Grid Socket Horiz Single 10A 250V

Clipsal Iconic - Single Switch Socket Outlet Grid, Horizontal Mount, 250V, 10A

Catalogue Number: 3015G
Grid Socket Horiz Single 10A 250V
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range
Clipsal Iconic
Product or component type
switched socket
Device presentation
mechanism with fixing frame
Outlet poles configuration
2P + E with shutter
Device mounting
flush
Number of power socket outlets
1
Number of rocker
1
Range compatibility
cover frame
Outlet standard
Australian
Outlet standard description
with earthing contact
Outlet standard
Australian/New Zealand
Ground lug position
straight 180° position
Fixing mode
by screw
Installation direction
horizontal
Surface finish
matt
Type of packing
polybag
Quantity per set
set of 10
Sale per indivisible quantity
1
Rated current
10 A at 250 V AC 50 Hz
Electrical durability
12000 cycles
Connections - terminals
3 screw terminals
Screwdriver shape
  • Philips No 2
  • square drive no 1 (SQ1)
    • Clamping connection capacity
    • 1 x 2.5...4 x 2.5 mm² for rigid cable(s)
    • 1 x 2.5...4 x 2.5 mm² for stranded cable(s)
    • 1 x 2.5...4 x 2.5 mm² for flexible cable(s)
      • Wire stripping length
        16 mm
        Material
      • PC (polycarbonate): fixing frame
      • PP (polypropylene): rocker
      • POM (polyoxymethylene): shutter
        • Height
          71 mm
          Width
          115 mm
          Depth
          31 mm
          Embedding depth
          23 mm
          Net weight
          0.82 kg
          Ambient air temperature for operation
          0-45 °C
          Relative humidity
          10-95 %
          Standards
          AS/NZS 3112
          Product certifications
          RCM
          Sustainable offer status
          Green Premium product
          EU RoHS Directive
          Compliant
          Toxic heavy metal free
          Yes
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
           Pro-active China RoHS declaration (out of China RoHS legal scope)
          Environmental Disclosure
          ENVPEP120506EN
          Circularity Profile
          N/A

          Documents & downloads

          hide show
          Filter items
          • All

          • Product Brochures

          • Technical Data Catalogues

          • Technical Leaflet

          • Product Environmental

          • Installation Instruction

          • Operating Manuals

          • Certificates (MSDS)

          Frequently Asked Questions

          hide show

          Are EasyPact CVS circuit breakers for sale in the USA or Canada?

          Product Line:
          EasyPact CVS circuit breakers

          Cause:
          This breaker is popular overseas and there is interest in the US

          Resolution:
          There are no plans for a general release of the EasyPact CVS circuit breaker line in North America.

          Do you have an Iconic outlet with round earth?

          No, we do not have a 3015 with a round earth pin.

          For further information please visit https://www.clipsal.com/Trade



           

          What is the replacement for part number 30M15?

          The replacement for part number 30M15 is 30USM. 30USM is an universal rocker mechanism rated to 20A / 16AX, 250V, 1 way / 2 way.
          For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USM
          User-added image

          Can part number 2015X accommodate TV mech?

          A TV mech CAN NOT be put into 2015X. Must have at least 150mm of separation.
           

          What are the mounting centers for the 3015/4 quad outlet?

          ​The mounting centers for the 3015/4 quad outlet is 179.8mm.

          Will the 9013G pressure switches accept stranded wire?

          Issue:
          Will the 9013G pressure switches accept stranded wire?

          Product Line:
          Type G—Pumptrol Pressure Switch

          Environment:
          Commercial Pressure Switches

          Resolution:
          9013G will accept stranded wire.

          Is mech removable in part number 2015X?

          Yes, the mech in part number 2015X is removable.

          For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=2015X


          User-added image

          Do the switches in Iconic switched socket outlet have LED indicators, example 3025?

          There are no LED indicators on the switches in Iconic switched socket outlet. The switches on the outlet have green markings so you know when it is switched ON.

          For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3025



           

          Is there a wall box to suit 3015/4 ICONIC quad outlet?

          No unfortunately there is no wall box to suit 3015/4 ICONIC quad outlet.

          The only mounting accessory available for the 3015/4 is a 3155H4 which is a stud bracket.

