Clipsal - General Accessories, Grommet, Suit 2.5sqmm Ordinary Duty Flexible Cord with Clamp White Electric
Item Number: 38-WE
Datasheet
Specifications
Design
Range of product
Product brand
Product or component type
Physical
Depth
Length
Width
Eu rohs directive
Mercury free
Rohs exemption information
China rohs regulation
Others
Package 1 bare product quantity
Commercial status history
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Unit type of package 3
Number of units in package 3
Package 3 height
Package 3 width
Package 3 length
Package 3 weight
Documents & downloads
hide show-
All
-
Technical Data Catalogues
Frequently Asked Questions
hide showCatch on the fly option in the ATS46, ATS48 or ATS22 Soft Starters.
Product Line:
Altistart ATS46, ATS48 or ATS22 soft starters
Environment:
All
Cause:
Needs to know if you can restart a spinning motor after a power loss?
Resolution:
No, the soft start doesn't`t have catch on the fly.
However, if the motor is already spinning, then there should not be a problem starting it under most circumstances. The initial starting torque is low and allows for motor slip. Often, it will appear that the motor is ``catching on the fly`` because the torque and speed of the motor will increase as the soft starter accelerates.
If the spinning load is reverse of motor direction has high inertia, the motor may overload before the soft starter is able to accelerate it. This would be much the same as if started by means of a full voltage starter.
Where can I buy a Compact NSX breaker?
Product Line:
Circuit Breakers
Resolution:
There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489 (UL 489 is the standard commonly required in the US). In the US, the PowerPacT circuit breakers should be used (PowerPacT breakers are UL, CSA, and IEC rated).
For support on these breakers, Please see the following link to Global Operations where you can select other countries:
http://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page
Checking on the difference between the 9001KM1L* and the 9001KM38L*, both are listed for 120 volts.
Product Line:
9001KM Light Modules
Environment:
Push Button and Operator Interface
Cause:
Product Features
Resolution:
The 9001KM1L* is a transformer style light module with a 6 volt LED lamp for 120 volt AC input. The 9001KM38L* is a resistor style light module with a 12 volt LED lamp for 120 volts AC or DC input.
Latest firmware update for ATV71.......S383 Drive
Product Line
ATV71
Environment:
S383 drives
Cause:
Compatibility table
Resolution:
See the attached document
Need communications module for Masterpact NW circuit breaker
Product Line:
Air Circuit Breakers
Resolution:
S47405 for fixed mount breakers, S48384 for drawout breakers.
9001KM VA Rating for 120V Led light module?
Product Line:
Push Buttons and Operator Interface
Environment:
30mm, 9001KM, 9001K, 9001SK
Resolution:
All 9001KM 120V LED: 9001KM38LR, 9001KM38LG, 9001KM38LY, 9001KM38LW, 9001KM38LL have a 1.4VA rating.
What is the difference between the 8638 and 8639 versions of the enclosed ATS48 series soft starters?
Product Line:
8638 and 8639 style Enclosed ATS48 soft starters.
Environment:
All makes, all models
Cause:
Customer wants to understand all available options
Resolution:
The 8638 version utilizes a fusible main disconnect while the 8639 version uses a circuit breaker main disconnect.
ATS48 fuse size for circuit control going to CL1 and CL2
Product Line:
Altistart 48, ATS48
Environment:
All open style units. All models, All Serial numbers.
Cause:
Selection of Fuses.
Resolution:
ATS48D17Y and ATS48D22Y we recommend Class CC 600V 0.5 A fuses.
ATS48D32Y, ATS48D38Y, ATS48D47Y, ATS48D62Y, ATS48D75Y, ATS48D88Y, ATS48C11Y, ATS48C14Y, and ATS48C17Y we recommend Class CC 600V 0.6 A fuses.
ATS48C21Y, ATS48C24Y, and ATS48C32Y we recommend Class CC 600V 1.0 A fuses.
ATS48C41Y, ATS48C48Y, ATS48C59Y, ATS48C66Y, ATS48C79Y, ATS48M10Y and ATS48M12Y we recommend Class CC 600V, 1.5 A fuses.
See attached file. Information provided in Table 31 (page 83) of document S1A37491 Altistart 48 Y-range Soft Start Controllers Instruction Bulletin.
Applying BCM programmed for 2 wire modbus to a 4 wire modbus system
Product Line:
Powerpact P/R and Masterpact NT/NW breakers with modbus communications
Resolution:
- With a newer Micrologic P or H trip unit, you may reprogram the BCM module to 4w. This requires Micrologic trip unit firmware version 2010AK or newer.
- If the trip unit does not have this option or if it is an A trip unit, you may use a 2w to 4w converter, like CNV-100. See the attached instruction bulletin for more details.
