Standard Series, Single Switch Socket Outlet, 250V,10A, Skirt Mount White Electric
Item Number: 16-WE
Datasheet
Specifications
Design
Range of product
Product or component type
Product brand
Surface finish
Sustainable offer status
Physical
Control type
Number of gangs
Pin number
Number of power socket outlets
Actuator
Fixing mode
Local signalling
Mounting position
[ue] rated operational voltage
[in] rated current
Depth
Length
Width
Fixing center
Standards
Reach regulation
Eu rohs directive
Rohs exemption information
China rohs regulation
Environmental disclosure
Circularity profile
Material
Material
Others
Commercial status history
Package 1 bare product quantity
Package 2 bare product quantity
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Documents & downloads
hide show-
All
-
Technical Data Catalogues
-
Environmental Disclosure
-
Specification Guide
Frequently Asked Questions
hide showIssue:
Connecting SoMove to the VFD using the Ethernet network connection.
Product Line:
ATV61
ATV71
ATV630
ATV930
ATV320
ATV340
ATV32
Environment:
Ethernet IP or Profinet option installed.
VW3A3316, VW3A3320, VW3A3627 VW3A3720
Cause:
Drive is not detected when attempting to connect.
Resolution:
See attachment for screenshots showing SoMove V2.9.4
STEP 1
Turn OFF your computers firewall before starting so you will have access to your Ethernet port.
STEP 2
Edit Connection on your computers ethernet port and setup IP address in the Altivar Drive using an HMI.
Computer or PC setup:
Example setting up your PCs IP address.
Search Ethernet settings
-Change adapter options
- Choose the Ethernet port you want to use.
-Choose Properties
-Make sure IPV4 and IPV6 are both checked.
-Double click on the IPV4 settings
-Select "Use the following IP address" and now enter in an IP address for your PCs ethernet port.
Note this IP address needs to match your Drives IP address up to the last octet.
Drives IP address= 10.172.86.1 (for the Drive) and your PC's IP address = 10.172.86.10 (your computer)
Subnet address= 255.255.255.0
-Choose ok
Drive Setup
Example set your Drives IP address using the remote HMI under the Ethernet settings in the programming.
Type=Fixed
IP address= 10.172.86.1 (for the Drive)
Subnet address= 255.255.255.0
-Power cycle your Drive after changing the IP address
STEP 3
Open up Somove 2.9.4 or newer and setup your "edit connection/scan" settings.
-Click on "edit connection/scan"
-Choose Modbus TCP double click
-Choose the advanced settings (small gear wheel icon).
-Choose More
-Choose Scan tab
-Now type in your Drives IP address example 10.172.86.1
-Choose Single Scan and enter 1
-Apply and OK
-Ok again
STEP 4
-Now Scan for the Device to see if your PC finds the Drive.
-double click on the picture of the drive to connect and load from the device.
NOTE: If your Drives ATV630 or ATV930 Firmware is version V3.3IE or above it will now include cyber security features and you will have to enter a password before connecting to the drive other Ethernet or Profinet. You can find this unique password on your HMI under the Communications menu, Embedded Ethernet configuration, and find SECE. SECE select OK on the HMI and then select WDPE and press ok. Your will now see your unique password example "iY^Nm9cV"
This password is temporary and will need to be changed and remembered.
The USERNAME: ADMIN (all caps)
The Password: iY^Nm9cV (for this example only)
Please read and understand before checking OK.
Somove is loading settings from the Drive to your Somove on your PC.
Your are now connected to the Drive when the bar across the top turn's orange.
Please be aware that you will be required to enter a password when you connect via Ethernet or Profinet if your Process Drive is version V3.3IE or higher so if you live in an area or work for a company that does not require or mandate having a password for Ethernet or Profinet for cyber security you can disable the feature if desired. Otherwise leave the feature active which can offer the best cyber security.
Done.
NOTE:
This example should work using.
