Electronic thermal overload protection TeSys LR9D 0.1... 32 Amps
Electronic thermal overload protection TeSys LR9D with contactor TeSys LC1D 3P
Electronic thermal overload protection TeSys LR9D with reversing contactor TeSys LC2D 3P
Electronic thermal overload protection TeSys LR9D with contactor TeSys LC1D 3P
Electronic thermal overload protection TeSys LR9D 0.1... 32 Amps
Electronic thermal overload protection TeSys LR9D with contactor TeSys LC1D 3P
Electronic thermal overload protection TeSys LR9D with reversing contactor TeSys LC2D 3P
Electronic thermal overload protection TeSys LR9D with contactor TeSys LC1D 3P

TeSys, Electronic Thermal Overload Relay, 3P - 6.4...32 A

Catalogue Number: LR9D32
Electronic thermal overload protection TeSys LR9D 0.1... 32 Amps
Electronic thermal overload protection TeSys LR9D with contactor TeSys LC1D 3P
Electronic thermal overload protection TeSys LR9D with reversing contactor TeSys LC2D 3P
Electronic thermal overload protection TeSys LR9D with contactor TeSys LC1D 3P
Electronic thermal overload protection TeSys LR9D 0.1... 32 Amps
Electronic thermal overload protection TeSys LR9D with contactor TeSys LC1D 3P
Electronic thermal overload protection TeSys LR9D with reversing contactor TeSys LC2D 3P
Electronic thermal overload protection TeSys LR9D with contactor TeSys LC1D 3P
Retail
$484.28
RRP (Inc. GST)

Specifications

hide show
Range
TeSys
Product name
TeSys LRD
Device short name
LR9D
Product or component type
electronic thermal overload relay
Relay application
motor protection
Product compatibility
  • LC1D09
  • LC1D25
  • LC1D32
  • LC1D38
  • LC1D12
  • LC1D18
    • Thermal overload class
      class 5…30
      Thermal protection adjustment range
      6.4-32 A
      Maximum power consumption in W
      300 mW
      Mounting support
    • under contactor
    • plate, with specific accessories
    • rail, with specific accessories
      • [Ue] rated operational voltage
      • 690 V for power circuit
      • 660 V for signalling circuit
        • [Ui] rated insulation voltage
        • power circuit: 1000 V
        • signalling circuit: 690 V
          • Tripping threshold
            1.25 In conforming to IEC 60947-4-1
            Control type
          • red push-button: stop and manual reset
          • white 2 microswitches: adjustable trip class
          • red knob: automatic reset
          • grey dial: full-load current adjustment
            • Time range
              1.5...4 min - automatic reset time
              [Ith] conventional free air thermal current
              5 A for signalling circuit
              Associated fuse rating
            • 5 A gG for signalling circuit
            • 5 A BS for signalling circuit
              • [Uimp] rated impulse withstand voltage
                Phase failure sensitivity
                phase difference > 40% 3-3 s conforming to IEC 60947-4-1
                Electromagnetic compatibility
              • surge withstand: 2 kV common mode conforming to IEC 61000-4-5
              • resistance to electrostatic discharge: 8 kV conforming to IEC 61000-4-2
              • immunity to radiated radio-electrical interference: 10 V/m conforming to IEC 61000-4-3
              • immunity to fast transients: 2 kV conforming to IEC 61000-4-4
                • Connections - terminals
                • control circuit: screw clamp terminals 1 cable 2.5-2.5 mm² - cable stiffness: solid or flexible - without cable end
                • power circuit: screw clamp terminals 1 cable 16-16 mm² - cable stiffness: solid or flexible - without cable end
                  • Tightening torque
                  • control circuit: 0.8 N.m on screw clamp terminals
                  • power circuit: 3.1 N.m on screw clamp terminals
                    • Height
                      72.5 mm
                      Width
                      45 mm
                      Depth
                      79.9 mm
                      Net weight
                      0.18 kg
                      Standards
                    • UL 60947-4-1
                    • IEC 60947-4-1
                    • CSA C22.2
                    • GB 14048.4
                      • Product certifications
                      • CSA
                      • CCC
                      • TÜV
                      • cULus
                        • IP degree of protection
                        • IP20 front face conforming to IEC 60529
                        • IP20 front face conforming to VDE 0106
                          • Ambient air temperature for operation
                            -25-70 °C conforming to IEC 60255-8
                            Ambient air temperature for storage
                            -55-80 °C
                            Operating altitude
                            2000 m without derating
                            Mechanical robustness
                          • vibrations 10...150 Hz: 6 Gn conforming to IEC 60068-2-6
                          • shocks 11 ms: 15 gn conforming to IEC 60068-2-7
                            • Dielectric strength
                              6 kV 50 Hz conforming to IEC 60255-5
                              Sustainable offer status
                              Green Premium product
                              REACh Regulation
                              Free of Substances of Very High Concern above the threshold
                              REACh free of SVHC
                              Yes
                              EU RoHS Directive
                              Compliant
                              Toxic heavy metal free
                              Yes
                              Mercury free
                              Yes
                              RoHS exemption information
                              Yes
                              China RoHS Regulation
                               Pro-active China RoHS declaration (out of China RoHS legal scope)
                              Environmental Disclosure
                              ENVPEP1502001EN
                              Circularity Profile
                              ENVEOLI1502001EN
                              WEEE
                              The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                              Documents & downloads