- Schneider sales offices can also order a BCM programmed for 4w Modbus. Order the module number, 33106, in Q2C with a note that you want it programmed for 4w Modbus.
BCM 33106 profile is available only on Q2C Tool. Contact regional field offices to support order submission for customers who are unable to access Q2C.
InF fault causes on the ATS48 softstarter.
Product line:
Altistart 48, ATS48
Environment:
All models, all serial number
Cause:
InF displayed on the unit.
Resolution:
InF is an Internal fault. Try disconnecting the Control Voltage from CL1,CL2 terminals to see if the fault will reset.
This fault appears if the control board cannot determine the soft starts power rating from the information stored in the EEPROM memory chip on the power board.
Possible causes are:
- Loose ribbon cable connection on the Power board or the Control Board. Try remove the control board, check the plugs and pins. Reseat the control board back in place.
A few cases were observed in the field where the ribbon connector got loose due to vibration and caused this InF fault. The ribbon cable has to be reseated to fix the problem.
- The 24VDC is saturated. Remove all connections to +24 terminal and then measure the voltage.
- SCR is shorted. Check Resistance across each SCR.
- If another ATS48 unit is available, try swapping control boards to confirm if the issue stays with the board or the soft start.
- Power rating not recognized. Replace the Power board and/or Control board.
Identifying the coil terminals for an LC1D TeSys D-Line contactor.
Product Line:
D Line contactors.
Environment:
Products sold in the United States.
Cause:
Product features.
Resolution:
The coil terminals are labelled A1 and A2.
Can multiple motors be connected to 1 soft starter?
Product Line:
ATS48 ATS22
Environment:
All
Cause:
Application requirement
Resolution:
Yes.
Size the soft starter for the total full load amps of all motors to be connected.
Provide separate overload protection for each motor.
For ATS48: Make sure the CLP parameter in the drC menu is set to OFF.
For ATS22: Make sure SSC parameter in the Adj menu is set to OFF.
Motor connections to the soft starter output should not be made or broken while the soft starter is running. The resulting sudden change in current will cause problems and possible damage to the soft starter or other equipment.
Issue:
Wondering what would cause the shunt trip breaker to trip on the Enclosed ATS46 and ATS48 soft starters on power up?
Product Line:
ATS48
Environment:
Shunt trip breaker
Cause:
Circuit breaker disconnect is tripping on power up.
Resolution:
The fault relay has a timed on-delay contact that will power the breaker shunt trip coil if the Altistart R1 relay is not opened by the end of delay. The factory sets the delay to 2 sec. If the delay is set too short or the fault relay does not actuate, the shunt coil will energize and trip the breaker. Consult factory wiring schematics.
Consider increasing the delay time on the time delay relay.
If the relay circuits operate properly, consider that the thermal or magnetic elements of the breaker may be tripping it, rather than the shunt coil.
"383" suffix on and ATV71....N4383
Product Line:
ATV71
Environment:
ATV 71H075N4…HD75N4
Cause:
N/A
Resolution:
Variable speed drive for synchronous motor with speed feedback
The drives are supplied as standard for asynchronous motors with or without sensor feedback.
ATV 71H075N4…HD75N4 drives can control not only those motors included in the standard offer, but also synchronous motors with speed feedback, by adding 383 at the end of the reference.
Example: ATV 71H075N4 becomes ATV 71H075N4383.
See available encoder interface cards.
Issue:
ATV71 functional safety standard EN13849-1 compliance
Product Line:
ATV61 /ATV71
Environment:
All
Cause:
None
Resolution:
Power Removal safety function input is a safe torque off input. When PWR is not connected to the 24V, the motor cannot be started (compliance with functional safety standard EN 954-1, ISO 13849-1 and IEC/EN 61508)
Issue:
Programming the R1 or R2 on the ATV31/ATV312 drives.
Product Line:
ATV31 or ATV312
Environment:
All
Cause:
Setting up R1 and R2 relays on the ATV31 or ATV312 drives?
Resolution:
Note: "press Enter" means press in on the dial, and "scroll down" means turn the dial clockwise.
- While at RDY on the drive's display, press Enter
- Scroll down to I/O menu and press Enter
- Scroll down to R1, press enter, and choose your desired setting. Example: FLT is drive fault.
- Scroll down to R2 enter and choose your desired setting. Example: RUN is drive running.
For further detail, please refer to page 50 in the ATV312 Programming Manual.
https://www.schneider-electric.com/en/download/document/BBV46385/
ATS46 or ATS48 using an undersized motor or not using motor.