-Ethernet TCP
-Ethernet IP
-Profinet
What is the process for ordering a Masterpact NW or NT circuit breaker?
Product Line:
Circuit Breakers
Resolution:
Masterpact circuit breakers cannot be ordered by catalog number. A Schneider distributor or sales office must enter the order via the online product selector in My Schneider, SE Advantage, or Quote to Cash.
Information they need includes the certification standard (UL, ANSI, IEC), fixed or drawout, ampacity, AIR required, trip unit functions or type, accessories, connectors, and other customer specifications.
The attached decoder will assist in breaking down a catalog number to its component parts. With knowledge of the breaker's construction it will be possible to use the Q2C or SE Advantage product selector to select, quote, and order the breaker. DO NOT try to build a catalog number using the decoder. A number generated using the decoder will be prone to error due to possibly selecting components and features which are mutually exclusive, and the number will have no value for quotation or ordering even if valid.
Required information for placing an order can be found on the attached RFQ (Request for Quote) or RFQ - DC for DC rated Masterpacts.
Why is the display blank on the trip unit?
Product Line:
Powerpact P frame, Powerpact R Frame, Masterpact NT, Masterpact NW
Resolution:
The LCD display on a Micrologic P or H trip unit will be blank unless the trip unit is energized. Energization requires one of the following sets of conditions:
- The trip unit is energized by an external 24 Vdc applied to terminals F1-F2 (F1 negative-F2 positive). See attachment for location of terminals.
- The trip unit is energized by an FFTK or HHTK test kit
- There is at least 100 V between two phases, AND the load reaches approximately 20% of the breaker's rated current.
- Note that the display will not power up with primary injection testing unless one of the conditions in bullet 1 above is met.
- Note that Ammeter trip units do not require external power and the display will come on with sufficient current flow alone.
ATV312 Short Circuit Current Ratings (SCCR) information.
Product Line:
Altivar 312
Environment:
All
Cause:
Short circuit protection for drives
Resolution:
Please see attached for information.
Can the ground fault pickup be disabled on a Micrologic 6.0A (ammeter), 6.0P (power), or 6.0H (harmonic) trip unit?
Product Line:
Micrologic, Masterpact, Powerpact
Resolution:
No. To eliminate ground fault protection, replace the trip unit with a 5.0 of the same type.
For ground fault alarm, replace the trip unit with a 5.0P or 5.0H trip unit and use an M2C (S64273) programmable contact module or I/O module(s) (LV434063).
Note: if ground needs to be temporarily disabled for primary injection testing, refer to FA98682.
Identify the parts break down of a 9001KYK116
Product Line:
30mm, 9001KY/SKY Control Stations
Environment:
Pushbuttons and Operator Inteface
Resolution:
9001KY1 - Enclosure
9001K15 - Emergency Break Glass Operator
9001KA1 - 1NO and 1NC Contact Block
9001KN799RP - Legend Plate (Special Marking)
Issue:
Which guard should be used with the 9001KR16 or 9001SKR16?
Product Line:
Push Buttons and Operator Interface
Environment:
9001K and 9001SK 30mm operators
Resolution:
The 9001K56YM or the 9001K56RM are suitable guards for this operator
Is the mushroom lens for a XB2BN or standard ZB2BW illuminated mushroom button replaceable?
Product Line:
Legacy Push Buttons
Environment:
Obsolete 22mm
Resolution:
Replacement mushroom lenses were as follows:
White | W40429264001 |
Green | W40429264003 |
Red | W40429264004 |
Amber | W40429264005 |
Blue | W40429264006 |
Clear | W40429264007 |
NOTE: Some of them are already obsolete
Identify the part number for a guard for a 22mm push-pull mushroom head operator.
Product Line:
Harmony 22mm, XB4, XB5, Push Buttons
Environment:
Push Buttons and Operator Interface
Resolution:
Catalog number ZBZ160* is a metal guard for 40mm mushroom head operator.
