TeSys d 4-pole contactor 80A, EverLink, control connection by screw clamp terminals

Contactor

Catalogue Number: LC1DT80AG7
TeSys d 4-pole contactor 80A, EverLink, control connection by screw clamp terminals
Retail
$2,407.01
RRP (Inc. GST)

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
resistive load
Utilisation category
AC-1
Poles description
4P
Pole contact composition
4 NO
[Ue] rated operational voltage
  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current
      80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
      Control circuit type
      AC at 50/60 Hz
      [Uc] control circuit voltage
      120 V AC 50/60 Hz
      Auxiliary contact composition
      1 NO + 1 NC
      [Uimp] rated impulse withstand voltage
      6 kV conforming to IEC 60947
      Overvoltage category
      III
      [Ith] conventional free air thermal current
    • 10 A (at 60 °C) for signalling circuit
    • 80 A (at 60 °C) for power circuit
      • Irms rated making capacity
      • 140 A AC for signalling circuit conforming to IEC 60947-5-1
      • 250 A DC for signalling circuit conforming to IEC 60947-5-1
      • 1000 A at 440 V for power circuit conforming to IEC 60947
        • Rated breaking capacity
          1000 A at 440 V for power circuit conforming to IEC 60947
          [Icw] rated short-time withstand current
        • 520 A 40 °C - 10 s for power circuit
        • 900 A 40 °C - 1 s for power circuit
        • 110 A 40 °C - 10 min for power circuit
        • 260 A 40 °C - 1 min for power circuit
        • 100 A - 1 s for signalling circuit
        • 120 A - 500 ms for signalling circuit
        • 140 A - 100 ms for signalling circuit
          • Associated fuse rating
          • 10 A gG for signalling circuit conforming to IEC 60947-5-1
          • 125 A gG at <= 690 V coordination type 1 for power circuit
          • 125 A gG at <= 690 V coordination type 2 for power circuit
            • Average impedance
              1.6 mOhm - Ith 80 A 50 Hz for power circuit
              [Ui] rated insulation voltage
            • power circuit: 600 V CSA certified
            • power circuit: 600 V UL certified
            • signalling circuit: 690 V conforming to IEC 60947-1
            • signalling circuit: 600 V CSA certified
            • signalling circuit: 600 V UL certified
            • power circuit: 690 V conforming to IEC 60947-4-1
              • Electrical durability
                1.4 Mcycles 80 A AC-1 at Ue <= 440 V
                Power dissipation per pole
                10.2 W AC-1
                Protective cover
                with
                Mounting support
              • plate
              • rail
                • Standards
                • CSA C22.2 No 14
                • EN 60947-4-1
                • EN 60947-5-1
                • IEC 60947-4-1
                • IEC 60947-5-1
                • UL 508
                  • Product certifications
                  • UL
                  • DNV
                  • BV
                  • CCC
                  • CSA
                  • LROS (Lloyds register of shipping)
                  • GL
                  • RINA
                  • GOST
                    • Connections - terminals
                    • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                    • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
                    • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                    • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible without cable end
                    • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible without cable end
                    • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible with cable end
                    • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible with cable end
                    • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²solid without cable end
                    • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²solid without cable end
                      • Tightening torque
                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                      • power circuit: 8 N.m - on screw clamp terminals - cable 25-35 mm² hexagonal screw head 4 mm
                      • power circuit: 5 N.m - on screw clamp terminals - cable 1-25 mm² hexagonal screw head 4 mm
                        • Operating time
                        • 4...19 ms opening
                        • 12...26 ms closing
                          • Safety reliability level
                          • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                          • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                            • Mechanical durability
                              6 Mcycles
                              Maximum operating rate
                              3600 cyc/h 60 °C
                              Coil technology
                              without built-in suppressor module
                              Control circuit voltage limits
                            • drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C)
                            • operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C)
                            • operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C)
                              • Inrush power in VA
                              • 140-140 VA 60 Hz cos phi 0.75 (at 20 °C)
                              • 160-160 VA 50 Hz cos phi 0.75 (at 20 °C)
                                • Hold-in power consumption in VA
                                • 13-13 VA 60 Hz cos phi 0.3 (at 20 °C)
                                • 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
                                  • Heat dissipation
                                    4-5 W at 50/60 Hz
                                    Auxiliary contacts type
                                  • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                  • type mirror contact 1 NC conforming to IEC 60947-4-1
                                    • Signalling circuit frequency
                                      25...400 Hz
                                      Minimum switching current
                                      5 mA for signalling circuit
                                      Minimum switching voltage
                                      17 V for signalling circuit
                                      Non-overlap time
                                    • 1.5 ms on de-energisation between NC and NO contact
                                    • 1.5 ms on energisation between NC and NO contact
                                      • Insulation resistance
                                        > 10 MOhm for signalling circuit
                                        Contact compatibility
                                        M6
                                        Compatibility code
                                        LC1D
                                        IP degree of protection
                                        IP20 front face conforming to IEC 60529
                                        Protective treatment
                                        TH conforming to IEC 60068-2-30
                                        Pollution degree
                                        3
                                        Ambient air temperature for operation
                                        -5-60 °C
                                        Ambient air temperature for storage
                                        -60-80 °C
                                        Permissible ambient air temperature around the device
                                        -40-70 °C at Uc
                                        Operating altitude
                                        3000 m without
                                        Fire resistance
                                        850 °C conforming to IEC 60695-2-1
                                        Flame retardance
                                        V1 conforming to UL 94
                                        Mechanical robustness
                                      • vibrations contactor open: 2 Gn, 5...300 Hz
                                      • vibrations contactor closed: 4 Gn, 5...300 Hz
                                      • shocks contactor closed: 15 Gn for 11 ms
                                      • shocks contactor open: 10 Gn for 11 ms
                                        • Height
                                          122 mm
                                          Width
                                          70 mm
                                          Depth
                                          120 mm
                                          Net weight
                                          1.15 kg
                                          Sustainable offer status
                                          Green Premium product
                                          REACh Regulation
                                          Free of Substances of Very High Concern above the threshold
                                          REACh free of SVHC
                                          Yes
                                          EU RoHS Directive
                                          Compliant
                                          Toxic heavy metal free
                                          Yes
                                          Mercury free
                                          Yes
                                          RoHS exemption information
                                          Yes
                                          China RoHS Regulation
                                          X
                                          Environmental Disclosure
                                          ENVPEP110205EN
                                          WEEE
                                          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                          Warranty
                                          18 months