Product Line:
ATS46, ATS48
Environment:
All
Cause:
NA
Resolution:
A minimum load current is required for SCR conduction. Starter will trip on PHF (Phase Fault) if the motor current draw is less than 10% of the nominal motor current (adjustable down to 5% on ATS48).
A very small motor or motor loads that can not pull adequate current may require a smaller soft starter.
For testing purposes only, the SST parameter can be turned on under Level 3 parameters(drC menu on ATS48). This SST mode will automatically reset to "NO" when power is cycled.
SST will NOT allow the soft starter to operate with no motor.
VA consumption of CL1, CL2 control power on an ATS48
Product Line:
Altistart 48, ATS48
Environment:
All models, All serial numbers.
Cause:
Need to know the power consumption.
Resolution:
ATS48D17Y and ATS48D22Y require 25 Watts.
ATS48D32Y, ATS48D38Y, ATS48D47Y, ATS48D62Y, ATS48D75Y, ATS48D88Y, ATS48C11Y, ATS48C14Y, and ATS48C17Y require 30 Watts.
ATS48C21Y, ATS48C25Y, and ATS48C32Y require 50 Watts
ATS48C41Y, ATS48C48Y, ATS48C59Y, ATS48C66Y, ATS48C79Y, ATS48M10Y and ATS48M12Y require 80 Watts.
Data from Table 31 (page 83) of document S1A37491: Altistart 48 Y-Range Soft Start Controllers Instruction Bulletin
Rating plugs for Micrologic breakers
Product Line:
Molded Case Circuit Breaker
Resolution:
Interchangeable rating plug catalog numbers are as follows:
Long-Time Pick-Up Ir = In x ... (dial setting below)
What is the part number of the Masterpact NT padlock attachment and padlockable Open/Close push button cover?
Product Line:
Masterpact NT breakers
Resolution:
There are 2 options available to use a padlock to lock a Masterpact NT breaker in the Open/Off position. They are padlock attachment S47514 and padlockable Open/Close push button cover S33897.
Push button cover for Masterpact Circuit Breaker
Product Line:
Air Circuit Breaker
Resolution:
The padlockable Open/Close push button cover for NT breakers is catalog number S33897 and for NW breakers, it is S48536.
ATS48 conformal coated components
Product Line:
ATS48 series soft starts
Environment:
All models of ATS48 and ATS48XXXXXS338
Cause:
Information not available in current literature.
Resolution:
Standard ATS48 version has:
- most of the elements of control board coated (except relays, display, some capacitors)
- some of the elements (IC's and others) of power board coated.
This standard coating makes the ATS48 conformed to the environment standard: IEC 60664-1, Pollution Degree 3.
These unit are available in the United States
Special ATS48 version (you can order it by the reference with S338 at the end, ex.: ATS48C25YS338 ) has:
- enforced conformal coating.
This special ATS48xxxxS338 version conforms to: IEC60721-3-3 class 3C1 for aggressive ambience.
These units has NOT been released for sale in the United States
Identifying the difference between LAD4TB and LAD4TBDL
Product Line:
IEC contactors and starters
Environment:
Products sold and used in the United States
Cause:
Identifying the difference between two similar part numbers
Resolution:
The LAD4TB is for 24V AC coils for the Tesys Series LC1D09 through LC1D38 contactors when supplied with G7 voltage code. The LAD4TBDL is 24 vdc bi-directional diode offered as a replacement if for some reason the diode supplied with the Tesys LC1D09 through LC1D38 contactors when ordered with BD or BL voltage code breaks or is no longer working.
Can the TeSys D line be used to control DC loads?
Product Line:
Tesys D contactors
Environment:
Products sold and used in the United States
Cause:
DC power circuit
Resolution:
Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.
Devices are suitable but not UL Listed for DC applications.
More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/
Identifying interlocks to field assemble a reversing contactor
Product Line:
IEC contactors and starters
Environment:
Products sold and used in the United States
Cause:
Field assembling a reversing IEC contactor
Resolution:
Use the LAD9R1V kit for mechanical and electrical interlocking or use the LAD9R1 kit for mechanical interlocking without electrical interlocking. Both include power connections
Identifying coil consumption
Product Line:
IEC Contactors and Starters
Environment:
Products sold and used in the United States
Cause:
Coil consumption data is required
Resolution:
70VA inrush, 7.5VA sealed.
Coil Voltage suffixes for Tesys D contactors LC*D 09/38
Product Line:
IEC Contactors and Starters
Environment:
Tesys D contactors
Cause:
Selection
Resolution:
The following lists the more common voltage suffix codes for these product lines. For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.