          For further information on our product range please visit Trade - Clipsal by Schneider Electric



           

          Wiser Power Monitor Installation Instructions

          Issue:
          Where can I find installation documentation for Wiser Power Monitors, WISERJLPM200, WISERCTPM200?

          Product Line:
          Wiser Home Managerment System

          Environment:
          Residential Home
          https://www.wiserenergy.com

          Cause:
          End user or installer in need of documentation 

          Resolution:
          There are 2 Wiser Power Meters.  
          The "JL" model, WISERJLPM200, has a Jetlun logo on it.  It was sold from 2013 to early 2015.  In first quarter 2015, it was replaced by WISERCTPM200.

          Documentation is attached.
           

          Mounting bracket for 9012G pressure switches

          Issue:

          Is there a mounting bracket available for 9012G switches?

          Product Line:

          9012G Industrial Pressure Switches

          Environment:

          US Product

          Cause:

          Switches may need to be mounted in locations where the standard mounting holes are not usable.

          Resolution:

          Some of the 9012G switches can be ordered with an alternate back which has different mounting holes.  One would need to use form F to gain this backing on a standard switch.  This option is only available on select models and cannot be ordered separately.  Dimensions are attached.

          What is the mounting bracket to suit part number 3015/4?

          The part number is 3155H4 at this stage anticipated release is December 2016.

          What is part number for Iconic cover to suit 3015/4?

          The part number for Iconic cover to suit is 3015/4C.

          What are the dimensions for a PDL Thermosafe heater?

          PDL no longer supplies the Thermosafe range, or any heating appliances.

          255 x 362 is the cutout size for the flush mount box.
          See attached pdf for more.

           

          what is the part number for cover for the 4015?

          The part number for cover for the 4015 is 4015C
          For further information, please visit:
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=4015C

          User-added image

          What is the part number for the ICONIC night walk?

          The part number for the ICONIC night walk is a 3025NW. which is only the cover/sensor light. You will also need the grid which is a 3025G.

          Does the Anthracite Skin for the 3015/4 come with Anthracite Dollies?

          Yes, the dollies are included and the same colour as the skin.

          For more information, please refer to the link:
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=3015/4C-WY 



           

          What is the replacement for ACW-1 pressure switch?

          The replacement for ACW-1 pressure switch is 9012GAW5
           9012GAW5 pressure switch 9012G - adjustable scale - 2 thresholds - 3.0 to 150 psig
          9012GAW5
          pressure switch 9012G - adjustable scale - 2 thresholds - 3.0 to 150 psig

          For more information see;https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=9012GAW5

          Is there a single gang GPO with round earth in the Saturn range?

          Yes we have the 4015L in the Saturn range.

          For more information, please refer to the link:
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=4015L 

          What is the part number for a 6 gang switch for the Iconic range?

          The part number for a 6 gang switch for the Iconic range is - 3046G & 3046C

          For further information , visit link below:-
          https://www.clipsal.com/Trade/search-results?q=3046G
          https://www.clipsal.com/Trade/search-results?q=3046C
          User-added image

          User-added image

           

          Is an adjustment and or troubleshooting guide offered for the 9013F or 9013G products?

          Issue:
          Locating documentation on Pumptrol Pressure Switches

          Product Line:
          IDSEN - Sensors

          Environment:
          9013F and 9013G

          Cause:
          Maintenance, adjustment, and troubleshooting

          Resolution:
          Data Bulletin 9013DB0701 is the source for maintenance and troubleshooting guidelines. Please reference the attached documentation
           

          Is the 9013F compatible with Skydrol?

          Issue:
          Is the 9013F compatible with Skydrol?

          Product Line:
          Pressure switches

          Environment:
          9013F

          Cause:
          Material comparability

          Resolution:
          It is not recommended for Skydrol.  Nitrile is the standard material used in diaphragm for the 9013F devices. The 9012G has an option to use ethylene propylene, form Q3, for the diaphragm.

          Note that 9012G switches are control devices and cannot support inductive loads directly, but require an interposing contactor.

          Is there a snubber or surge reducer for a 9012G type pressure switch?

