Standard Series, Single Switch Socket Outlet, 250V,10A, Skirt Mount

Standard Series, Single Switch Socket Outlet, 250V,10A, Skirt Mount White Electric

Item Number: 16-WE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product or component type

switched socket

Product brand

Clipsal

Surface finish

glossy

Sustainable offer status

Green Premium product

Physical

Control type

ON/OFF button

Number of gangs

1 gang

Pin number

3

Number of power socket outlets

1

Actuator

switch|rocker

Fixing mode

by screws

Local signalling

without light indicator

Mounting position

horizontal

[ue] rated operational voltage

250 V AC

[in] rated current

10 A

Depth

14 mm

Length

98 mm

Width

45 mm

Fixing center

78 mm

Standards

AS/NZS 3100|AS/NZS 3112|AS/NZS 3133:approval number S/1

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP120506EN

Circularity profile

N/A

Material

Material

plastic

Others

Commercial status history

SESA301466 | Wed Aug 14 22:49:00 EDT 2024 | From Import Local | From 18 to 19

Package 1 bare product quantity

1

Package 2 bare product quantity

10

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

2.5 cm

Package 1 width

4.5 cm

Package 1 length

10 cm

Package 1 weight

62 g

Unit type of package 2

BB1

Number of units in package 2

10

Package 2 height

7.7 cm

Package 2 width

10.5 cm

Package 2 length

19.5 cm

Package 2 weight

660 g
Show all specifications

Frequently Asked Questions

hide show

How can I connect SoMove to an Altivar Process drive via Ethernet TCP/IP or Profinet?

Issue:
Connecting SoMove to the VFD using the Ethernet network connection.
 

Product Line:
ATV61 
ATV71 
ATV630
ATV930
ATV320
ATV340
ATV32

Environment:
Ethernet IP or Profinet option installed.
VW3A3316, VW3A3320, VW3A3627 VW3A3720

Cause:
Drive is not detected when attempting to connect.

Resolution:
See attachment for screenshots showing SoMove V2.9.4

STEP 1
Turn OFF your computers firewall before starting so you will have access to your Ethernet port. 
somove Ethernet 32

STEP 2
Edit Connection on your computers ethernet port and setup IP address in the Altivar Drive using an HMI.
Computer or PC setup:
Example setting up your PCs IP address.
Search Ethernet settings
-Change adapter options
- Choose the Ethernet port you want to use.
-Choose Properties
-Make sure IPV4 and IPV6 are both checked. 
-Double click on the IPV4 settings
-Select "Use the following IP address" and now enter in an IP address for your PCs ethernet port. 
Note this IP address needs to match your Drives IP address up to the last octet. 
Drives IP address= 10.172.86.1 (for the Drive) and your PC's IP address = 10.172.86.10 (your computer)
Subnet address= 255.255.255.0
-Choose ok
Somove Ethernet 1

Drive Setup
Example set your Drives IP address using the remote HMI under the Ethernet settings in the programming. 
Type=Fixed
IP address= 10.172.86.1 (for the Drive) 
Subnet address= 255.255.255.0
-Power cycle your Drive after changing the IP address 


STEP 3 
Open up Somove 2.9.4 or newer and setup your "edit connection/scan" settings.
-Click on  "edit connection/scan"
-Choose Modbus TCP double click
-Choose the advanced settings (small gear wheel icon).
-Choose More
-Choose Scan tab
-Now type in your Drives IP address example 10.172.86.1  
-Choose Single Scan and enter 1 
-Apply and OK
-Ok again 
Somove Ethernet 2

STEP 4 
-Now Scan for the Device to see if your PC finds the Drive. 
-double click on the picture of the drive to connect and load from the device.

Somove Ethernet 3

NOTE: If your Drives ATV630 or ATV930 Firmware is version V3.3IE or above it will now include cyber security features and you will have to enter a password before connecting to the drive other Ethernet or Profinet. You can find this unique password on your HMI under the Communications menu, Embedded Ethernet configuration, and find SECE.  SECE select OK on the HMI and then select WDPE and press ok.  Your will now see your unique password example "iY^Nm9cV"
This password is temporary and will need to be changed and remembered.

