Harmony Solid State Relays Solid state relay 50A, panel mount, zero voltage switching, thermal pad, input 180…280V AC, output 48…530V AC
Item Number: SSP3A250P7T
Specifications
Design
Range of product
Product or component type
Physical
Provided equipment
Mounting support
[in] rated current
Connections - terminals
Control type
Insulation resistance
Connections - terminals
- screw terminals: 1 x 0.2...1 x 2.5 mm², (AWG 24...AWG 14) for input
- screw terminals: 1 x 1.5...1 x 10 mm², (AWG 16...AWG 8) for output
Local signalling
Ip degree of protection
Net weight
Width
Height
Depth
Device presentation
Ambient air temperature for operation
Ambient air temperature for storage
Product certifications
- CE
- CSA
- EAC
- UL
- UKCA
Marking
Standards
- IEC/EN 62314
- IEC/EN 60947-4-2
- IEC/EN 60947-4-3
- UL 60947-4-2
- C22.2 No. 14
Eu rohs directive
Mercury free
China rohs regulation
Rohs exemption information
California proposition 65
Others
Life cycle assessment data
If one of the deliverables is not relevant please give the reason
Substance regulation data deliverable
Package 2 bare product quantity
Package 1 bare product quantity
Device short name
Network number of phases
Solid state output type
[uc] control circuit voltage
Output switching mode
[uc] control circuit voltage
Minimum switching voltage
Maximum switching voltage
Response time
- 20 ms (turn-on)
- 30 ms (turn-off)
Input current limits
Output voltage
Load current
Absolute maximum voltage
Surge current
- 715 A for 20 ms
- 750 A for 16.6 ms
Maximum i²t for fusing
- 2520 A².s for 10 ms at 50 Hz
- 2320 A².s for 8.3 ms at 60 Hz
Protection device type
Maximum leakage current
Maximum voltage drop
Dv/dt
Cos phi
Motor power hp
- 1.5 hp 40 °C 120 V AC
- 3 hp 40 °C 240 V AC
- 7.5 hp 40 °C 480 V AC
- 10 hp 40 °C 600 V AC
Motor power kw
- 1.1 kW at 40-40 °C 120 V AC
- 2.2 kW at 40-40 °C 240 V AC
- 5.5 kW at 40-40 °C 480 V AC
- 7.5 kW at 40-40 °C 600 V AC
Capacitance unbalance
Dielectric strength
- 4 kV AC for input/output
- 4 kV AC for input or output to case
[uimp] rated impulse withstand voltage
- 4 kV for input to case
- 6 kV for input/output circuit
- 6 kV for input/output to case
Tightening torque
- 1.2 N.m for input
- 2.5 N.m for output
Thermal resitance
Electromagnetic compatibility
- electrostatic discharge 4 kV criteria B contact discharge conforming to IEC 61000-4-2
- electrostatic discharge 8 kV criteria B air discharge conforming to IEC 61000-4-2
- conducted RF disturbances 10 V, 0.15...80 MHz criteria A conforming to IEC 61000-4-6
- radiated radio-frequency electromagnetic field immunity test 10 V/m, 80 MHz...1 GHz criteria A conforming to IEC 61000-4-3
- surge immunity test 1 kV criteria B output ports line to line conforming to IEC 61000-4-5
- surge immunity test 2 kV criteria B output ports line to earth conforming to IEC 61000-4-5
- surge immunity test 1 kV criteria B input ports line to earth conforming to IEC 61000-4-5
- electrical fast transient/burst immunity test 2 kV, 5kHz criteria B output ports conforming to IEC 61000-4-4
- immunity to voltage dips 0 %/20 ms criteria B conforming to IEC 61000-4-11
- immunity to voltage dips 40 %/200 ms criteria C conforming to IEC 61000-4-11
- immunity to voltage dips 70 %/500 ms criteria C conforming to IEC 61000-4-11
- immunity to short interruption 0 %/5 s criteria C conforming to IEC 61000-4-11
- electrical fast transient/burst immunity test 1 kV, 5kHz criteria B input ports conforming to IEC 61000-4-4
- radiated radio-frequency electromagnetic field immunity test 3 V/m, 1.4...6 GHz criteria A conforming to IEC 61000-4-3
- radiated emission 30...1000 Mhz environment A conforming to IEC 60947-1
- conducted emission 0.15...30 Mhz environment A conforming to IEC 60947-1
- radiated emission conforming to IEC 60947-1
- conducted emission conforming to IEC 60947-1
Flame retardance
Pollution degree
Overvoltage category
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Packaging without single use plastic
Packaging made with recycled cardboard
Lead free
Sustainable packaging
Take-back
Take-back
Product contributes to saved and avoided emissions
Removable battery
Minimum percentage of recycled plastic content
Documents & downloads
hide show-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Installation Instruction
-
End of Life Manual
-
Technical illustration
-
eTechPub
-
Declaration of Conformity
-
Certificates (MSDS)