          The 9049A26S is a surge suppressor for use in applications with oil, coolants, and hydraulic fluids.  This snubber cannot be used on air or water applications.  There is no suppressor for these types of applications; it will be necessary to move the switch physically away from the pump.





           

          What is the material of the cover for a 9013GHG2 made of?

          Product Line:
          Pumptrol pressure switches, Class 9013

          Resolution:
          Noryl SE-1X is used on 9013G devices for the cover, and on 9013F products with 3R rating.


          CTA-ID : 2010510

          Will SoMachine 4.1 be compatible with Windows 8 or Windows 8.1?

          SoMachine 4.1 is not compatible with Windows 8 or Windows 8.1 as a base install, but will be compatible with Service Pack 1. Service Pack 1 will be released in January 2015.

          Can the Magelis HMIGTU series be configured with SoMachine v4.1?

          Currently, the new HMIGTU terminals cannot be configured with SoMachine v4.1. The new terminals Magelis GTU will be available in future SoMachine software with Vijeo Designer V6.2 SP3 scheduled Q2 2015.

          What is the part number of the fixed Front Connection snap-in nuts for the Compact NS100 to 630 circuit-breakers.?

          The part number of a set of 12 fixed front connection snap-in nuts is:

          29234 for Compact NS100.
          30554 for Compact NS160... 250.

          These parts are not available for Compact NS400 to 630.

          eXL Hoist Change - 20154

          Issue:
          Is there any difference between the older generation and newer generation of the eXL Hoist controllers?

          Product Line:
          Wireless Joysticks - GIC Product

          Environment:
          US Product

          Cause:
          Product Characteristics

          Resolution:
          The eXL Hoist system was changed in late 2015 to incorporate a better battery than the older design.  Besides this change, there is no functional difference between the units.

          What are the part numbers to make up a 4 gang switch with LED for the Iconic range?

          The part numbers to make up a 4 gang switch with LED for the Iconic range are - 3044G , 40ML & 3044C

          For further information visit links below:-
          https://www.clipsal.com/Trade/search-results?q=3044G
          https://www.clipsal.com/Trade/search-results?q=40ML
          https://www.clipsal.com/Trade/search-results?q=3044C
          User-added image

          What is the temperature rating of a 9013FSG2J20? Will it work in hot water at 140 F?

           
          Issue: 
          What is the temperature rating of a 9013FSG2J20? Will it  work in hot water at 140 F?

          Product Line:
          Pressure Switches

          Environment:
          Pressure switches commercialized in the US

          Cause:
          What is the temperature rating of a 9013FSG2J20? Will it  work in hot water at 140 F?
           
          Resolution:
          The Media temperature for all 9013 F & G switches is minimum -30C (-22F) and maximum 125C (257F).

          The ambient temperature is a minimum of -30C (-22F) and a maximum of 70C (158F).

          Is the pressure relief valve, Form X, of a 9013GHG2X field replaceable ?

          Product Line:
          9013 pressure switches

          Resolution:
          Yes, the valve can be replaced, 9049A12, on 9013G switches that were delivered with Form X. However, this is not a field retrofit for products that were not delivered with the Form X.


          CTA-ID : 850

          What is the ZC4CC reference? How to order?

          ZC4CC is not a commercial reference, but the marking on the contact ZC4CC2, sold in spare parts for the obsolete XR2PA* safety screw limit switch for mechanical press. See attached picture. ZC4CC2 is still available to order in 2015. It is a slow break contact type.

          Preventa XY2C_Old XY2CB10/20/30 rope pull switch; limit switch XC1AC1269 in spare parts

          Please find attached the contacts description in the XY2CB rope pull switches for simple stop, precising in which products the XC1AC1269 limit switch with reset button is used. XC1AC1269 special switch for XY2CB unit is still available to order in 2015.

          What is the part number for Iconic foxtel TV outlet?