The USERNAME: ADMIN (all caps)
The Password: iY^Nm9cV (for this example only) 

FAQ cyber security 1

FAQ cyber security 1a

FAQ cyber security 1n

Please read and understand before checking OK. 

Somove ethernet 4

Somove is loading settings from the Drive to your Somove on your PC. 

somove ethernet 5b


Your are now connected to the Drive when the bar across the top turn's orange. 

Somove Ethernet 6a


Please be aware that you will be required to enter a password when you connect via Ethernet or Profinet if your Process Drive is version V3.3IE or higher so if you live in an area or work for a company that does not require or mandate having a password for Ethernet or Profinet for cyber security you can disable the feature if desired.  Otherwise leave the feature active which can offer the best cyber security. 

FAQ cyber security 1b


Done.  


NOTE:  

This example should work using. 
-Ethernet TCP
-Ethernet IP
-Profinet

 

 
 
 
 
 

How do you order a Masterpact NW or NT circuit breaker?

Issue:
What is the process for ordering a Masterpact NW or NT circuit breaker?

Product Line:
Circuit Breakers

Resolution:
Masterpact circuit breakers cannot be ordered by catalog number.  A Schneider distributor or sales office must enter the order via the online product selector in My Schneider, SE Advantage, or Quote to Cash.
Information they need includes the certification standard (UL, ANSI, IEC), fixed or drawout, ampacity, AIR required, trip unit functions or type, accessories, connectors, and other customer specifications.

The attached decoder will assist in breaking down a catalog number to its component parts.  With knowledge of the breaker's construction it will be possible to use the Q2C or SE Advantage product selector to select, quote, and order the breaker.  DO NOT try to build a catalog number using the decoder.  A number generated using the decoder will be prone to error due to possibly selecting components and features which are mutually exclusive, and the number will have no value for quotation or ordering even if valid.

Required information for placing an order can be found on the attached RFQ (Request for Quote) or RFQ - DC for DC rated Masterpacts.

Why is the LCD display screen blank on a Micrologic Power or Harmonic type trip unit on a Powerpact P frame, R frame, or Masterpact circuit breaker?

Issue:
Why is the display blank on the trip unit?

Product Line:
Powerpact P frame, Powerpact R Frame, Masterpact NT, Masterpact NW

Resolution:
The LCD display on a Micrologic P or H trip unit will be blank unless the trip unit is energized.  Energization requires one of the following sets of conditions:
  1. The trip unit is energized by an external 24 Vdc applied to terminals F1-F2 (F1 negative-F2 positive).  See attachment for location of terminals.
  2. The trip unit is energized by an FFTK or HHTK test kit
  3. There is at least 100 V between two phases, AND the load reaches approximately 20% of the breaker's rated current.
  • Note that the display will not power up with primary injection testing unless one of the conditions in bullet 1 above is met.
  • Note that Ammeter trip units do not require external power and the display will come on with sufficient current flow alone.
See the following bulletins for more information on these trip units.
 

Where can I find Short circuit current ratings (SCCR) information for ATV312 drive?

Issue:
ATV312 Short Circuit Current Ratings (SCCR) information.

Product Line:
Altivar 312

Environment:
All

Cause:
Short circuit protection for drives

Resolution:
Please see attached for information.

Can ground fault be disabled on a Micrologic 6.0A, 6.0P, or 6.0H trip unit on a Masterpact NT/NW or PowerPacT P/R frame circuit breaker?

Issue:
Can the ground fault pickup be disabled on a Micrologic 6.0A (ammeter), 6.0P (power), or 6.0H (harmonic) trip unit?
 
Product Line:
Micrologic, Masterpact, Powerpact
 
Resolution:  
No. To eliminate ground fault protection, replace the trip unit with a 5.0 of the same type.  
For ground fault alarm, replace the trip unit with a 5.0P or 5.0H trip unit and use an M2C (S64273) programmable contact module or I/O module(s) (LV434063). 

Note:  if ground needs to be temporarily disabled for primary injection testing, refer to FA98682.

What are components in the 9001KYK116?