ZBZ1600 | Chrome Plated |
ZBZ1602 | Black |
ZBZ1604 | Red |
ZBZ1605 | Yellow |
ZBZ1606 | Blue |
|
A9D33620 = SI (Super Immunised)
A9D32620 = Type A (AC or pulsating DC)
Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
Type Si RCBO = With all the features of a Type A device, “Si” type Super Immunised earth leakage protection range has been specially developed to be used with loads or in environments causing disturbances. Examples are lightning or switching surges, harmonics generated by increasing number of loads and constant load leakage current from electronic ballasts, speed drives, computers, etc. The Si increases safety and allows improved continuity of supply.
Need to know the size of the conduit entry in the 9001BR enclosures?
Product Line:
Push Buttons and Operators Interface
Environment:
Class 9001 Type BR Control stations
Resolution:
1/2-14 NPT Pipe tap in bottom only.
ATV16 drive will not power up or display is blank.
Product line:
Altivar Machines, Altivar 16
Environment:
All
Cause:
External control circuits are shorting out internal power supply or Power board is bad.
Resolution:
Remove all of the control wires to see if the display comes back up. Check all supply voltages. There are no replacement parts available. They will need to replace it with a new drive.
Issue:
ATV16 VFD replacement.
Product Line:
ATV16 Altivar 16
Environment:
All models
Cause:
Seeking replacement VFD for the obsolete ATV16.
Resolution:
Recommend the ATV320 product line.
Power wires installation for AC drives
Product Line:
Altivar drives
Environment:
All
Cause:
Installation
Resolution:
Good wiring practice requires the separation of control wiring from power wiring. Power wiring to the motor must have the maximum possible separation from all other power wiring, whether from the same drive controller or other drive controllers. Do not run power and control wiring, or multiple power wiring, in the same conduit. This separation reduces the possibility of coupling electrical transients from power circuits into control circuits or from motor power wiring into other power circuits.
Use of special shielded cables does not reduce or eliminate the need for cable separation.
Please refer to the installation documents for more information.
Calculation of kVA capacity for a Single or Three Phase Transformer, based on Winding Voltage and Amperage information.
Low Voltage (LV) Transformers
Learn more about DOE 2016 Energy Efficient Transformers by Schneider Electric
Applies to all Single and Three Phase Transformers.
kVA sizing must often be calculated from Primary or Secondary Winding Voltage and Amperage information.
This Frequently Asked Question offers three different methods for finding the needed information:
1. This link on the Schneider Electric Website is a Transformer Data Calculator:
https://tools.se.app/transformerdata/index.html?language=en&country=usa#/transformer-data
There are also the following methods for calculating or finding the Required Capacity kVA Rating or Amperage Capacity for Single and Three Phase Transformers:
2. To determine kVA you must have at least two pieces of information:
- the load line-to-line voltage (V)
- the maximum load phase current (I)
Single Phase Transformers: kVA = (V * I) /1000
Three Phase Transformers: kVA = (V * I * 1.732) / 1000
where 1.732 is the simple numerical value for the square root of 3 (1.7320508...)
Then round up to the next standard 3ph kVA rating as found in Section 14 of SquareD/Schneider Electric Catalog, Digest 178 .
Single Phase Transformer Example: V = 240, I = 175; Therefore: kVA = (240 x 175) / 1000 = 42 kVA
This calculates to 42 kVA, thus we round up to a standard Single Phase size 50kVA. From the Digest, an EE50S3H will satisfactorily serve this load.
Three Phase Transformer Example: V = 208, I = 175; Therefore: kVA = (208 x 175 x 1.732) / 1000 = 63.05kVA
This calculates to 63+ kVA, thus we round up to a standard Three Phase size 75kVA. From the Digest, an EXN75T3H will satisfactorily serve this load.
Note: This is a sample kVA calculation and does not take into account possible special load requirements, such as found with motors or some medical equipment, or other specialty applications.