          The part numbers for Iconic Foxtel TV outlet are 3041G + 3041C-** + 40PFM-TN

          3041G Clipsal Iconic - Switch-Grid, Vertical/Horizontal Mount, 1 Gang

          3041C-WY Clipsal Iconic - Skin Switch Plate Cover, Vertical/Horizontal Mount, 1 Gang

          Clipsal Iconic - TV Antenna Socket, 75 Ohm, F-Type

          For further information see:https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041G:https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041C-WYhttps://www.clipsal.com/Trade/search-results?q=40PFM
           

          M580 SD memory card format procedure

          M580 CPU SD memory card format procedure
          1. Connect to M580 and make sure the Unity project is “Equal”, “Run” and “Built”
          2. Stop the PLC
          3. Open SD card door and make sure LED is ON
          4. Open the “Animation Table” Window
          5. Add system word %SW93.0 and %SW93.1
          6. Turn on the “Modification” button
          7. Enter value “1” for %SW93.0
          8. (This will start the format of the SD card then that value will change back to “0” and the value of %SW93.1 will go from “0” to “1” to indicate the format has completed successfully), (Formatting a standard SD card takes about 30-50 seconds)
          9. When completed enter value of “0” for both %SW93.0 and %SW93.1
          10. Start PLC

          What are the Commercial and Government Entity (CAGE) codes for Schneider Electric (Canada only)?


          Issue
          What are the Commercial and Government Entity (CAGE) codes for Schneider Electric (Canada only)?

          Product Line
          CAGE codes

          Environment
          CAGE code is a unique identifier

          Cause
          CAGE codes provide a standardized method of identifying a given facility at a specific location.

          Resolution
          The CAGE codes for Schneider Electric/Square D are listed below:

          CAGE Code Company Address
          L0154 POWER MEASUREMENT LTD 2195 KEATING CROSS RD SAANICHTON, BC V8M 2A5

          What is the replacement for ACW8 Pressure Switch?

          The replacement for ACW8 Pressure Switch is 9012GAW6

          9012GAW5
          pressure switch 9012G - adjustable scale - 2 thresholds - 3.0 to 150 psig
          For further information go to:
          https://www.tesensors.com/global/en/product/pressure-level-control/nema-pressure-switches/?el_typ=product&cat_id=BU_AUT_61350_L3&conf=basket&prd_id=9012GAW5&scp_id=Z000&lc=en|9012GAW5

          Is there a HMI touchsceen with Wi-Fi capabilities

          Yes.  The Magelis HMIGTU 12" Display includes Wireless Lan capabilities.
          The Innovative Access Point embedded in HMI to provide easy, robust and secure wireless connection to Industrial architecture.
          This Display is available only with the last version of Magelis GTU Open Box PV02/SV2.0 or later AND VijeoDesigner software version V6.2 SP3.
          This unit will be available in June 2015.  The part number is HMIDT643.






           

          Is Iconic intermediate mechanism available assembled on a switch plate?

          Unfortunately, the Iconic intermediate mechanism is not available assembled on a plate. It can put together using below part numbers;
          40MIL  - Clipsal Iconic Intermediate Switch Mechanism, 250V, 10A, LED.
          +
          3041G - Clipsal Iconic - Switch-Grid, Vertical/Horizontal Mount, 1 Gang
          +
          3041C - Clipsal Iconic - Skin Switch Plate Cover, Vertical/Horizontal Mount, 1 Gang
          For further information, please visit the below links:
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=40MIL
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041G
          https://www.clipsal.com/Trade/search-results?q=3041C


          What part numbers are needed to put together an Iconic 1 gang electronic Pushbutton switch plate (Vivid white)?

          Below are the part numbers needed to put together an Iconic 1 gang electronic Pushbutton switch plate :

          3041G - Clipsal Iconic - Switch Grid, Vertical/Horizontal Mount, 1 Gang
          For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041G

          +

          3041C-VW -Clipsal Iconic - Skin Switch Plate Cover, Vertical/Horizontal Mount, 1 Gang, Vivid White
          For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041C-VW​

          +
          41E350PBES2SM-VW -Clipsal Iconic - Electronic Switch Mechanism, Push Button with ControlLink (without bluetooth) 2-wire, 350W
          For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=41E350PBES2SM

          PM800 Series meter display showing reading of Current & Wattage only in number like 1A 2A, how to display with decimal point like 1.1A, 1.2A.

