) NO Sealed Dust Tight Contacts
                                {3} Gold Flash Contacts
                                {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
                                {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
                                {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts

                                What is the color scheme of the Tesys D-Line contactors?

                                Issue:
                                Looking for different color scheme of the Tesys D-Line contactors.

                                Product Line:
                                Tesys D Contactors

                                Environment:
                                LC1D contactors

                                Resolution:
                                Beige and dark gray.
                                 

                                What are the stand alone short circuit current ratings on the LC1D** contactors?

                                Issue:
                                Tesys D SCCR

                                Product Line:
                                Contactors and Overload Relays

                                Environment:
                                TeSys™ D Contactors and Overload Relays
                                 
                                Resolution:
                                The contactors have a stand alone withstand rating that has been established by UL and is based on the maximum horsepower rating for a given device. However, only combination type starters are supplied with short circuit protective devices having a short circuit current rating.

                                They are as follows:
                                Horsepower SCCR (A)

                                0 thru 1 1,000
                                1 thru 50 5,000
                                51 thru 200 10,000
                                201 thru 400 18,000
                                401 thru 600 30,000
                                601 thru 900 42,000
                                901 thru 1600 85,000
                                1601+ 100,000

                                What are the coil voltage codes for the LC1D115 / LC2D115 and LC1D150 / LC2D150 TeSys contactor?

                                Issue:
                                LC1D115 / LC2D115 and LC1D150 / LC2D150

                                Product Line:
                                Tesys D line Contactors

                                Environment:
                                North America

                                Resolution:
                                The following list the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

                                Note 1: LC1D150 contactors are only available with *7 coil codes.
                                Note 2: Coil Code ending number represents frequency rating as follows:
                                5 = 50 Hertz
                                6 = 60 Hertz
                                7 = 50/60 Hertz

                                AC Volts ___Code                DC Volts ___Code
                                24 ___ B5 or B6 or B7          12 ___ Not Avail.        
                                42 ___ D5 or D7                   24 ___ BD
                                48 ___ E5 or E6 or E7          36 ___ CD
                                110 ___ F5 or F6 or F7         48 ___ ED
                                115 ___ FE5 or FE7             60 ___ ND
                                120 ___ G6 or G7                72 ___ SD
                                127 ___ FC5 or FC7            110 ___ FD
                                208 ___ L6 or LE7               125 ___ GD
                                220 ___ M5 or M6 or M7       220 ___ MD
                                230 ___ P5 or P7                 250 ___ UD
                                240 ___ U5 or U6 or U7        440 ___ RD
                                277 ___ W6 or UE7                
                                380 ___ Q5 or Q6 or Q7                
                                400 ___ V5 or V7                
                                415 ___ N5 or N7                
                                440 ___ R5 or R6 or R7                
                                480 ___ T6 or T7                
                                500 ___ S5 or S7                


                                 

                                What replaces the LC1D12004M7 contactor?

                                What is the part number for a replacement 4 pole 25amp contactor for the LC1D12004B7?

                                The part number for a replacement 4 pole 25amp contactor for the LC1D12004B7 is - LC1DT25B7

                                For further information, visit the link below:-
                                https://www.schneider-electric.com.au/en/search/LC1DT25B7
                                User-added image

                                 

                                What is the difference between the LC1D1506N7 and the LC1D150N7?

                                The LC1D1506N7 can accept 5X25mm Bars aswell as Lugs or ring terminals. The LC1D150N7 only accepts cable lugs upto 120mm2.

                                Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

                                Issue:
                                Can new accessories be used on older style contactors

                                Product Line:
                                IEC contactors and starters

                                Environment:
                                Products sold and used in the United States

                                Cause:
                                Identifying product compatibility

                                Resolution:
                                Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


                                 

                                Does the LC1D1156U7 come with 1NO & 1NC Aux contact

                                Yes - all the D range contactors have one of each aux contact

                                What is the replacement contactor for the LC1D65004F5?

                                The new code is LC1DT80AF7 which is made to order.
                                Show More