Amperage provided for a given KVA can be determined by similar techniques:
Single Phase Example: Using a 50 KVA Single Phase Transformer as a starting point. 50KVA is equal to 50,000 VA. (K= 1,000) The full value in VA, 50,000 is then divided by the Voltage 240V = 208 Amperes. This is a "Two Step Division", technique: VA / Voltage = Amperage.
Three Phase Example: Using a 75 KVA Three Phase Transformer as a starting point. 75 KVA is equal to 75,000 VA. (K= 1,000) The full value in VA, 75,000 divided by 1.732 = 43,302, which is then divided by the Voltage 208V = 208.2 Amperes. This is a "Three Step Division", technique: VA / 1.732 / Voltage = Amperage.
3. As an alternative to these calculations, you may prefer to use the charts below. Standard KVA sizes are shown on the left margin, Standard Line-to-Line Voltages are shown along the top margin.
Chart Example: Using the numbers from the earlier Three Phase Transformer Example V=208, I=175. Use the chart titled "Three Phase Low Voltage Dry Type Transformers". Following the 208V top margin entry, and reading down vertically, it is seen that the first entry in that 208V vertical column that will cover 175A, and then some, is 208A, which indicates a 75 KVA Transformer, shown in the next over vertical column to the left.
See pages 3 & 4 of document 7400HO9501 "Looking for Low Voltage Transformer Solutions" for more information and conversion tables.
ATV16 obsolescence
Product line:
ATV16, Altivar 16
Environment:
All models.
Cause:
Determine age of unit, product obsolescence
Resolution:
The ATV16 became obsolete in 1996. The current replacement is the ATV12 or ATV320, depending on the application. There are some differences that should be reviewed by the customer such as wiring, dimensions, and ratings.
Installation of DC choke on the D version of the ATV61HD90N4D.
Product Line:
Altivar 61, ATV61
Environment:
ATV61HD90N4D
Cause:
The AV61HD90N4D was ordered which ships without the DC choke.
Resolution:
The DC choke for this part is not available for sale. Recommended solution is to add a 5% input line reactor, separately mounted.
Issue:
Needs the part numbers of the measuring board for the ATV61HC16N4 and ATV71HC13N4 drives
Product Line:
ATV61 and ATV71
Environment:
All
Cause:
Failed measuring board component within the drive.
Resolution:
The part number for the measuring board is VX5A71HC13N4 or VX5A71HC13N4F (For Fuji parts)
When a replacement Measurement board is needed, the serial number of the VFD needs to be verified.
If the 8th digit of the Serial number is a "2" as shown below than the replacement part number must have an "F" suffix.
See Attachment
What is the replacement lens cap for ZB2BW extended head push button?
Product Line:
Harmony Pushbuttons
Environment:
All Products
Cause:
Product selection
Resolution:
The ZB2 product line is discontinued. The replacement heads are no longer available
ZB2BW931 - White
ZB2BW933 - Green
ZB2BW934 - Red
ZB2BW935 - Ambler
ZB2BW936 - Blue
ZB2BW937 - Clear
Trying to install an option card on a ATV61 and ATV71 drive.
Product Line:
Altivar ATV61 and ATV71 drives
Environment:
All
Cause:
N/A
Resolution:
Remove the front display cover by pushing down on the two tabs on the top of the drive.
Once the front cover has been removed you can now install your serial communications card or extended IO card.
Once the Option card has been installed you can not reinstall the front cover by pushing down on the cover until you hear it click into place.
Issue:
Where can I download the EDS files for the Ethernet IP card?
Product Line:
ATV61, ATV71, ATV32, ATV Process
Environment:
All
Resolution:
Use this link to access the Global website where EDS files are available for download. Be sure to download the EDS file that matches your Drive and Product Version.
https://www.schneider-electric.us/en/download/search/?docTypeGroup=3587139-Software%2FFirmware&docType=1555901-EDS+Files
You will need to find out your drive's product version to choose the correct EDS file.