Issue:
Identify the parts break down of a 9001KYK116

Product Line:
30mm, 9001KY/SKY Control Stations

Environment:
Pushbuttons and Operator Inteface

Resolution:
9001KY1 - Enclosure
9001K15 - Emergency Break Glass Operator
9001KA1 - 1NO and 1NC Contact Block
9001KN799RP -  Legend Plate (Special Marking)

Guard for Mushroom operators 9001KR16 or 9001SKR16

Issue:
Which guard should be used with the 9001KR16 or 9001SKR16?

Product Line:
Push Buttons and Operator Interface

Environment:
9001K and 9001SK 30mm operators

Resolution:
The 9001K56YM or the 9001K56RM are suitable guards for this operator

What is a replacement mushroom lens for a XB2BN or standard ZB2BW illuminated mushroom button?

Issue:
Is the mushroom lens for a XB2BN or standard ZB2BW illuminated mushroom button replaceable?

Product Line:
Legacy Push Buttons

Environment:
Obsolete 22mm

Resolution:
Replacement mushroom lenses were as follows:
WhiteW40429264001
GreenW40429264003
RedW40429264004
AmberW40429264005
BlueW40429264006
ClearW40429264007

NOTE: Some of them are already obsolete

What is the guard for a 22mm push-pull mushroom head operator, similar to cat. no. 9001 K56*M?

Issue:
Identify the part number for a guard for a 22mm push-pull mushroom head operator.

Product Line:
Harmony 22mm, XB4, XB5, Push Buttons

Environment:
Push Buttons and Operator Interface

Resolution:
Catalog number ZBZ160* is a metal guard for 40mm mushroom head operator.
ZBZ1600Chrome Plated
ZBZ1602Black
ZBZ1604Red
ZBZ1605Yellow
ZBZ1606Blue

What is the difference between A9D32620 and A9D33620 RCBO Acti 9 devices?

 
 

A9D33620 = SI (Super Immunised)
A9D32620 = Type A (AC or pulsating DC)
Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
Type Si RCBO = With all the features of a Type A device, “Si” type Super Immunised earth leakage protection range has been specially developed to be used with loads or in environments causing disturbances. Examples are lightning or switching surges, harmonics generated by increasing number of loads and constant load leakage current from electronic ballasts, speed drives, computers, etc. The Si increases safety and allows improved continuity of supply.
 

What size is the conduit entry in the 9001BR enclosures?

Issue:
Need to know the size of the conduit entry in the 9001BR enclosures?

Product Line:
Push Buttons and Operators Interface

Environment:
Class 9001 Type BR Control stations

Resolution:
1/2-14 NPT Pipe tap in bottom only.

ATV16 drive will not power up or display is blank.

Issue:
ATV16 drive will not power up or display is blank.

Product line:
Altivar Machines, Altivar 16

Environment:
All

Cause:
External control circuits are shorting out internal power supply or Power board is bad.

Resolution: 
Remove all of the control wires to see if the display comes back up. Check all supply voltages. There are no replacement parts available. They will need to replace it with a new drive.
 

What product line would best replace an ATV16 VFD?

Issue:
ATV16 VFD replacement.

Product Line:
ATV16 Altivar 16

Environment:
All models

Cause:
Seeking replacement VFD for the obsolete ATV16.

Resolution:
Recommend the ATV320 product line.

Do power wires need to be installed in separate conduits for AC drives?

Issue:
Power wires installation for AC drives

Product Line:
Altivar drives

Environment:
All

Cause:
Installation

Resolution:
Good wiring practice requires the separation of control wiring from power wiring. Power wiring to the motor must have the maximum possible separation from all other power wiring, whether from the same drive controller or other drive controllers. Do not run power and control wiring, or multiple power wiring, in the same conduit. This separation reduces the possibility of coupling electrical transients from power circuits into control circuits or from motor power wiring into other power circuits.
Use of special shielded cables does not reduce or eliminate the need for cable separation.
Please refer to the installation documents for more information.

How to Calculate the Required Capacity kVA Rating or Amperage Capacity for Single and Three Phase Transformers

Issue:
Calculation of kVA capacity for a Single or Three Phase Transformer, based on Winding Voltage and Amperage information.
 
 
Environment:
Applies to all Single and Three Phase Transformers.
 
Cause:
kVA sizing must often be calculated from Primary or Secondary Winding Voltage and Amperage information.
 
