connector strip 20amp

Max 4 Strip Connectors, 20A, 12 Terminal, Double Entry Bakelite

Catalogue Number: BP2
connector strip 20amp
Retail
N/A
RRP (Inc. GST)

Specifications

hide show
Product brand
Clipsal
Range of product
Blue Point
Cable cross section
4-4 mm² fine stranded without cable end sleeve
[In] rated current
20 A
Connector type
  • 1 screw terminals
  • 2 screw terminals
    • Number of poles
      12
      Mounting support
      panel
      Material
      bakelite: insulation
      Width
      17 mm grid pattern:
      Minimum mounting height
      16 mm
      Length
      122 mm
      Ambient air temperature for operation
      190 °C
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information

      Frequently Asked Questions

      hide show

      What are the Clipsal BPT2 Dimensions?

      • Dimensions: 58 x 40 x 40 mm
      https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=BPT2

      What is a bPF fault on the ATS22 soft starter?

      Issue:
      What is a bPF fault on the ATS22 soft starter?

      Product Line:
      Altistart ATS22

      Environment:
      All

      Cause:
      Bypass contactor detected fault

      Resolution:
      Check for a welded bypass contactor or shorted SCR.
      If you find a shorted SCR or bypass contactor, you will need to replace the soft starter.
      Reference the manual BBV51330 of ATS22 installation guide.

      What is the part number for a BPA sign in the Medilec range?

       The part number for a BPA sign in the Medilec range is SIGN/BPA.

      Some of the key features are:

      • Made from sturdy laminex
      • Adhesive on each corner for easy installation
      • Supplied with “test and date” stickers

       

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=SIGN/BPA

       

      Can BPH motors be used with the Lexiium 32 Servo drives?

      Yes, the BPH motors are compatible with Lexium 32 servo drives. They are to be characterized as third party motors.  If using a BPH motor with resolver, you will need to use a resolver option card P/N : VW3 M3 401. If using a BPH motor with encoder feedback, you will need to use an encoder option card.VW3 M3 403 (for hiperface encoder) along with a Lexum 32 modular drive (32M). The third party motor commissioning tool within SoMove helps calculate the offset to commutate the motor.

      What can prevent an OP2 fault code on an ATV212 drive?

      Issue:
      What can prevent an OP2 fault code on an ATV212 drive?

      Product Line:
      ATV21, ATV212

      Environment:
      All models and serial numbers

      Cause:
      The OP2 fault is caused by overvoltage during deceleration

      Resolution:
      1.  Increase the deceleration time (increase dEC).
      2.  Disable Auto Ramp Adaptation (Set AU1 to 0). Auto ramp adaptation can cause fluctuation on the line supply to the drive.
      3.  Measure drive DC bus (PA/+ to PC/-) with a meter.  
      4.  Check for load issue that can cause back feeding issue to DC bus such as stopping a load very quickly.
      Stopping one fan while another fan is pulling on it (such as in a wind tunnel) can cause back feeding into the DC bus.

      Note: A dynamic braking resistor cannot be added to the ATV212 drive. 

      MHDA1056N00 servo drive replacement

      Question:
      Replacement for the MHDA1056N00 drive

      Product Line:
      MHDA

      Resolution:
      The MHDA1056N00 servo drive is obsolete.
      The closest match is the LXM32MC10N4 (11kW instead of 14kW)
      The BPH motor will also have to be replaced.

      Looking for servo motor BPH190AK5MA2CA1

      Issue:
      Looking for servo motor BPH190AK5MA2CA1

      Product:
      Lexium BPH motors

      Resolution:
      This family of motors is obsolete. 
      The best option is to contact our service department at:
      Toll Free: +800-468-5342 ext. Opt #2
      Fax: +978-975-9425, Attention Dave D.
      Email: service.sales@schneider-electric.com

      SEPAM Series 20 Wiring Diagram

      Issue  
      Need the wiring diagram for the SEPAM 20.

      Product Line   
      SEPAM Series 20

      Resolution   
      Attached is the wiring diagram for the all SEPAM Series 20.

      Is SoMachine V4.1 SP2 compatible with Windows 10?

      Issue:
      SoMachine V4.1 SP2 windows compatibility

      Product Line:
      SoMachine

      Resolution:
      SoMachine V4.1 SP2 only supports Windows 7, 32 and 64 bit, as well as Windows 8.1, 32 and 64 bits.
      SoMachine V4.2 supports it.

      What is the IP protection class for the BPH motor power and feedback cables?

      The only available IP protection for the power and feedback cables is IP 67.


      Legacy KB System (APS) Data: RESL182113 V1.0, Originally authored by TVe on 02/13/2007, Last Edited by TVe on 02/13/2007
      Related ranges: Lexium 17D

      What does BP designate at the end of a 9013F part number?

      Issue:
      What does the form BP mean at the end of a pressure switch part number

      Product Line:
      All Schneider Electric products

      Environment:
      Products sold and used in the United States

      Cause: 
      Customer needs to know what BP stands for at the end of a class 9013 part number.
       
      Resolution:
      The BP at the end of part numbers such as 9013FSG2J20BP calls out for a blister pack, this will come in plastic to hang on a display.

      Keywords:
      9013, 9013 type F, type G 9013F, 9013G, blister pack, form BP, BP, bulk pack

      Cutout diagram for the SEPAM 20.

      Issue  
      Need the cutout diagram for the SEPAM 20.

      Product Line   
      SEPAM Series 20

      Resolution   
      Attached is the cutout diagram for the all SEPAM Series 20.
       
      Show More