Browse all
Browse all

C-Bus DALI-2 Gateway SpaceLogic, 6DIN

C-Bus DALI-2 Gateway SpaceLogic, 6DIN

Item Number: 5502CDGP230

Datasheet

Product Dimensions

Width icon

Width108 mm

Height icon

Height93 mm

Depth icon

Depth63 mm

Specifications

Design

Range SpaceLogic C-Bus
Product brand Schneider Electric
Product or component type gateway
Device application light control

Physical

Communication port protocol
  • C-Bus
  • DALI-2
[in] rated current 0.23 A
Communication network type
  • C-Bus
  • DALI
Connector type 2 RJ45
Connections - terminals screw terminals
Mounting support DIN rail
Width 108 mm
Height 93 mm
Depth 63 mm
Ambient air temperature for operation -5...45 °C
Ambient air temperature for storage -20...80 °C
Product certifications
  • RCM
  • CE
Environmental disclosure ENVPEP2104025_V1
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant By Exemption

Others

Legacy weee scope In
Package 1 bare product quantity 1
Average percentage of recycled plastic content 0 %
Outside of Europe
Warranty duration(in months) bmecat 18
Weee label N/A
Weee applicability Finished product
Product name DALI-2 gateway
Module configuration programmed with C-Bus software
Software name SpaceLogic C-Bus Commission
Input voltage 110...240 V AC at 50/60 Hz
Supply maximum power 13 W
Input current 0.25 A
Total number of 18 mm modules 6
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 9.8 cm
Package 1 width 11.1 cm
Package 1 length 15.6 cm
Package 1 weight 0.359 kg
Unit type of package 2 CAR
Number of units in package 2 10
Package 2 height 30 cm
Package 2 width 30 cm
Package 2 length 40 cm
Package 2 weight 4.15 kg
Total lifecycle carbon footprint 2 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 2.2442994897959188
Carbon footprint of the manufacturing phase [a1 to a3] 2 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.00004631924234693878
Carbon footprint of the distribution phase [a4] 0 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.00000660734005102041
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 98.39245192307692
Carbon footprint of the use phase [b2, b3, b4, b6] 98 kg CO2 eq.
Sustainable packaging No
Carbon footprint of the end-of-life phase [c1 to c4] 0.00023625313775510202
Carbon footprint of the end-of-life phase [c1 to c4] 0 kg CO2 eq.
Pvc free Yes
Halogen-free status Halogen free product
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 2.334698083394603
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic No
Halogen-free status Halogen free product
Pvc free Yes
End of life manual availability ENVEOLI2104025EN
Take-back No
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • Product Brochures

  • Other technical guide

  • Installation Instruction

  • Environmental Disclosure

  • End of Life Manual

  • Quick Start Guide

  • Operating Manuals

  • Declaration of Conformity

  • Certificates (MSDS)

  • Declaration of Conformity (Sustainability)

  • Software - Release

Important: Some software files may need a mySchneider or Club login to download.

Frequently Asked Questions

Article to be archived

Hide Show

For the 5502CDGP230, the C-Bus Clock can be enabled or disabled via the front panel, by pressing and holding down the MANUAL button on Line A, and short pressing the ID button on Line B.

 

DALI Interface Buttons

 

Which project types can be imported into C-Bus Commission?

Hide Show

 As of SpaceLogic C-Bus Commission v2.15.0, projects of file types: *.c2z, *.cbz and *.xml can be imported as a C-Bus Project 

What different scans can be performed on the DALI Line in C-Bus Commission?

Hide Show

As of C-Bus Commission v2.15.0, the available scans for a DALI are:

1. DALI Scan

2. DALI Device Type Scan

3. Read DALI Gateway

4. Discover Faults

 

Software Interface

 

Note: A Scan can also be done by pressing the INSTALL button of each line on the front of the unit

What is the purpose of the Read DALI Gateway scan?

Hide Show

A Read DALI Gateway scan helps to rebuild a project from a live/existing & operational C-Bus DALI-2 Gateway that has been previously configured.

 

The scan retrieves the information stored on the live gateway, including its own programming and programming all connected DALI Devices.

 

 D2G Interface  

Where can I find the latest version of C-Bus Commission?

Hide Show

Use the provided link to find and/or download the latest version of SpaceLogic C-bus Commission:

SpaceLogic C-Bus Commission

Where to download the SpaceLogic C-Bus Commission V2.2.0?

Hide Show
Where to download the SpaceLogic C-Bus Commission V2.2.0?
Release Date: 02/04/2024
Version: V2.2.0
Reference: C-Bus-Commission_V2.2.0
C-Gate: 3.3.0 (build 1825)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10.

What’s New 
• Dimmer conversion will add default channel name
When converting older LE dimmers DIMDN4 or DIMDN8 (L5504D2A or L5508D1A) to the new digital dimmers DIMDD4 (5504D2D) and DIMDD8 (5508D1D), the software will now automatically insert a default channel name per channel.

• Network Summary for a C-Bus Network
The C-Bus Network node will show the summary of network information and status including the C-Bus Current supplied and consumed values plus the network impedance value. This data is only taking the project devices into consideration (not the live network devices).