Example: In the ATV61 or ATV71; go to menu 1.11 in the drives menu enter
find the product Vxxxxxxxxx
This product version will need to be the version of the EDS file you download for that specific drive.
Issue:
Break down of ETA status word 3201 on the ATV61/ATV71 drives
Product Line:
Alitvar ATV61 and ATV71
Environment:
With Profibus option card
Cause:
Needs to know the bit breakdown for the ETA status word.
Resolution:
ETA status word for Word 3201
bit 0= Reserved
bit 1= Ready
bit 2= Running
bit 3= Fault
bit 4= Power section line supply present
bit 5= Reserved
bit 6= Reserved
bit 7= Alarm
bit 8= Reserved
bit 9= Command or Ref via network
bit 10= Referenced reached
bit 11= Reference outside of limit
bit 12= Reserved
bit 13= Reserved
bit 14= Stop via Keypad stop button
bit 15= Direction of motor 1=reverse 0=forward.
GV* Starter for 50/60hz application
Product Line:
Motor Starters and Protectors
Environment:
PowerPact™ Manual Starters
Resolution:
Yes, these starters are rated for 50/60 hertz.
This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.
Issue:
ATV61HC16N4 and ATV71HC13N4 spare parts manual.
Product line:
Altivar ATV61HC16N4 and ATV71HC13N4
Environment:
ATV61HC16N4 and ATV71HC13N4
Cause:
Someone needs a copy of the services manual for the ATV61HC16N4 and the ATV71HC13N4 drives.
Resolution:
Instruction bulletin 30072-452-78 is attached.
Setup VW3A3316 on ATV61/71 using assemblies 21 and 71.
Product Line:
Altivar ATV61 and ATV71 with VW3A3316 option card
Environment:
All
Cause:
Basic set up assistance on using the Ethernet IP VW3A3316 card on the ATV61 or ATV71 drive.
Resolution:
First, make sure that the Ethernet scanner module is set up for assemblies 21 and 71
Assembly 21= (output table) 2 words (4 bytes)
Assembly 71= (Input table) 2 words (4 bytes)
Drive program has to be as follows ( there are no exceptions when using these assemblies ):
Menu 1.6
Ref 1 channel = com card
Profile = Separate
CMD switching = C312
CMD channel 1 = com card
CMD channel 2 = terminal mode
Ref 2 switching = C313
Ref 2 channel 2 = AI1 or AI2 (do not leave this blank)
Commands to start the drive will be bits 0, 5 and 6 or HEX 0061 or DEC 97
Speed command is in RPMs and is the 2nd word in the output table.
If you are after a replacement electronic switch for a 5012S164/4L-WE then order the standard item “B5034MNLPCB-WE” which contains a PCB Assy plus the Rear Cover.
If you are after an equivalent to a 5012S164/4L-WE the closest we have can be achieved by ordering 1 x “B12/30/6-WE” + 3 x “5031NMML” + 9 x “5031NMS”
If just for replacement then you could get B503xNL and remove the Metal Plate and just use the gang switch to replace the old unit.
B5031NL, B5032NL, B5034NL
DALI mapping
5080CTC Colour V2/3 touch screen controlling dalicontrol
If having socket error when enabling Dali Mapping
Go into window services and stop Dalibuilding scheduler
This is used to avoid the inrush currents of certain loads, particularly lighting.
This solution involves a low leakage current traveling through the electronics which generates residual voltage at the contact terminals, even when open. This can cause problems when very low loads (small relays, LEDs, etc.) are operated, as the receiver may be "held on" by this spurious voltage.
Note:
For this type of application (low load), a conventional electromechanical programmable time switch should be used.
Over 7-10 years the battery requires replacing else if there is a power failure you’re risking losing time and all programming on the unit.
The replacement battery is CR2477N
For more information see:https://www.clipsal.com/products/detail?CatNo=C2016/2&tab-document-1=0&itemno=C2016/2-WE
Yes, the part number for end plugs is Clipsal 900/25/16P.
