label - 5082F-PW
5082F-GF fascia image
label - 5082F-30
label - 5082F-60
2 GANG S-STEEL FACIA
5082F-J0 fascia image
5082F-PW fascia image
label - 5082F-PW
5082F-GF fascia image
label - 5082F-30
label - 5082F-60
2 GANG S-STEEL FACIA
5082F-J0 fascia image
5082F-PW fascia image

Glass Fascia, 2 Gang, Saturn Series, Rectangular

Catalogue Number: 5082F
label - 5082F-PW
5082F-GF fascia image
label - 5082F-30
label - 5082F-60
2 GANG S-STEEL FACIA
5082F-J0 fascia image
5082F-PW fascia image
label - 5082F-PW
5082F-GF fascia image
label - 5082F-30
label - 5082F-60
2 GANG S-STEEL FACIA
5082F-J0 fascia image
5082F-PW fascia image
Retail
$101.89
RRP (Inc. GST)
Colour Pure White (PW)
  • Pure White 1 PCE
  • Cream 1 PCE
  • Black 1 PCE
  • Glass Finish 1 PCE
  • Stainless Steel 1 PCE

Specifications

hide show
Range of product
  • Saturn Series
  • Australian Series
  • C-Bus
    • Range
      C-Bus
      Product brand
      Clipsal
      Number of gangs
      2 gangs
      Product destination
      switch
      Material
      glass
      Control type
      button
      Marking
      without marking
      Mounting position
      vertical
      Fixing center
      84 mm
      Length
      116 mm
      Width
      76 mm
      Depth
      12 mm
      Package 1 Weight
      97 g
      Package 1 Height
      18 mm
      Package 1 width
      107 mm
      Package 1 Length
      145 mm
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Circularity Profile
      ENVEOLI121001EN

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Technical Leaflet

      • Installation Instruction

      • End of Life Manual

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      Does a 5082NL need CBus to operate

      Yes it does

      Does the 5082NL fascia come complete with the buttons?

      The 5082NL fascia does not come complete with the buttons. If you require the buttons you will need to buy the entire unit.
      Some of the key features are:
      • 2 gang
      • Glass fascia
      • Mounting centres: 84 mm
      • Operating temperature range: 0 to 45 deg C
      • Dimmer control: 255 possible levels
      • Dimensions: rectangle 116 x 76 mm
      • C-bus connection: one terminal block to accommodate 0.2 - 1.5 sq mm(24-16 AWG)
      • An inbuilt non-volatile memory retains programmed information of the unit in the event of a power failure
      • LED gang indicators provide illumination and status feedback
      • programmed via learn mode or the c-bus toolkit software
      • C-bus learn enabled
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=5082NL


       

      What is the part number for the Fascia only on a Cbus Saturn 4 gang plate ?

      The part number will be 5084F- and then colour reference eg 5084F-PW for Pure White Fascia

      How to return a Smart-UPS or Back-UPS product for Warranty Replacement.

      Issue:

      You  are having a technical issue with your UPS and feel that it should be returned for warranty service

      Product Line:

      All single phase UPS products

      Environment:

      All models, All Serial Numbers

      Cause:

      UPS is not functioning as expected

      Resolution:

      The first step in returning a unit for replacement under warranty is to contact APC Tech Support to troubleshoot the issue. Troubleshoting is required for Warranty service. You can find contact information here. If a return is deemed necessary, the Tech Support Engineer will place the order for your replacement unit and provide an RMA (Return Merchandise Authorization) number and shipping address to return the defective equipment to. 

      When shipping the UPS back to APC, it is important to perform the following steps:

      • Make sure the Battery in the UPS is disconnected. This is very important to guarantee the safe shipment of the unit and to meet all Department of Transportation regulations. 
      • Package the unit securely, preferably using the original shipping box. If the original shipping box is unavailable make sure that the packing materials used are sufficient for the weight of the UPS.
      • Clearly label the box with the RMA number provided by Tech Support. This number is used to track the return of your unit once it reaches our warehouse.

      In the US and Canada, replacement units will ship out via ground carrier such as FedEx, UPS, or Purolator. Units replaced under an Extended Warranty ship out via standard overnight delivery. RMA's processed before 2pm generally ship out the same day, assuming that the replacement part is in stock. Within 30 days of purchase, all warranty replacements will be new product. After 30 days, replacement units will be refurbished product. New product may be substituted if refurbished units are unavailable. All refurbished units are fully tested to ensure that they meet all factory specifications and include a new battery. 

      If you need to contact APC for additional information regarding your RMA, please have you RMA or case number available to expedite the request. 

      PowerSCADA Expert - Maximum number of IODevices of MODNET type

      Customer request:
      To integrate in the PowerSCADA Expert (PSE) project 400 sets of Ethernet devices which support Modbus TCP protocol.
      The question was if all the devices can be integrated to one PSE Server, and the SCADA system is redundant.
      In the legacy software version, one IOServer could only have one TCP/IP Board and 255 Ports can be created on that type of Board.
      Can we integrate all the devices into one PSE Server? If yes, then how to configure the communication including IO Server, Board, Port and IODevice?

      Resolution:
      The maximum limit in PowerSCADA software is of 16383 IODevices per project and 4095 simultaneous multiple protocols.
      BOARD types have to be unique per IOServer.
      You may find reference of the word "Channel" in various documentation resources.
      To be clear, PORT = Channel.
      PORT number limits are hardcoded into each communication driver.
      The TCPIP driver (TCPIP.DLL) supports 512 PORTS per board since DLL version 2.4.4.0, thus MODNET driver (MODNET.DLL) supports 512 PORTS (channels) since driver version 2.6.21.0.

      These limits are theoretical limits, in reality there are Kernel Queues that introduce another limitation.
      [Kernel]Queue has a max of 5000 (which is also default value), but some drivers like Modnet consume more queues per channel than others.
      Modnet consumes 13 Kernel Queues per PORT.
      As a result, a 512 hardcoded limit for Modnet PORTs will be downgraded to 300-350 because of these queues.
      So, consider the limit at 350 MODNET PORTS per BOARD (per IOServer).
      If you use ModbusTCP/RTU Gateways, then you can have thousands of IODevices on the same IOServer, just because for each of the 350 PORTS you could have several different IODevices, with different Addresses (UnitID).
      For example: 1 Gateway to collect 5 SEPAMs means: 5 IODevices (5 different IODevice Addresses), 1 PORT (the same PORT that uses Special Options for Gateway's IP address), 1 BOARD (TCPIP).

      To overcome the 350 PORTS limit, more IOServers are needed.

      Further, another reduction should be made, imposed by the recommended number of IODevices per IOServer.
      In the same project, the same Cluster, the same Network Address, the PowerSCADA team recommendation (rule) is: either 50000 tags or 250 IODevices per IOServer. Whichever comes first.
      To create another IOServer in the same Cluster and the same Network Address, simply add another IOServer but specify a different Port (this is the Port from the IO Server dialog window).
      Doing so, you will need to define different Ports for the extra IOServers: default is 2082, so you may add any unused TCP port: 3082 for second IOServer, 4082 for third IOServer and so on.

      Here are some configuration screenshots (using Excel and DBF Add-in) to illustrate the IODevices distribution per IOServers:

      IOServers:


      Boards:


      Ports:


      IODevices:



                                                  
      Created on 8th JUL 2015 by
      Adrian Dicea
      Global Expert Technical Support Engineer - Support Prime PSE / EGX