AC Volts ___Code AC Volts ___Code
12 ___ J7 208 ___ LE7
21 ___ Z7 220 ___ M7
24 ___ B7 230 ___ P7
32 ___ C7 240 ___ U7
36 ___ CC7 277 ___ W7
42 ___ D7 380 ___ Q7
48 ___ E7 400 ___ V7
60 ___ EE7 415 ___ N7
100 ___ K7 440 ___ R7
110 ___ F7 480 ___ T7
115 ___ FE7 575 ___ SC7
120 ___ G7 600 ___ X7
127 ___ FC7 690 ___ Y7
200 ___ L7
Standard Coil Low Consumption
DC Volts ___Code DC Volts ___Code
12 ___ JD 5 ___ AL
24 ___ BD 12 ___ JL
36 ___ CD 20 ___ ZL
48 ___ ED 24 ___ BL
60 ___ ND 48 ___ EL
72 ___ SD 72 ___ SL
110 ___ FD 96 ___ DL
125 ___ GD 110 ___ FL
220 ___ MD 220 ___ ML
250 ___ UD 250 ___ UL
440 ___ RD
Issue:
ATS48 with 'U' suffix
Product Line:
Altistart 48
Environment:
All models.
Cause:
Customer has ATS48 part number with a 'U' at the end of it
Resolution:
To order in the US with English only literature, the part number was changed for a short period of time to include the U suffix.
There is no difference in products ordered with U and without U suffix. Customers will get the same product.
The suffix U is no longer used to order this part number.
(i.e. ATS48D17YU is the same Soft Starter as ATS48D17Y).
Issue:
Is it ok to use circuit breakers other than those published in the Quick start guide S1A14738 in order to achieve the same short circuit current ratings?
Product Line:
ATS22
Environment:
All models and serial numbers of ATS22
Cause:
None
Resolution:
Only those circuit breakers published in document S1A14738 Quick start guide - Altistart 22 ANNEX for UL 508 market can be used to achieve the short circuit current ratings listed.
Issue:
Looking for the replacement part number for the ATV58 High HP interface board.
Product Line:
Altivar ATV58
Environment:
All ATV58 High HP drives
Cause:
Replacement parts
Resolution:
The interface board part number is VX4A382.
This board fits the ATV58HC10N4 thru ATV58HC33N4 drives.
This part is obsolete with no direct replacement.
Accessories used on GV3ME06 - 63
Product Line:
IEC Contactors and starters
Environment:
GV3 manual motor starters, IEC
Resolution:
Identify the difference in consumption between the standard DC coils and the low consumption DC coils in the TeSys D contactors
Product Line:
TeSys D Contactors and tarters
Environment:
IEC Contactors and Starters
Resolution:
The standard DC coils have a 5.4W burden, and the low consumption coils have a 2.4W burden for the LC1D09 to D38.
If a combination starter is ordered with a Tesys T overload relay will the door of the enclosure have a reset button?
Product Line:
Combination Starters
Environment:
NEMA Combination Starters
Cause:
Product Characteristics
Resolution:
Yes it will, unless the combination starter comes in a NEMA 12/3R which specifically excludes a reset button on the door. This can be seen by looking at the combination starter class and type in the Schneider Electric Digest.
Coil consumption or burden for the Tesys LC1D/2D contactors from 9A - 38A
Product Line:
Contactors and Starters - IEC
Environment:
Tesys D Contactors
Resolution:
All AC coils for the LC1D09 through LC1D38 3-pole contactors ( including ring tongue, quick connect and spring terminal versions ) have an inrush of 70 volt-amps for either 50 or 60 Hertz applications, and a sealed value of 7 volt-amps for 50Hertz applications or 7.5 volt-amps for 60 Hertz applications.
Where can I buy a EasyPact MVS breaker?
Product Line:
EasyPact MVS circuit breakers
Resolution:
There are no plans for a general release of the EasyPact MVS circuit breaker line in the US.
Since the solid-state switches may be incapable of completely blocking the motor power should a fault occur, auxiliary isolation on the line side of the controller is required. Use either a circuit breaker equipped with a shunt trip coil or an electromagnetic contactor. Connect the isolation device to the fault relay of the controller so that it opens the controller power circuit in the event of a controller fault. The isolation device must be capable of interrupting motor locked rotor current.
See link for further product information:https://www.se.com/au/en/product-range/689-altistart-48/
Is there a part number for a solid red knob used on our push pull operators?
Product Line:
Harmony Push Button
Environment:
Harmony 30mm
Resolution:
The 9001R20 (1-3/8`` red mushroom) or the 9001R21 (2-1/4`` red mushroom) can be used for ``solid red`` buttons only.
When used on 9001KR9R or 9001SRK9R operators, 9001R20 and 9001R21 mushroom knobs must be used in conjunction with adapter ring 9001K54 which is available for the purpose at no charge.``)