Resolution:

This Frequently Asked Question offers three different methods for finding the needed information:

1.  
This link on the Schneider Electric Website is a Transformer Data Calculator:

https://tools.se.app/transformerdata/index.html?language=en&country=usa#/transformer-data

There are also the following methods for calculating or finding the Required Capacity kVA Rating or Amperage Capacity for Single and Three Phase Transformers:

2.  To determine kVA you must have at least two pieces of information:  
  1. the load line-to-line voltage (V)
  2. the maximum load phase current (I)

Single Phase Transformers: kVA = (V * I) /1000
Three Phase Transformers:  kVA = (V * I * 1.732) / 1000
where 1.732 is the simple numerical value for the square root of 3 (1.7320508...)
Then round up to the next standard 3ph kVA rating as found in Section 14 of SquareD/Schneider Electric Catalog, Digest 178 .

Single Phase Transformer Example: V = 240, I = 175; Therefore: kVA = (240 x 175) / 1000 = 42 kVA
This calculates to 42 kVA, thus we round up to a standard Single Phase size 50kVA.  From the Digest, an EE50S3H will satisfactorily serve this load.

Three Phase Transformer Example:  V = 208, I = 175; Therefore: kVA = (208 x 175 x 1.732) / 1000 = 63.05kVA
This calculates to 63+ kVA, thus we round up to a standard Three Phase size 75kVA.  From the Digest, an EXN75T3H will satisfactorily serve this load.

Note:  This is a sample kVA calculation and does not take into account possible special load requirements, such as found with motors or some medical equipment, or other specialty applications.


Amperage provided for a given KVA can be determined by similar techniques:

Single Phase Example:  Using a 50 KVA Single Phase Transformer as a starting point.  50KVA is equal to 50,000 VA. (K= 1,000)  The full value in VA, 50,000 is then divided by the Voltage 240V = 208 Amperes.  This is a "Two Step Division", technique:  VA / Voltage = Amperage

Three Phase Example:  Using a 75 KVA Three Phase Transformer as a starting point.  75 KVA is equal to 75,000 VA. (K= 1,000)  The full value in VA, 75,000 divided by 1.732 = 43,302, which is then divided by the Voltage 208V = 208.2 Amperes.  This is a "Three Step Division", technique:  VA / 1.732 / Voltage = Amperage


3.  As an alternative to these calculations, you may prefer to use the charts below.  Standard KVA sizes are shown on the left margin, Standard Line-to-Line Voltages are shown along the top margin. 

Chart Example:  Using the numbers from the earlier Three Phase Transformer Example V=208, I=175.  Use the chart titled "Three Phase Low Voltage Dry Type Transformers".  Following the 208V top margin entry, and reading down vertically, it is seen that the first entry in that 208V vertical column that will cover 175A, and then some, is 208A, which indicates a 75 KVA Transformer, shown in the next over vertical column to the left.

See pages 3 & 4 of document 7400HO9501 "Looking for Low Voltage Transformer Solutions" for more information and conversion tables.
kVA Table

When did the ATV16 Drive become obsolete?

Issue:
ATV16 obsolescence

Product line:
ATV16, Altivar 16

Environment:
All models.

Cause:
Determine age of unit, product obsolescence

Resolution:
The ATV16 became obsolete in 1996. The current replacement is the ATV12 or ATV320, depending on the application. There are some differences that should be reviewed by the customer such as wiring, dimensions, and ratings.

Is it possible to field install the DC choke on the D version of the ATV61HD90N4D drives?

Issue: 
Installation of DC choke on the D version of the ATV61HD90N4D.

Product Line:
Altivar 61, ATV61

Environment:
ATV61HD90N4D

Cause:
The AV61HD90N4D was ordered which ships without the DC choke.

Resolution:
The DC choke for this part is not available for sale. Recommended solution is to add a 5% input line reactor, separately mounted.

What are the part numbers of the measuring board for ATV61HC16N4 and ATV71HC13N4 drives?

Issue:
Needs the part numbers of the measuring board for the ATV61HC16N4 and ATV71HC13N4 drives

Product Line:
ATV61 and ATV71

Environment:
All

Cause:
Failed measuring board component within the drive.

