TeSys D Reversing Contactor-3 Pole AC3 <= 440V 38A, 100 - 250V ACDC Coil

TeSys D Reversing Contactor-3 Pole AC3 <= 440V 38A, 100 - 250V ACDC Coil

TeSys D Reversing Contactor-3 Pole AC3 <= 440V 38A, 100 - 250V ACDC Coil

Item Number: LC2D38KUE

Retail
$1,927.17
RRP (Inc. GST)

Product Dimensions

Width icon

Width90 mm

Height icon

Height85 mm

Depth icon

Depth92 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

reversing contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Device presentation

preassembled with reversing power busbar

[Ue] rated operational voltage

power circuit: <= 690 V AC 25...400 Hz

[Ie] rated operational current

  • 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
  • 38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • Electrical durability

    • 1.8 Mcycles 35 A AC-3 at Ue <= 440 V
    • 0.9 Mcycles 50 A AC-1 at Ue <= 440 V
      • Mounting support

      • rail
      • plate
        • Standards

        • EN/IEC 60947-4-1
        • EN/IEC 60947-5-1
        • UL 60947-4-1
        • CSA C22.2 No 60947-4-1
          • Product certifications

          • CCC
          • CSA
          • EAC
          • UL
          • KC
          • DNV-GL
          • LROS (Lloyds register of shipping)
            • Connections - terminals

            • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
            • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
            • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
            • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
            • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid
            • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid
            • power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm²flexible without cable end
            • power circuit: screw clamp terminals 2 cable(s) 2.5-10 mm²flexible without cable end
            • power circuit: screw clamp terminals 1 cable(s) 1-10 mm²flexible with cable end
            • power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm²flexible with cable end
            • power circuit: screw clamp terminals 1 cable(s) 1.5-10 mm²solid
            • power circuit: screw clamp terminals 2 cable(s) 2.5-10 mm²solid
              • Mechanical durability

                15 Mcycles

                Insulation resistance

                > 10 MOhm for signalling circuit

                IP degree of protection

                IP20 front face conforming to IEC 60529

                Ambient air temperature for storage

                -60-80 °C

                Height

                85 mm

                Width

                90 mm

                Depth

                92 mm

                Net weight

                0.933 kg

                EU RoHS Directive

                Compliant

                Mercury free

                Yes

                RoHS exemption information

                Yes

                China RoHS Regulation

                Product out of China RoHS scope. Substance declaration for your information

                Environmental Disclosure

                ENVPEP1609002

                Circularity Profile

                ENVEOLI1609002EN

                Others

                Product name

                TeSys D Green

                Device short name

                LC2D

                Contactor application

              • resistive load
              • motor control
                • Utilisation category

                • AC-3
                • AC-1
                  • Poles description

                    3P

                    Pole contact composition

                    3 NO

                    Motor power kW

                  • 9 kW at 220...230 V AC 50 Hz
                  • 18.5 kW at 380...400 V AC 50 Hz
                  • 18.5 kW at 415 V AC 50 Hz
                  • 18.5 kW at 440 V AC 50 Hz
                  • 18.5 kW at 500 V AC 50 Hz
                  • 18.5 kW at 660...690 V AC 50 Hz
                    • Motor power hp

                    • 2 hp at 115 V AC 60 Hz for 1 phase motors
                    • 5 hp at 230/240 V AC 60 Hz for 1 phase motors
                    • 10 hp at 200/208 V AC 60 Hz for 3 phases motors
                    • 10 hp at 230/240 V AC 60 Hz for 3 phases motors
                    • 20 hp at 460/480 V AC 60 Hz for 3 phases motors
                    • 25 hp at 575/600 V AC 60 Hz for 3 phases motors
                      • Control circuit type

                      • AC at 50/60 Hz AC/DC electronic
                      • DC AC/DC electronic
                        • [Uc] control circuit voltage

                        • 100...250 V AC 50/60 Hz
                        • 100...250 V DC
                          • Auxiliary contact composition

                            1 NO + 1 NC

                            [Uimp] rated impulse withstand voltage

                            6 kV conforming to IEC 60947

                            Overvoltage category

                            III

                            [Ith] conventional free air thermal current

                          • 10 A (at 60 °C) for signalling circuit
                          • 50 A (at 60 °C) for power circuit
                            • Irms rated making capacity

                            • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                            • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                            • 550 A at 440 V for power circuit conforming to IEC 60947
                              • Rated breaking capacity