Please go to the website via the following links below and check under the Documentation Tab for more information.
Australia - https://www.clipsal.com/products/detail?CatNo=900/25/16P&itemno=900/25/16P-WE&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=900/25/16P&itemno=900/25/16P-WE&tab-document-1=0
Change the carrier switching frequency in an ATV66 drive
Product Line:
Altivar ATV66
Environment:
All
Cause:
Needs to change the switching frequency because of motor noise.
Resolution:
The only way to change carrier frequency is to go from CT or VT to VTLN or NOLD in menu 7.13.
There is no separate parameter available for switching frequency adjustment.
Refer to the ATV66 user manual VD0C06S305C page 61.
CTA-ID : 2018068
What is part number for an EMC filter for the Altivar 12 drives?
Product Line:
Altivar 12, ATV12, ATV11
Environment:
ATV12H018F1
ATV12H037F1
ATV12H018M2
ATV12H037M2
ATV12H055M2
ATV12H075M2
ATV12P037F1
ATV12P037M2
ATV12P055M2
ATV12P075M2
Cause:
EMC Filter
Resolution:
Part number VW3A4416 is an externally mounted EMC filter that will fit these drives.
What is minimum firmware version required for the ATV71 or ATV61 to use the VW3A3316 Ethernet IP card?
Product Line:
VW3A3316
Cause:
ATV71 & ATV61 have minimum firmware required to use the VW3A3316 Ethernet IP card
Resolution:
This communication option card is fully supported with the version V1.5 IE 13 and above of the Altivar 61 firmware. This communication option card is only supported with the version V1.6 IE 19 and above of the Altivar 71 firmware. Specific versions of the Altivar 71 firmware are not supported.
EasyPact EZC and EZD circuit breakers
Cause:
This breaker is popular overseas and there is interest in the US
Resolution:
There are no plans for a general release of the EasyPact EZC or EZD circuit breaker line in North America.
What Padlock Device can be used on the 9001KR9R E-stop Pushbutton?
Product Line:
30 mm push buttons
Environment:
Harmony 30 mm 9001 SK Plastic Push Buttons
Resolution:
9001K62, 9001K162
NOTE: These attachments will not work when the operator is supplied with a 2 1/4 inch diameter mushroom.
AC coil replacement for CAD32 and CAD50
Product Line:
Relays
Environment:
Tesys CAD Control Relays
Cause:
Product selection
Resolution:
Volt = coil part number
12 = LXD1J7
21 = LXD1Z7
24 = LXD1B7
32 = LXD1C7
36 = LXD1CC7
42 = LXD1D7
48 = LXD1E7
60 = LXD1EE7
100 = LXD1K7
110 = LXD1F7
115 = LXD1FE7
120 = LXD1G7
127 = LXD1FC7
200 = LXD1L7
208 = LXD1LL7
220/230 = LXD1M7
230 595 21 LXD1P7
230/240 = LXD1U7
277 781 30 LXD1W7
380/400 = LXD1Q7
400 = LXD1V7
415 = LXD1N7
440 = LXD1R7
480 = LXD1T7
600 = LXD1X7
690 = LXD1Y7
Issue:
What is the product number for a complete through-the-door disconnect device for a GV2P
Product Line:
IEC Contactors and Starters
Environment:
GV2P Manual Starters and Protectors
Resolution:
There are three devices which include mechanism, shaft and handle:
GV2APN01 has a NEMA 1, 12 rating and is black
GV2APN02 has a NEMA 1, 12 rating and is red/yellow
GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow
Where can I buy a EasyPact MVS breaker?
Product Line:
EasyPact MVS circuit breakers
Resolution:
There are no plans for a general release of the EasyPact MVS circuit breaker line in the US.
Circuit Breakers
Masterpact NT/NW
Resolution:
Finger cluster (each): S33166
Cluster grease (12 oz. tube): S48899
Which parts are needed to upgrade a Masterpact NW breaker from a standard trip unit to a Micrologic 3.0A 5.0P 6.0P 5.0H or 6.0H?