          To adjust the scale factor of PM800, the procedure would be as follows: 
          Step 1) Write the value 9020 to register 8000 to enter the setup mode. 
          Step 2) Write the desired scale factor value to the appropriate register. The scale factor would be in the range of #3209 to 3215, there is a range each type of scale factor.  Refer the attached extract of PM800 register list. e.g. if you want to change the 3 phase ammeter so that you can read up to 1 decimal.  You have to write -1 as value for the register 3209  e.g. if you want to change the power so that you can read it as mega watt.  You have to write 3 as value for the register 3214  Repeating this step for each subsequent scale factor change can change multiple scale factors. 
          Step 3) Write the value 1 to register 8001 to save the changes made in Step 2. 
          Step 4) Write the value 9021 to register 8000 to exit the setup mode.  The power meter will reset. The power values will now be displayed on the Display of power meter with the new scale. 

          ION_Data Maintenance Job Fails

          Goals and Symptoms


          Summary

          The scheduled maintenance job for the ION_Data database fails due to insufficient space on the C drive.

          Symptoms

          The following information appears in the Task History of the Maintenance job for the ION_Data database:

            • Step 1

              Executed as user: NT AUTHORITY\SYSTEM. Insufficient space is available on C: drive to execute the requested task. The system database tempdb must be able to grow to 1085.60 MB to complete the requested task.

               

              Job Outcome

              The job failed.    The Job was invoked by Schedule 11 (Schedule for [ION_Data] - MAINTENANCE - Job).    The last step to run was step 4 (Step 4 - Email On Task Failure).

          Facts and Changes

          KeywordsION_Data

          Maintenance

          Database Manager

          Causes and Fixes

          Cause

          There is insufficient disk space on the C drive.  If the available space is less than 1.1GB, the Maintenance schedule will not work.

          Resolution

          Free up space on the C drive to let the system database (tempdb) to grow to 1.1 GB.

          Alternatively, move tempdb to a location where there is sufficient space.  See KB article 10156 for instructions on how to do this.

           

          Original article#10873


          Legacy KB System (APS) Data: RESL182947 V1.0, Originally authored by DaMi on 03/20/2007, Last Edited by DaMi on 03/20/2007
          Related ranges: ION Enterprise

          How Does Tenant Metering Software Commercial Edition (TMSCE) Calculate 15, 30, or 60 Minute Rolling Demand?

          If the data is collected on a 15 minute interval, there is no difference between rolling demand and present demand. Data that is collected on a 5 minute interval is the average of the current interval and the previous two. For example, if the data is measure at 2:00, 2:05, 2:10, 2:15, 2:20, 2:25, and 2:30, the rolling demand for 2:20 would be the average of the readings taken at 2:10, 2:15, and 2:20.
          With 15 minute interval data, the 30 minute rolling demand is calculated by averaging the previous demand interval with the current one. For example, data is taken at 2:00, 2:15, 2:30, 2:45, and 3:00. The 30 minute rolling demand for 2:45 is the average of the demand readings at 2:30 and 2:45.

          With 15 minute interval data, the 60 minute rolling demand is calculated by averating the current demand interval with the previous three. For example, data is taken at 2:00, 2:15, 2:30, 2:45, 3:00, 3:15, 3:30, and 3:45. The 60 minute rolling demand for 3:15 is the average of the demand readings at 2:30, 2:45, 3:00, and 3:15.


          Legacy KB System (APS) Data: RESL198518 V1.0, Originally authored by AnVa on 05/16/2009, Last Edited by AnVa on 05/16/2009
          Related ranges: Tenant Metering Software

          How is MTBF (Mean Time Between Failures) Calculated?

          Goals and Symptoms:

          How is MTBF (Mean Time Between Failures) Calculated?

          Causes and Fixes:

          How is MTBF (Mean Time Between Failures) Calculated?

          1. Computed following RDF2000 Reliability model (UTE C 80-810 standard) - EQUIPMENT ambient temperature at 30deg C (86deg F), 60deg C (140deg F) and 85deg C (185deg F)
          • 2. Continuous operation profile: 100% operation rate per year (365d / year, 24h / day) - 12 power on/off per year (1 per month) - No stocking days
          • 3. Intermittent operation profile: 46% operation rate per year (335d / year 12h /day) - 335 power on/off per year (1 per operating day) 30 stocking days
          • 4. MTBF are given in hours

          Is the Concept programming software still available for sale?