Resolution:
The part number for the measuring board is VX5A71HC13N4 or VX5A71HC13N4F (For Fuji parts)
When a replacement Measurement board is needed, the serial  number of the VFD needs to be verified.
 
If the 8th digit of the Serial number is a "2" as shown below than the replacement part number must have an "F" suffix.
See Attachment
 

What is the replacement lens cap for ZB2BW extended head push button?

Issue:
What is the replacement lens cap for ZB2BW extended head push button?

Product Line:
Harmony Pushbuttons

Environment:
All Products

Cause:
Product selection

Resolution:
The ZB2 product line is discontinued.  The replacement heads are no longer available

ZB2BW931 - White
ZB2BW933 - Green
ZB2BW934 - Red
ZB2BW935 - Ambler
ZB2BW936 - Blue
ZB2BW937 - Clear

Video: How do you install an option card on the Altivar ATV61 and ATV71 drives?

Issue:
Trying to install an option card on a ATV61 and ATV71 drive. 

Product Line:
Altivar ATV61 and ATV71 drives

Environment:
All

Cause:
N/A

Resolution:



Remove the front display cover by pushing down on the two tabs on the top of the drive.
Once the front cover has been removed you can now install your serial communications card or extended IO card.
Once the Option card has been installed you can not reinstall the front cover by pushing down on the cover until  you hear it click into place. 
 

Where can I download the EDS files for the Ethernet IP, Devicenet, CANopen, or EtherCAT?

Issue:
Where can I download the EDS files for the Ethernet IP card?

Product Line:
ATV61, ATV71, ATV32, ATV Process

Environment:
All

Resolution:
Use this link to access the Global website where EDS files are available for download.  Be sure to download the EDS file that matches your Drive and Product Version.

https://www.schneider-electric.us/en/download/search/?docTypeGroup=3587139-Software%2FFirmware&docType=1555901-EDS+Files

You will need to find out your drive's product version to choose the correct EDS file.

Example:  In the ATV61 or ATV71; go to menu 1.11 in the drives menu enter
find the product Vxxxxxxxxx 

This product version will need to be the version of the EDS file you download for that specific drive.

How can you break down the ETA status word 3201 on the ATV61 and ATV71 drives?

Issue:
Break down of ETA  status word 3201 on the ATV61/ATV71 drives

Product Line:
Alitvar ATV61 and ATV71

Environment:
With Profibus option card

Cause:
Needs to know the bit breakdown for the ETA status word.

Resolution:
ETA status word for Word 3201
bit 0= Reserved
bit 1= Ready
bit 2= Running
bit 3= Fault
bit 4= Power section line supply present
bit 5= Reserved
bit 6= Reserved
bit 7= Alarm
bit 8= Reserved
bit 9= Command or Ref via network
bit 10= Referenced reached
bit 11= Reference outside of limit
bit 12= Reserved
bit 13= Reserved
bit 14= Stop via Keypad stop button
bit 15= Direction of motor  1=reverse 0=forward.

What does Communication Report value 07 for a Read_Var instruction inside Control Expert suggest?

The reports with a value between 16#01 and 16#FE concern errors detected by the processor that executed the function. 16#07 suggests that there is a problem in sending to the destination, which mean's this error could be caused when port 502 of Modbus/TCP server cannot be connected.

1

Can the GV* starters be used on 50 hertz applications?

Issue:
GV* Starter for 50/60hz application

Product Line:
Motor Starters and Protectors

Environment:
PowerPact™ Manual Starters

Resolution:
Yes, these starters are rated for 50/60 hertz.

This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

Where can I find the spare parts manual for the ATV61HC16N4 and ATV71HC13N4 drives?

Issue:
ATV61HC16N4 and ATV71HC13N4 spare parts manual.

Product line: 
Altivar ATV61HC16N4 and ATV71HC13N4


Environment: 
ATV61HC16N4 and ATV71HC13N4 

Cause:
Someone needs a copy of the services manual for the ATV61HC16N4 and the ATV71HC13N4 drives.

Resolution:
Instruction bulletin 30072-452-78 is attached.
 

Where can I find programming assistance to set up an ATV61/ATV71 drive with an VW3A3316 Ethernet IP card using assemblies 21 and 71?