                              hide show
                              Filter items
                              • All

                              • Product Brochures

                              • CAD Files and Packs

                              • Technical Data Catalogues

                              • End of Life Manual

                              • Installation Instruction

                              • Product Environmental

                              • Data Bulletin

                              • Marine Certificate

                              • Declaration of Conformity

                              Frequently Asked Questions

                              hide show

                              What are the wiring terminals on the IEC LRD* overload relays?

                              Product Line:
                              Tesys D line Overload Relays
                               
                              Resolution:
                              The normally closed overload contact are terminals 95 & 96; and the normally open overload contact are terminals 97 & 98.
                              T1 T2 and T3 are the load terminals. 

                              The normally closed control circuit contact will open when there is a fault, this contact is typically used in series with the control circuit. 

                              The normally open trip signal contact closes when a fault occurs which is typically used to control a pilot light, or alarm. 

                               

                              Do we have Type 2 Co-Ordination Chart for the LT47 overload relays?

                              LT47 is not an overload relay but an overcurrent relay, working on a definite time characteristic : current threshold and time based function.

                              We do not have Coordination type 2 tables for LT47.
                              However, LT47 is an overcurrent relay. It performs a motor current measurement through its internal CT. So, LT47 doesn't add impedance to the motor control circuit and the coordination only results from the characteristics of the short circuit protection (fuses or circuit-breaker) and of the contactor. So the coordination tables we publish for LTMR can be used when LT47 is used.

                              What options can I use if the LS1D32 is not available

                              You can use GV2P32 & GV3P32

                              Will the LR3D325 overload relay fit a LC1D65G7 contactor?

                              Issue:
                              Will the LC1D65G7 mount to the LR3D325 overload relay?

                              Product Line:
                              IEC contactors and starters

                              Environment:
                              Products sold and used in the United States

                              Cause:
                              Identifying product compatibility

                              Resolution:
                              No, the LR3D325 is a overload relay with Everlink termination and will direct mount only to the LC1D40A to LC1D65A contactors.


                              CTA-ID : 2050461

                              What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                              Issue:
                              Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                              Product Line:
                              Contactors and Starters IEC

                              Environment:
                              Tesys D contactors and GV manual starters

                              Cause:
                              Spacer required

                              Resolution:
                              Compensation plate catalog number GV1F03, requires 2 pieces snap together.

                              What is the spare coil for LC1D32 240V?

                                LXD1U7

                              Can you remotely reset electronic overloads LR9D?

                              No. You cannot remotely reset LR9D electronic overloads.
                              There is no provision or attachment  to wire external reset button to overload.

                              What is the coil burden for the standard DC control coil for the LC*D09__ through LC*D38__ TeSys contactors?

                              Issue:
                              LC*D09-38 coil consumption

                              Product Line:
                              Contactors and Overload Relays

                              Environment:
                              TeSys™ D Contactors and Overload Relays

                              Resolution:
                              The standard DC coil is 5.4 watts of consumption.

                              What is the part number for LC1D32 contactor with 380V AC Coil?

                              The part number for LC1D32 contactor with 380V AC Coil is LC1D32N7.
                              Even though the LC1D32N7 has a 415V AC coil the coil has + or -  10% rating making the coil range 373.5 - 456.5V AC which is suitable for 380V AC.

                              For more information see:
                              https://www.schneider-electric.com/en/product-range-selector/664-tesys-d/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecatalogue%2Fbrowse.do%3Fel_typ%3Dproduct%26cat_id%3DBU_POW_664_L3%26prd_id%3DLC1D32N7%26scp_id%3DZ000

                              What overload can be used for the LC1D32 contactor @16amps?

                              either the LRD21, 12 to 18 amps.
                              Or the LRD22, 16 to 24 amps.

                              What is the Din rail terminal block to suit the LRD12?

                              The LAD7B106 fits the LRD01 to LRD35 range.
                               

                              Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?

                              ISSUE
                              Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?
                              PRODUCT LINE
                              Auxiliary contacts for the Tesys D line
                              ENVIRONMENT
                              Tesys D-Line and Tesys F
                              CAUSE
                              Fit
                              RESOLUTION
                              These contacts will only fit on the following contactors:
                              Front mount only for LC1D40 through LC1D115 devices and LC1D40A - LC1D65A.
                              Left side mount only to LC1F contactors
                              CTA-ID : 2002751