          The Concept software is no longer on the active sale list. As of May 31, 2015, the Concept software can no longer be ordered through your local distributor. The software now needs to be ordered through the Service Sales group. Simply send an email request to the Service Sales group for pricing. The Service Sales group can be reached at "service.sales@schneider-electric.com".


          R-82117


          Legacy KB System (APS) Data: RESL211134 V1.0, Originally authored by DaSo on 04/05/2013, Last Edited by DaSo on 04/05/2013
          Related ranges: Concept

          Is the ProWORX 32 programming software still available for sale?

          The ProWORX 32 software is no longer on the active sale list.

          As of May 31, 2015, the ProWORX 32 software can no longer be ordered through new product sales.
          The software now needs to be ordered through the Service Sales group.
          The Service Sales group can be reached at "service.sales@schneider-electric.com".  Send an email with your request. 

          The part number for a full function single install is 372SPU78001PDEV.

          Can a 9012GAR5 be used on water systems?

          Issue:     
          Can a 9012GAR5  be used on water systems?

          Product Line:
          Pressure Switches

          Environment:
          9012 Pressure Switches

          Resolution:
          Yes, all components are compatible with water systems. However, salt water may attack standard flange material and may work best with 9013F Form Q. It is important to note that these switches are control rated devices. An interposing starter, or contactor must be used for switching a pump motor . Low level signals to PLCs or computers requires the use of an interposing low level switching relay.


           

          I have email about billing my credit card for my Wiser account? I want to cancel my account.

          Issue:
          I have email about billing my credit card for my Wiser account?  I want to cancel my account.

          Product Line:
          Wiser Home Management System
          Wiser Generation 1.0 System 2013 to 2015, centered on the Wiser Coordinator EER21200 and the portal https://www.wiserenergy.com

          Environment:
          United States and Canada

          Cause:
          The website for the Wiser System, Generation 1.0,  www.wiserenergy.com, is powered by security company Alarm.com.  Alarm.com setup the site with 2 plans of features, Basic and Premium.  The Premium plan costs %5.99 per month billed to a credit card.   Customer may not have realized that his account was setup as Premium.

          From 2013 to 2015, KB Home was one of the major Wiser Customers.  With KB Home, there was a plan in place to allow Premium plan for free for 1 year.  KB Home customers may have registered as Premium accounts.  After 1 year, those customers get notified that their account billing is beginning.

          Resolution:
          Explain the differences between Premium and Basic plans. See attachment.   Login to the Alarm.com Dealer Portal for Wiser.  Convert the account to Basic or terminate the customer.  
           

          What solution does Schneider Electric offer for arc-flash incident energy mitigation?

          Issue:
          Arc Flash mitigation

          Product Line:
          Masterpact and Powerpact P and R

          Resolution:
          Prior to October 2015, the AMS system was used.  Refer to FAQ FA176050 for more information on this option.
          Since October 2015, the Energy Reduction Maintenance Setting (ERMS) System has been the preferred method of reducing arc-flash incident energy.

          The ERMS switch can be turned “ON” to reduce circuit breaker tripping time. This sets the instantaneous pickup to a pre-programmed value.
          Default if not programmed = 2 x In. 
          Basic components are:
          1. A Masterpact or Powerpact circuit breaker with a Micrologic P or H trip unit with a blue label on the upper right corner with the letters ERMS
          2. An I/O Module (Input/Output Programmable Module) LV434063
          3. A switch, ULP cable, power supply
          See attached for more information, esp. page 5 for instructions and page 19 for the wiring diagram.

           

          Osisense XM_XMPC06C2941S701 specifications and how to order in 2015

          1) The XMPC06C2941S701 power switch is the "standard" XMPC06C2941 (available under logistic ref. XMPC06C2941AB in 2015, requesting to provide the fluid entries A, B, C, D definition) supplied with S701 specification.

          2) S701 specifications meaning
          • 1/2 gas fluid connection drilling in A (see attached file for fluid entries designation)
          • 1/4 gas fluid connection drilling in C
          3) How to order the XMPC06C2941S701 reference in 2015 : it has to be ordered under the following logistic reference XMPC06C2941S701AB (internal Schneider rule). Logistic situation : available, in stock in IDC Evreux France.
          Show More