Issue:
Setup VW3A3316 on ATV61/71 using assemblies 21 and 71.

Product Line:
Altivar ATV61 and ATV71 with VW3A3316 option card

Environment:
All

Cause:
Basic set up assistance on using the Ethernet IP VW3A3316 card on the ATV61 or ATV71 drive.

Resolution:
First, make sure that the Ethernet scanner module is set up for assemblies 21 and 71
Assembly 21= (output table) 2 words (4 bytes)
Assembly 71= (Input table) 2 words (4 bytes)

Drive program has to be as follows ( there are no exceptions when using these assemblies ):
Menu 1.6
Ref 1 channel = com card
Profile = Separate
CMD switching = C312
CMD channel 1 = com card
CMD channel 2 = terminal mode
Ref 2 switching = C313
Ref 2 channel 2 = AI1 or AI2 (do not leave this blank)

Commands to start the drive will be bits 0, 5 and 6   or HEX 0061  or DEC 97
Speed command is in RPMs and is the 2nd word in the output table. 

What is the best alternative for 5012S164/4LWE?

If you are after a replacement electronic switch for a 5012S164/4L-WE then order the standard item “B5034MNLPCB-WE” which contains a PCB Assy plus the Rear Cover.

If you are after an equivalent to a 5012S164/4L-WE the closest we have can be achieved by ordering 1 x “B12/30/6-WE” + 3 x “5031NMML” + 9 x “5031NMS”




 

If just for replacement then you could get B503xNL and remove the Metal Plate and just use the gang switch to replace the old unit.


B5031NL, B5032NL, B5034NL


 

How do you fix Socket error when enabling Dali Mapping in PICED?

DALI mapping

5080CTC Colour V2/3 touch screen controlling dalicontrol

 

 

If having socket error when enabling Dali Mapping

Go into window services and stop Dalibuilding scheduler


 

Why is there a voltage present at the terminals of the open contact of an IHP digital time clock.?

The new generation programmable time switches (CCT15720, CCT15721, CCT15722, CTT15723, CCT15850, CCT15851,CCT15852, CCT15853, CCT16650 and CCT15652) integrate the O-crossing technique. This is an electronic procedure enabling the circuit to be opened at zero current, which enables the electromechanical contact to be operated off-load.

This is used to avoid the inrush currents of certain loads, particularly lighting.

This solution involves a low leakage current traveling through the electronics which generates residual voltage at the contact terminals, even when open. This can cause problems when very low loads (small relays, LEDs, etc.) are operated, as the receiver may be "held on" by this spurious voltage. 

Note:
For this type of application (low load), a conventional electromechanical programmable time switch should be used.

What type of backup battery Is need for a DCBM2-1608

Over 7-10 years the battery requires replacing else if there is a power failure you’re risking losing time and all programming on the unit. 

 

The replacement battery is CR2477N 



What is part number for mounting block to suit C2016/2?

Unfortunately, No mounting block available.
For more information see:https://www.clipsal.com/products/detail?CatNo=C2016/2&tab-document-1=0&itemno=C2016/2-WE
switched socket twin skirting 10a

What does the 16AX mean on the PDL 681MT16WH

AX rating is for fluorescent and inductive loads

Can I purchase end caps for the Clipsal 900/25/16 trunking?

Yes, the part number for end plugs is Clipsal 900/25/16P.

image.png

Please go to the website via the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=900/25/16P&itemno=900/25/16P-WE&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=900/25/16P&itemno=900/25/16P-WE&tab-document-1=0

How do you change the carrier switching frequency in an ATV66 drive?

Issue:
Change the carrier switching frequency in an ATV66 drive

Product Line:
Altivar ATV66

Environment:
All

Cause:
Needs to change the switching frequency because of motor noise.

Resolution:
The only way to change carrier frequency is to go from CT or VT to VTLN or NOLD in menu 7.13.
There is no separate parameter available for switching frequency adjustment.
Refer to the ATV66 user manual VD0C06S305C  page 61.


CTA-ID : 2018068

What is part number VW3A4416?

Issue:
What is part number for an EMC filter for the Altivar 12 drives?

