Acti9 Residual current circuit breaker (RCCB) iID, 2P, 40A, A type, 30mA

Home ProductsCircuit ProtectionActi9Residual current circuit breaker (RCCB)

Acti9 Residual current circuit breaker (RCCB) iID, 2P, 40A, A type, 30mA

Item Number: A9R51240

Datasheet

Product Dimensions

Width icon

Width36 mm

Height icon

Height91 mm

Depth icon

Depth73.5 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

iID

Range

Acti9

Product or component type

residual current circuit breaker (RCCB)

Warranty

18 months

Physical

[in] rated current

40 A

[ue] rated operational voltage

220...240 V AC 50/60 Hz

Control type

toggle

Mounting mode

clip-on

Mounting support

DIN rail

Height

91 mm

Width

36 mm

Depth

73.5 mm

Net weight

0.21 kg

Mechanical durability

20000 cycles

Electrical durability

AC-1: 15000 cycles

Connections - terminals

  • single terminal top or bottom 1-35 mm² rigid
  • single terminal top or bottom 1-25 mm² flexible
  • single terminal top or bottom 1-25 mm² flexible with ferrule

Wire stripping length

14 mm for top or bottom connection

Standards

EN/IEC 61008-1

Ip degree of protection

  • IP20 conforming to IEC 60529
  • IP40 (modular enclosure) conforming to IEC 60529

Ambient air temperature for operation

-25...60 °C

Ambient air temperature for storage

-40...85 °C

Mercury free

Yes

Rohs exemption information

Yes

Environmental disclosure

ENVPEP1409014_V3-EN

Eu rohs directive

Compliant with Exemptions

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant By Exemption

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Others

Package 2 bare product quantity

54

Package 3 bare product quantity

432

Average percentage of recycled plastic content

0 %

Legacy weee scope

In

Package 1 bare product quantity

1

At least in Europe

Warranty duration(in months) bmecat

18

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Product name

Acti9 iID

Device short name

iID

Poles description

2P

Neutral position

left

Network type

AC

Earth-leakage sensitivity

30 mA

Earth-leakage protection time delay

instantaneous

Earth-leakage protection class

type A

Device location in system

outgoer

Network frequency

50/60 Hz

Residual current tripping technology

voltage independent

Rated breaking and making capacity

  • Idm 1500 A
  • Im 1500 A

Rated conditional short-circuit current

10 kA

[ui] rated insulation voltage

500 V AC 50/60 Hz

[uimp] rated impulse withstand voltage

6 kV

Surge current

250 A

Contact position indicator

yes

Comb busbar and distribution block compatibility

top or bottom: tooth

Connection pitch

18 mm between phase and neutral

9 mm pitches

4

Total power losses

7.6 W

Power losses per pole

3.8 W

Locking options description

padlocking device

Tightening torque

3.5...3.5 N.m top or bottom

Compatibility code

iID

Pollution degree

3

Electromagnetic compatibility

8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

8.500 cm

Package 1 width

4.000 cm

Package 1 length

9.600 cm

Package 1 weight

218.000 g

Unit type of package 2

S03

Number of units in package 2

54

Package 2 height

30.000 cm

Package 2 width

30.000 cm

Package 2 length

40.000 cm

Package 2 weight

12.180 kg

Green premium status for reporting

Green Premium product

Total lifecycle carbon footprint

43 kg CO2 eq.

Carbon footprint of the manufacturing phase [a1 to a3]

1.8284703892548855

Carbon footprint of the manufacturing phase [a1 to a3]

2 kg CO2 eq.

Carbon footprint of the distribution phase [a4]

0.04649715944710452

Carbon footprint of the distribution phase [a4]

0 kg CO2 eq.

Carbon footprint of the installation phase [a5]

0.020625136679757818

Carbon footprint of the installation phase [a5]

0 kg CO2 eq.

Carbon footprint of the use phase [b2, b3, b4, b6]

40.930942165455185

Carbon footprint of the use phase [b2, b3, b4, b6]

41 kg CO2 eq.

Sustainable packaging

No

Carbon footprint of the end-of-life phase [c1 to c4]

0.5371542284502423

Carbon footprint of the end-of-life phase [c1 to c4]

0.5 kg CO2 eq.

Energy efficiency optimized

False

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Total lifecycle carbon footprint

43.36368907928718

Average percentage of recycled metal content

0 %

Packaging made with recycled cardboard

No

Packaging without single use plastic

Yes

Scip number

42d9fa7e-1604-4ebd-8742-78b281843dbb

End of life manual availability

N/A

Take-back

No

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Warranty (in months)

18
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Environmental Disclosure

  • Operating Manuals

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.