Harmony XB5R Relay Antenna AC/DC, 5m cable output
Item Number: ZBRA1
This relay antenna is part of the range Harmony XB5R plastic and XB4R metal wireless and batteryless pushbuttons. Installed between transmitter and receiver it is used to increase the range and/or get round obstacles. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65. It makes it ideal for operation in harsh environments.
Datasheet
Specifications
Design
Range of product
Product or component type
Product destination
Warranty
Physical
Transmission frequency
- 2405 MHz for transmitter
- 2405 MHz for receiver
Communication port protocol
Number of channels
Net weight
Ambient air temperature for storage
Relative humidity
Ip degree of protection
Ik degree of protection
Product certifications
- CCC
- BT 2006/95/EC
- UL
- GOST
- CSA
- CE
- C-Tick
Insulation resistance
Reach regulation
Eu rohs directive
Mercury free
Rohs exemption information
China rohs regulation
Environmental disclosure
Circularity profile
California proposition 65
Material
Material
Others
Package 1 bare product quantity
Device short name
Control station application
Colour of base of enclosure
Colour of cover
Level or class
Antenna type
Antenna gain
Maximum sensing distance
Emission power
[us] rated supply voltage
Maximum power consumption in w
Operating position
Status led
- 1 LED green for power ON
- 1 LED green for emission signal
Overvoltage category
Rated short-duration power frequency withstand voltage
[uimp] rated impulse withstand voltage
Electrical connection
Tightening torque
Housing material
Short-circuit protection
Max power consumption in w
Modulation technique
Bandwidth
Cad overall height
Cad overall width
Electrical shock protection class
Pollution degree
Radio agreement
- RSS
- SRRC
- ANATEL, type III conforming to ETSI EN 301 489-3
- ARIB T66, class 2 conforming to ETSI EN 301 489-3
- FCC, category 2 conforming to ETSI EN 300 440-1
- ICASA, category 1 conforming to ETSI EN 300 440-1
Directives
- 1999/5/EC - R&TTE directive
- 2004/108/EC - electromagnetic compatibility
Vibration resistance
- +/-0.5 mm (f= 10-55 Hz) conforming to IEC 60068-2-6
- 6 gn (f= 55-150 Hz) conforming to IEC 60068-2-6
Shock resistance
- 25 gn (duration = 6 ms) for 6000 shocks conforming to IEC 60068-2-27
- 15 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
[ui] rated insulation voltage
Electromagnetic compatibility
- immunity for industrial environments conforming to IEC 61000-6-2
- conducted and radiated emissions class B conforming to CISPR 22
- electrostatic discharge immunity test - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2
- electrostatic discharge immunity test - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2
- susceptibility to electromagnetic fields - test level: 10 V/m (80...2000 MHz) conforming to IEC 61000-4-3
- susceptibility to electromagnetic fields - test level: 3 V/m (80...2700 MHz, distance = 20 m) conforming to IEC 61000-4-3
- electrical fast transient/burst immunity test - test level: 2 kV conforming to IEC 61000-4-4
- 1.2/50 µs shock waves immunity test - test level: 1 kV (differential mode) conforming to IEC 61000-4-5
- 1.2/50 µs shock waves immunity test - test level: 2 kV (common mode) conforming to IEC 61000-4-5
- conducted RF disturbances - test level: 10 V conforming to IEC 61000-4-6
- immunity to microbreaks and voltage drops conforming to IEC 61000-4-11
- radiated emission conforming to ETSI EN 300 440-1
- conducted emission conforming to EN 300-489-1
- conducted emission conforming to ETSI EN 300 489-3
- radiated emission conforming to ETSI EN 300 440-2
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Packaging without single use plastic
Packaging made with recycled cardboard
Scip number
Green premium status for reporting
Weee
Take-back
Take-back
Product contributes to saved and avoided emissions
Removable battery
Carbon footprint (kg.eq.co2 per cr, total life cycle)
Global warming ; total life cycle
Minimum percentage of recycled plastic content
Documents & downloads
hide show-
All
-
CAD Files and Packs
-
Product Brochures
-
Technical Data Catalogues
-
End of Life Manual
-
Environmental Disclosure
-
Installation Instruction
-
Operating Manuals
-
Technical illustration
-
Application Notes
-
eTechPub
-
Declaration of Conformity
-
Certificates (MSDS)
-
Software - Data Library
Frequently Asked Questions
What is the sensing range of Harmony XB5R?
Hide ShowWhat distance limitations our Wireless Push Buttons have?
Product Line:
Push Buttons and Operator Interface
Environment:
Wireless Push Buttons
Cause:
Specification not published in the catalog.
Resolution:
100 meters if the receiver (relay) is not in an enclosure and 25 meters if it is in an enclosure.
Using an Antenna (ZBRA1) would give different range. Please see attachment for further information.
How many ZBRA1 antennae can be used to repeat the signal for the Harmony wireless transmitters and receivers
Hide ShowWhat is the maximum number of ZBRA1 that can be used?
Product Line:
XB5R
Environment:
Wireless Push Buttons
Resolution:
As many as needed. Each unit will receive the signal and repeat it. Since they each have their own power source the amount of repeaters will not diminish the signal strength.
What it the difference between part numbers ZBRA1 and ZBRA2?
Hide ShowWhat is the difference between a ZBRA1 and a ZBRA2?
Product Line:
All Schneider Electric products
Environment:
Products sold and used in the United States
Cause:
Selecting accessories for the wireless push button line
Resolution:
The ZBRA1 is a repeater unit for the push button line, the ZBRA2 is an external antenna for the ZBRN communication access points.