Product Line:
Altivar 12, ATV12, ATV11

Environment: 
ATV12H018F1
ATV12H037F1
ATV12H018M2
ATV12H037M2
ATV12H055M2
ATV12H075M2
ATV12P037F1
ATV12P037M2
ATV12P055M2
ATV12P075M2

Cause:
EMC Filter

Resolution:
Part number VW3A4416 is an externally mounted EMC filter that will fit these drives.

Video: What is minimum firmware version required for the ATV71 or ATV61 to use the VW3A3316 Ethernet IP card?

Issue:
What is minimum firmware version required for the ATV71 or ATV61 to use the VW3A3316 Ethernet IP card?

Product Line:
VW3A3316

Cause:
ATV71 & ATV61 have minimum firmware required to use the VW3A3316 Ethernet IP card

Resolution:
This communication option card is fully supported with the version V1.5 IE 13 and above of the Altivar 61 firmware. This communication option card is only supported with the version V1.6 IE 19 and above of the Altivar 71 firmware. Specific versions of the Altivar 71 firmware are not supported.

Are EasyPact EZC or EZD circuit breakers for sale in the USA or Canada?

Product Line:
EasyPact EZC and EZD circuit breakers

Cause:
This breaker is popular overseas and there is interest in the US

Resolution:
There are no plans for a general release of the EasyPact EZC or EZD circuit breaker line in North America.

Is there a padlock device for the 9001KR9R?

Issue:
What Padlock Device can be used on the 9001KR9R E-stop Pushbutton?

Product Line:
30 mm push buttons

Environment:
Harmony 30 mm 9001 SK Plastic Push Buttons

Resolution:
9001K62, 9001K162
NOTE: These attachments will not work when the operator is supplied with a 2 1/4 inch diameter mushroom.

What is the replacement AC coil for CAD32 and CAD50 relay?

Issue:
AC coil replacement for CAD32 and CAD50

Product Line:
Relays

Environment:
Tesys CAD Control Relays

Cause:
Product selection

Resolution:
Volt = coil part number
12 = LXD1J7
21 = LXD1Z7
24 = LXD1B7
32 = LXD1C7
36 = LXD1CC7
42 = LXD1D7
48 = LXD1E7
60 = LXD1EE7
100 = LXD1K7
110 = LXD1F7
115 = LXD1FE7
120 = LXD1G7
127 = LXD1FC7
200 = LXD1L7
208 = LXD1LL7
220/230 = LXD1M7
230 595 21 LXD1P7
230/240 = LXD1U7
277 781 30 LXD1W7
380/400 = LXD1Q7
400 = LXD1V7
415 = LXD1N7
440 = LXD1R7
480 = LXD1T7
600 = LXD1X7
690 = LXD1Y7

 

GV2P disconnect options

Issue:
What is the product number for a complete through-the-door disconnect device for a GV2P

Product Line:
IEC Contactors and Starters

Environment:
GV2P Manual Starters and Protectors

Resolution:
There are three devices which include mechanism, shaft and handle:
GV2APN01 has a NEMA 1, 12 rating and is black
GV2APN02 has a NEMA 1, 12 rating and is red/yellow
GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow

Are EasyPact MVS circuit breakers for sale in the USA or Canada?

Issue:
Where can I buy a EasyPact MVS breaker?

Product Line:
EasyPact MVS circuit breakers

Resolution:
There are no plans for a general release of the EasyPact MVS circuit breaker line in the US.
 

What is the part numbers for Masterpact NT/NW finger clusters and grease?

Product Line:
Circuit Breakers
Masterpact NT/NW

Resolution:
Finger cluster (each): S33166
Cluster grease (12 oz. tube): S48899
 

Parts needed to upgrade a Masterpact NW breaker from a Micrologic 3.0 or 5.0 to the 3.0A, 5.0P, 6.0P, 5.0H, or 6.0H trip units

Inquiry:
Which parts are needed to upgrade a Masterpact NW breaker from a standard trip unit to a Micrologic 3.0A 5.0P 6.0P 5.0H or 6.0H?

