Standard Series Flush Switch 1 Gang, 2 Pole, 250VAC, 10A, Architrave | White Electric
Item Number: 30D-WE
Datasheet
Specifications
Design
Range of product
Product brand
Physical
Device presentation
Number of poles
Device mounting
Number of rocker
Local signalling
[ue] rated operational voltage
Rated current
Marking
Fixing mode
Actuator
Switch function
Reach regulation
Eu rohs directive
Mercury free
Rohs exemption information
China rohs regulation
Others
Package 1 bare product quantity
Package 2 bare product quantity
Packaging made with recycled cardboard
Packaging without single use plastic
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Take-back
Take-back
Product contributes to saved and avoided emissions
Recycled metal content at cr level
Removable battery
Minimum percentage of recycled plastic content
Documents & downloads
hide show-
All
-
Technical Data Catalogues
Frequently Asked Questions
Is the ATV630 (or ATV930) Process drive available with 1 phase input and 3 phase output?
Hide ShowAre the Process drives available with single phase input and 3 phase output?
Product Line:
Altivar 630
Altivar 930
Environment:
Application
Cause:
Wants to know if the ATV630 Process drive is offered in 1 phase input 3 phase output.
Resolution:
The ATV630 is approved for some single phase input, 3 phase output applications.
See the current Annex to the Getting Started with Altivar Process ATV600 document below:
https://www.schneider-electric.com/en/download/document/EAV64300/
This document lists models for 240V and 480V Pump applications.
Note: Do not use ATV630D55M3 and ATV630D75M3 for 1-phase application.
At this time, no ATV900 Process drives are approved for single phase supply. They are designed strictly for 3 phase input power to run a 3 phase motor.
The ATV900 series may be used in conjunction with a 3rd party input bridge from a company like Bonitron (Bonitron Solutions for Schneider Drives) .
Contact Bonitron directly for assistance.
Are conduit kits available for the Altivar Process Drives?
Hide ShowConduit kits for the Altivar Process Drives
Product Line:
Altivar Process Drive (ATV630, ATV930)
Environment:
All serial numbers for Altivar Process Drive
Cause:
N/A
Resolution:
Frame Size 1...4
- Includes IP21 conduit kit already installed on the drive
- Includes IP21 conduit kit but not installed on the drive
Conduit kits are not supplied and have to be ordered:
- Size 6 [ATV630D55M3, ATV630D75M3, ATV930D55M3C, ATV930D75M3C, ATV630C11N4, ATV630C13N4, ATV630C16N4, ATV930C11N4C, ATV930C13N4C, ATV930C16N4C]
- UL type 1 and IP21: VW3A9704
- Size 7A [ATV630C22N4, ATV930C22N4(C)]
- UL type 1: VW3A9212
- UL type 21: VW3A9112
- Size 7B [ATV630C25N4, ATV630C31N4, ATV930C25N4C, ATV930C31N4C]
- UL type 1 without braking unit: VW3A9213
- UL type 1 with braking unit: VW3A9214
- UL type 21 without braking unit: VW3A9113
- UL type 21 with braking unit: VW3A9114
Models of Pelco cameras that have been tested with version 3 NetBotz and BotzWare 4.X
Hide ShowModels of Pelco cameras that have been tested with version 3 NetBotz and BotzWare 4.X
Product Line:
NetBotz
Pelco Cameras
Environment:
NetBotz NBWL0455 and NBRK0570
4.X botzware
Pelco camera support
Cause:
Not all Pelco cameras have been tested with NetBotz 4.0 botzware.
Resolution:
Please note that the NetBotz 3xx and NetBotz NBRK0450/0451 do not support the Pelco integration.
The initially supported Pelco cameras from version 3.x firmware are:
Pelco Camera Model | Product Family | Firmware Version Tested |
IP3701H-2 | IP | Unavailable |
IP110-CHV9 | IP110 Camclosure® | Unavailable |
SD4N-W0 | Spectra Mini IP | Unavailable |
The following is a list of cameras and Pelco firmware that has been tested with BotzWare version 4.0. The Sarix line of Pelco cameras have been added to testing:
Pelco Camera Model | Product Family | Firmware Version Tested |
IXS0C | Sarix IX | 1.7.19.9080-A1.5842 |
IXE20DN | Sarix Enhanced | 1.7.19.9081-A1.5843 |
IX30DN | Sarix IX | 1.7.8.9080-A1.5288 |
IMSOC10 | Sarix IME | 1.7.41.9260-O2.6725 |
SD4N-W0 | Spectra Mini IP | 1.2.15 |
With the release of Botzware 4.2, the following list of additional Pelco cameras and firmwares have also been tested:
Pelco Camera Model | Product Family | Firmware Version Tested |
IMSOC10 | Sarix | 1.8.2 |
IM10C10 | Sarix | 1.8.2 |
IX30DN | Sarix IX | 1.8.2 |
D5118 | Spectra HD | 1.8.2 |
TXB-N | Spectra IV IP | 1.8.2 |
DD4N-W0 | Spectra Mini IP | 1.2.15 |
IP110 | IP110 Camclosure® | 1.0.47 |
IP3701 | IP | 1.0.10 |
The following is a list of cameras and Pelco firmware that has been tested with BotzWare version 4.4:
Pelco Camera Model | Product Family | Firmware Version Tested |
---|---|---|
IM10C10 | Sarix | 1.9.2 |
IMS0C10 | Sarix | 1.9.2 |
D5118 | Spectra HD | 1.9.2 |
IME119 | Sarix Enhanced | 2.1.2.0.8280-A0.0 |
The following is a list of cameras and Pelco firmware that has been tested with BotzWare version 4.5.3:
Pelco Camera Model | Product Family | Firmware Version Tested |
IL 10 | Sarix | Unavailable |
The following is a list of cameras and Pelco firmware that has been tested with BotzWare version 4.6.3:
Pelco Camera Model | Product Family | Firmware Version Tested |
IJP121-1IS | Sarix | 1.16.37 |
Important Note:
Pelco Sarix Pro models that were originally listed as supported do not correctly update the resolution settings presented to NetBotz appliances. NetBotz can no longer support Sarix Pro models due to this limitation of the Pelco camera and they have been removed from this compatibility matrix.
Can I use VW3A3316 Communication card in ATV61/71 for Modbus TCP?
Hide ShowHow does Multidrive link grouping works on ATV Process drives?
Hide ShowIn case of ATV900 it is not possible to use more than one group in the same network. but individual drives can be used in the same network as the multidrive link group.
A simple switch can be used for this kind of application.
What is a Multidrive Link fault (MDLF) on ATV Process Drive?
Hide ShowRemedy:
Check the communication network.
Check the configuration of the multi-drive link function.
Check the firmware and make sure it is consistent on both drives.