                                550 A at 440 V for power circuit conforming to IEC 60947

                                [Icw] rated short-time withstand current

                              • 100 A - 1 s for signalling circuit
                              • 120 A - 500 ms for signalling circuit
                              • 140 A - 100 ms for signalling circuit
                              • 430 A 40 °C - 1 s for power circuit
                              • 60 A 40 °C - 10 min for power circuit
                              • 150 A 40 °C - 1 min for power circuit
                              • 310 A 40 °C - 10 s for power circuit
                                • Associated fuse rating

                                • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                                • 63 A gG at <= 690 V coordination type 1 for power circuit
                                • 63 A gG at <= 690 V coordination type 2 for power circuit
                                  • Average impedance

                                    2 mOhm - Ith 50 A 50 Hz for power circuit

                                    [Ui] rated insulation voltage

                                  • power circuit: 690 V conforming to IEC 60947-4-1
                                  • signalling circuit: 690 V conforming to IEC 60947-1
                                    • Power dissipation per pole

                                    • 5 W AC-1
                                    • 3 W AC-3
                                      • Protective cover

                                        with

                                        Interlocking type

                                        mechanical

                                        Tightening torque

                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                      • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                        • Operating time

                                        • 45...55 ms closing
                                        • 20...90 ms opening
                                          • Safety reliability level

                                          • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                          • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                            • Maximum operating rate

                                              3600 cyc/h 60 °C

                                              Coil technology

                                              built-in bidirectional peak limiting

                                              Inrush power in VA

                                              25-25 VA 50/60 Hz (at 20 °C)

                                              Inrush power in W

                                              18-18 W at 20 °C

                                              Hold-in power consumption in VA

                                              1.6-1.6 VA (at 20 °C) 50/60 Hz

                                              Hold-in power consumption in W

                                              1.1-1.1 W at 20 °C

                                              Heat dissipation

                                              1.1-1.1 W at 50/60 Hz

                                              Auxiliary contacts type

                                            • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                            • type mirror contact 1 NC conforming to IEC 60947-4-1
                                              • Signalling circuit frequency

                                                25...400 Hz

                                                Minimum switching current

                                                5 mA for signalling circuit

                                                Minimum switching voltage

                                                17 V for signalling circuit

                                                Non-overlap time

                                              • 1.5 ms on de-energisation between NC and NO contact
                                              • 1.5 ms on energisation between NC and NO contact
                                                • Compatibility code

                                                  LC2D

                                                  Protective treatment

                                                  TH conforming to IEC 60068-2-30

                                                  Pollution degree

                                                  3

                                                  Operating altitude

                                                  3000 m without derating

                                                  Fire resistance

                                                  850 °C conforming to IEC 60695-2-1

                                                  Flame retardance

                                                  V1 conforming to UL 94

                                                  Mechanical robustness

                                                • vibrations contactor open: 2 Gn, 5...300 Hz
                                                • vibrations contactor closed: 4 Gn, 5...300 Hz
                                                • shocks contactor closed: 15 Gn for 11 ms
                                                • shocks contactor open: 8 Gn for 11 ms
                                                  • Unit Type of Package 1

                                                    PCE

                                                    Number of Units in Package 1

                                                    1

                                                    Package 1 Weight

                                                    1.019 kg

                                                    Package 1 Height

                                                    11.5 cm

                                                    Package 1 width

                                                    11.3 cm

                                                    Package 1 Length

                                                    14 cm

                                                    Unit Type of Package 2

                                                    S02

                                                    Number of Units in Package 2

                                                    5

                                                    Package 2 Weight

                                                    5.425 kg

                                                    Package 2 Height

                                                    15 cm

                                                    Package 2 width

                                                    30 cm

                                                    Package 2 Length

                                                    40 cm

                                                    WEEE

                                                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                                    Halogen content performance

                                                    Halogen free plastic parts & cables product
                                                    Show all specifications

                                                    Documents & downloads

                                                    hide show
                                                    Filter items
                                                    • All

                                                    • Product Brochures

                                                    • CAD Files and Packs

                                                    • Technical Data Catalogues

                                                    • Product Environmental

                                                    • End of Life Manual

                                                    • Installation Instruction

                                                    Frequently Asked Questions

                                                    hide show

                                                    Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                                    Issue:
                                                    Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                                    Product Line: 
                                                    Tesys D Contactors

                                                    Environment:
                                                    IEC contactors

                                                    Resolution:
                                                    The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                                     

                                                    Need a LC2D323U7 reversing contactor

                                                    Use 2 x LC1D32U7 with a LAD9R1V reversing wiring kit

                                                    Are 48 volt AC replacement control coils available for LC2D1801?