Product Line:
Masterpact NW

Resolution:
Both fixed and drawout breakers need connector S33101 and the trip unit:
3.0A S141A
5.0A S143A
6.0A S144A
5.0P S163A
6.0P S164A
5.0H S173A
6.0H S174A

A neutral CT is required if the breaker is applied on a 4-wire system and new trip unit is a 6.0A, 6.0P, or 6.0H.
A neutral CT is also required if the breaker is applied on a 4-wire system and the new trip unit is a 5.0P or 5.0H being used for ground fault alarm.
See attached table for catalog numbers.

Fixed circuit breakers also need the following parts in addition to connector S33101:
External Voltage Sensing S47506 (P and H trip units only, if voltage sensing is required)
Secondary Disconnects (3) S47075 and (1) S47074
BCM S47405 (if Modbus is required)

Drawout circuit breakers also need the following parts in addition to connector S33101:
External Voltage Sensing S48533 (P and H trip units only, if voltage sensing is required)
Secondary Disconnects (3) S47850 and (1) S47849
BCM S48384 (if Modbus is required)
 

What are the replacement lens part numbers for 9001 type O pilot lights?

Issue:
Do we have part numbers for the replacement lens for 9001 type O pilot lights?

Product Line:
Push Buttons and Operator Interface

Environment:
30 mm Type O Pilot lights

Resolution:
Red - 2550420020
Green - 2550420040
Amber - 2550420040
Clear - 2550420010
Yellow - 2550420030
White - 2550430040
Blue - 2550470010

NOTE: All these replacement lens have been discontinued

Where can I find programming assistance to set up an ATV61/ATV71 drive with an VW3A3316 Ethernet IP card using assemblies 20 and 70?

Issue:
Set up an ATV61/ATV71 drive with an VW3A3316 Ethernet IP card using assemblies 20 and 70?

Product Line:
Altivar ATV61 and ATV71 with Ethernet VW3A3316 option card.

Environment:
All

Cause:
Needs to set up an ATV61 drive with Ethernet IP card to use Assemblies 20 and 70.

Resolution:
PLC's Ethernet scanner module needs to be configured as follows
Assembly 20  2 words or 4 bytes (output table)
Assembly 70  2 words or 4 bypes (input table)
Configuration size 6
Single INT

Drives programming needs to be excactly like this there are no exceptions
Menu 1.6
Command menu
Reference 1 channel = Com card or NET
Profile= Seperate control
Command swtiching= C312
Command channel 1= Com card or NET
Command channel 2= terminal control
Reference 2 swtiching= C313
Reference 2 channel= AI2 or AI1 ( you choose)

Menu 1.7
Ref 1b switching = channel 1 active (applies only to the ATV61)

See the tables below for the assembly mapping for the Command word and for reading the ETA status.


Addtional important information about setting the speed referece from the network.


 

What is the part number for the Ethernet IP / Modbus TCP IP option card for the ATV32 series drives?

Issue:
ATV32 part number for the Ethernet IP/Modbus TCP/IP option card.

Product Line:
Altivar 32 series drives.

Environment:
All models, All serial numbers.

Cause:
Part number unknown.

Resolution:
The part number for the combination Ethernet IP/Modbus TCP/IP card for the Altivar 32 series drives is VW3A3616

Wiser Home Management Thermostat Documentation

Issue:
Installation and User Guides for Wiser Home Managment System Thermostats
EER56000,  EER56100,  EER58000

Product Line:
Wiser Home Management System

Environment:
Residential Single Family Home

Cause:
Solutions to many common questions can be found in the documentation.

Resolution:
User Guides and Installation Bulletins are attached.

 

Replacement handle for 9001BR

Issue:
What is the replacement handle for 9001BR control station?

Product Line:
Push Buttons and Operator Interface

Environment:
Harmony Control Stations

Resolution:
Operating lever assembly part number is 3110111450. Includes the lever, shaft and pin.

Can I transfer the program from an ATV56/ATV66/ATV16/ATV18/ATV28/ATV11 to any of our current drive products?

Issue:
Transfer configuration from an ATV56/ATV66/ATV16/ATV18 to any current drive product.

Product Line:
ATV56 Altivar ATV66 ATV18 ATV16 ATV28 ATV11

Environment:
All

Cause:
Replacement Drive

Resolution:
No.  You must manually program the new drive. 
Most features and functions in the old drives can be found in the new ones, but some wiring changes may be required.