• View the in-built C-Bus power supply status of C-Bus Digital Dimmers on the live network
An icon has been added to the Status column in the Network Devices section of the C-Bus Devices workspace indicating whether the in-built C-Bus Power Supply for the new C-Bus Digital Dimmer (DIMDD4 and DIMDD8) is enabled or disabled.

Fixes
• Project conversion issues. The software will now show correctly when a project has truly failed to convert. Issue with projects in “Waiting” resolved.
• Multiple confirmation dialogues when delete a device in project.
• When transferring to a C-Bus Automation Controller and C-Bus Application Controller, updating a Tag Map name will create an Object if one does not exist, this can result in additional objects created in controller that were not defined in the Object List. Note, this release of SpaceLogic C-Bus Commission software is only compatible with the C-Bus Automation Controller and C-Bus Application Controller firmware version 1.16.0 (when using the Controller Sync function).
• Warn Before Off Enable Group in live network Digital Dimmer is blank and not auto created during a network scan.
• Network burden property of Digital Dimmers did not update the C-Bus summary data (not included in network calculator).

Known Issues
• A slight delay may be seen when switching views back and forth between the Measurement and Error applications where a large amount of data (150 items or more) exists.
• Clicking on the Main Menu repeatedly will result in a decrease in software performance. C-BUS COMMISSION RELEASE NOTES 2
• Switching projects 10 or more times will result in a decrease in software performance.
• Measurement application values presented from the live network may not appear truncated and rounded to reasonable decimal places.

Link to download the SpaceLogic C-Bus Commission V2.2.0
https://www.se.com/nz/en/download/document/C-Bus-Commission_V2.2.0/
or
https://www.se.com/au/en/product-range/2216-spacelogic-cbus-home-automation-system/?parent-subcategory-id=88010&filter=business-5-residential-and-small-business#software-and-firmware
 

Can the new Dali gateway 5502DCGP230 firmware be updated?

Hide Show

Yes installer can update the firmware of the device in the field

  1. without disconnecting any connections
  2. without removing the unit from the switchboard

A USB device port is provided on the front cover of the device as a power source.

Using Space logic C-Bus Commission software > Firmware update in Space logic

Front image of 5502DCGP230
 

DALI broadcasts messaging from the DALI gateway vs DALI broadcasts from a DALI Dual Power Supply via the override Push Buttons

Hide Show

The differential of the DALI broadcasts messaging from the DALI gateway via a C-Bus Group vs Sending broadcasts from a DALI Dual Power Supply via the Push Buttons on the front of the power supply.

  1. Sending broadcasts from the DALI gateway via a C-Bus Group.

  2. Sending broadcasts from a DALI Dual Power Supply via the Push Buttons on the front of the power supply.

They're different commands with the same outcome.

Sending broadcast from the DALI gateway via a C-Bus Group use ARC command i.e it come with a fade time before the ARC power level of 254(100%) and 0(Off)

 

capture1

 

Sending broadcast from a DALI Dual Power Supply via the Push Buttons on the front of the power supply is direct Max and Off

 

capture2

 

Where can I download the Visio and CAD for Dafligateway2 (5502CDGP230)

Hide Show
Please see attached Visio and CAD for Dafligateway2 (5502CDGP230)

Visio and CAD for Dafligateway 2 5502CDGP235
 

What device type does the C-BUS Dali2Gateway (5502CDGP230) support?

Hide Show

The C-BUS Dali2Gateway can currently support DT0, DT1, DT6.

1


 

What dali device type does the C-BUS Dali2Gateway (5502CDGP230) support?

Hide Show

The C-BUS Dali2Gateway F/W 1.8 can currently support DT0, DT1, DT6. It doe not yet support Tunable White and RGB/RGBW

1


 

How to Factory Reset daligateway2 (5502CDGP230)?

Hide Show
 

To factory reset the daligateway2. Simply press the SR button with pointy device i.e a paper clip

 

HOLD DOWN THE (SR) BUTTON FOR 10 SEC. LET GO THEN HOLD IT DOWN AGAIN FOR 2 SEC.

1

 

factory reset 5502cdgp230

 
 

How to Factory Reset daligateway2 (5502CDGP230) to original manufacturer settings

Hide Show

To factory reset the daligateway2. Simply press the SR button with pointy device i.e a paper clip for 10 Seconds. Release then a long press for more than 0.5 sec.

 

factory reset to original manufacturer

 

factory reset 5502cdgp230

How to properly select location and mounting of daligateway2 (5502CDGP230)

Hide Show

The C-Bus DALI-2 Gateway is designed to be installed in a distribution cabinet, mounted on a DIN rail (type DIN EN60715), in a horizontal position.

There should be adequate ventilation to prevent overheating of this unit, this can be achieved by using larger distribution boards as opposed to small domestic distribution boards.

C-Bus Cat-5e cables Should be adequately separated or segregated as defined in local wiring regulations.

Note: Use the heat load value of all the units in the cabinet to select a cabinet with correct ventilation. Ensure that the temperature around the unit is less than 45C.