                                                    Issue:
                                                    Checking if a 48 volt AC replacement coil is available for an LC2D1801.

                                                    Product Line:
                                                    Tesys D Contactors

                                                    Environment:
                                                    LC1D1810

                                                    Resolution:
                                                    This coil is obsolete. Replace the contactor with the new TeSys product, LC2D18E7. Note this is a functional equal only. Accessories for the old product may or may not fit the new design. Confirm dimensions.
                                                     

                                                    What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                    Issue:
                                                    Identifying maximum voltage of an LC1D contactor

                                                    Product Line:
                                                    TeSys D Contactors

                                                    Environment:
                                                    IEC contactors and starters used in North America

                                                    Cause:
                                                    n/a

                                                    Resolution:
                                                    IThe maximum voltage per UL and CSA is 600VAC. 
                                                     

                                                    What is the code for the 240VAC Coil for the LC1D32 Contactor ?

                                                    Part Code = LXD1U7 
                                                    The LXD1U7 also fits the LC1D09 - D38 Contactors

                                                    What is the interlock for LC1D38***

                                                    As the interlock is not sold separate the part number needed is LAD9R1V

                                                    What is the coil consumption or burden for the Tesys LC*D** contactors?

                                                    * 1 or 2
                                                    ** 09 through 38

                                                    Issue:
                                                    Coil consumption or burden for the Tesys LC1D/2D contactors from 9A - 38A

                                                    Product Line: 
                                                    Contactors and Starters - IEC

                                                    Environment:
                                                    North American Products

                                                    Resolution:
                                                    All AC coils for the LC1D09 through LC1D38 3-pole contactors ( including ring tongue, quick connect and spring terminal versions ) have an inrush of 70 volt-amps for either 50 or 60 Hertz applications, and a sealed value of 7 volt-amps for 50Hertz applications or 7.5 volt-amps for 60 Hertz applications.

                                                    What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                                                    Issue:
                                                    Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                                                    Product Line:
                                                    Contactors and Starters IEC

                                                    Environment:
                                                    Tesys D contactors and GV manual starters

                                                    Cause:
                                                    Spacer required

                                                    Resolution:
                                                    Compensation plate catalog number GV1F03, requires 2 pieces snap together.

                                                    What is the coil burden for the standard DC control coil for the LC*D09__ through LC*D38__ TeSys contactors?

                                                    Issue:
                                                    LC*D09-38 coil consumption

                                                    Product Line:
                                                    Contactors and Overload Relays

                                                    Environment:
                                                    TeSys™ D Contactors and Overload Relays

                                                    Resolution:
                                                    The standard DC coil is 5.4 watts of consumption.

                                                    What is the color scheme of the Tesys D-Line contactors?

                                                    Issue:
                                                    Looking for different color scheme of the Tesys D-Line contactors.

                                                    Product Line:
                                                    Tesys D Contactors

                                                    Environment:
                                                    LC1D contactors

                                                    Resolution:
                                                    Beige and dark gray.
                                                     

                                                    Are the D-Line contactors rated to break DC voltages?

                                                    Issue: 
                                                    Can the TeSys D line be used to control DC loads? 

                                                    Product Line:
                                                    Tesys D contactors

                                                    Environment:
                                                    Products sold and used in the United States
                                                     
                                                    Cause:
                                                     DC power circuit
                                                     
                                                    Resolution:
                                                     
                                                    Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                                    Devices are suitable but not UL Listed for DC applications.

                                                    More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                                     

                                                    What are the stand alone short circuit current ratings on the LC1D** contactors?

                                                    Issue:
                                                    Tesys D SCCR

                                                    Product Line:
                                                    Contactors and Overload Relays

                                                    Environment:
                                                    TeSys™ D Contactors and Overload Relays
                                                     
                                                    Resolution:
                                                    The contactors have a stand alone withstand rating that has been established by UL and is based on the maximum horsepower rating for a given device. However, only combination type starters are supplied with short circuit protective devices having a short circuit current rating.

                                                    They are as follows:
                                                    Horsepower SCCR (A)

                                                    0 thru 1 1,000
                                                    1 thru 50 5,000
                                                    51 thru 200 10,000
                                                    201 thru 400 18,000
                                                    401 thru 600 30,000
                                                    601 thru 900 42,000
                                                    901 thru 1600 85,000
                                                    1601+ 100,000
                                                    Show More