Product Line:
Masterpact NW
Resolution:
Both fixed and drawout breakers need connector S33101 and the trip unit:
3.0A S141A
5.0A S143A
6.0A S144A
5.0P S163A
6.0P S164A
5.0H S173A
6.0H S174A
A neutral CT is required if the breaker is applied on a 4-wire system and new trip unit is a 6.0A, 6.0P, or 6.0H.
A neutral CT is also required if the breaker is applied on a 4-wire system and the new trip unit is a 5.0P or 5.0H being used for ground fault alarm.
See attached table for catalog numbers.
Fixed circuit breakers also need the following parts in addition to connector S33101:
External Voltage Sensing S47506 (P and H trip units only, if voltage sensing is required)
Secondary Disconnects (3) S47075 and (1) S47074
BCM S47405 (if Modbus is required)
Drawout circuit breakers also need the following parts in addition to connector S33101:
External Voltage Sensing S48533 (P and H trip units only, if voltage sensing is required)
Secondary Disconnects (3) S47850 and (1) S47849
BCM S48384 (if Modbus is required)
Do we have part numbers for the replacement lens for 9001 type O pilot lights?
Product Line:
Push Buttons and Operator Interface
Environment:
30 mm Type O Pilot lights
Resolution:
Red - 2550420020
Green - 2550420040
Amber - 2550420040
Clear - 2550420010
Yellow - 2550420030
White - 2550430040
Blue - 2550470010
NOTE: All these replacement lens have been discontinued
Set up an ATV61/ATV71 drive with an VW3A3316 Ethernet IP card using assemblies 20 and 70?
Product Line:
Altivar ATV61 and ATV71 with Ethernet VW3A3316 option card.
Environment:
All
Cause:
Needs to set up an ATV61 drive with Ethernet IP card to use Assemblies 20 and 70.
Resolution:
PLC's Ethernet scanner module needs to be configured as follows
Assembly 20 2 words or 4 bytes (output table)
Assembly 70 2 words or 4 bypes (input table)
Configuration size 6
Single INT
Drives programming needs to be excactly like this there are no exceptions
Menu 1.6
Command menu
Reference 1 channel = Com card or NET
Profile= Seperate control
Command swtiching= C312
Command channel 1= Com card or NET
Command channel 2= terminal control
Reference 2 swtiching= C313
Reference 2 channel= AI2 or AI1 ( you choose)
Menu 1.7
Ref 1b switching = channel 1 active (applies only to the ATV61)
See the tables below for the assembly mapping for the Command word and for reading the ETA status.
Addtional important information about setting the speed referece from the network.
ATV32 part number for the Ethernet IP/Modbus TCP/IP option card.
Product Line:
Altivar 32 series drives.
Environment:
All models, All serial numbers.
Cause:
Part number unknown.
Resolution:
The part number for the combination Ethernet IP/Modbus TCP/IP card for the Altivar 32 series drives is VW3A3616
Installation and User Guides for Wiser Home Managment System Thermostats
EER56000, EER56100, EER58000
Product Line:
Wiser Home Management System
Environment:
Residential Single Family Home
Cause:
Solutions to many common questions can be found in the documentation.
Resolution:
User Guides and Installation Bulletins are attached.
What is the replacement handle for 9001BR control station?
Product Line:
Push Buttons and Operator Interface
Environment:
Harmony Control Stations
Resolution:
Operating lever assembly part number is 3110111450. Includes the lever, shaft and pin.
Transfer configuration from an ATV56/ATV66/ATV16/ATV18 to any current drive product.
Product Line:
ATV56 Altivar ATV66 ATV18 ATV16 ATV28 ATV11
Environment:
All
Cause:
Replacement Drive
Resolution:
No. You must manually program the new drive.
Most features and functions in the old drives can be found in the new ones, but some wiring changes may be required.