                                          Documents & downloads

                                          hide show
                                          Filter items
                                          • All

                                          • CAD Files and Packs

                                          • Product Brochures

                                          • Technical Data Catalogues

                                          • Product Environmental

                                          • Installation Instruction

                                          • Data Bulletin

                                          • Certificates (MSDS)

                                          • Declaration of Conformity

                                          Frequently Asked Questions

                                          hide show

                                          What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                          Issue:
                                          Identifying replacement coils for tesys D non-reversing and reversing conactors

                                          Product Line:
                                          IEC Contactors and Starters

                                          Environment:
                                          Products sold and used in the United States

                                          Cause:
                                          Replacement coil is needed

                                          Resolution:
                                          DC replacement coils are not available.
                                          AC Coils are 50/60 hertz for voltages as listed below:

                                          Volts - Part Number
                                          12 ____ LXD1J7
                                          21 ____ LXD1Z7
                                          24 ____ LXD1B7
                                          32 ____ LXD1C7
                                          36 ____ LXD1CC7
                                          42 ____ LXD1D7
                                          48 ____ LXD1E7
                                          60 ____ LXD1EE7
                                          100 ___ LXD1K7 ( never brought to North America )
                                          110 ___ LXD1F7
                                          115 ___ LXD1FE7
                                          120 ___ LXD1G7
                                          127 ___ LXD1FC7
                                          200 ___ LXD1L7
                                          208 ___ LXD1LE7
                                          220 ___ LXD1M7
                                          230 ___ LXD1P7
                                          240 ___ LXD1U7
                                          277 ___ LXD1W7
                                          380 ___ LXD1Q7
                                          400 ___ LXD1V7
                                          415 ___ LXD1N7
                                          440 ___ LXD1R7
                                          480 ___ LXD1T7
                                          575 ___ LXD1SC7
                                          600 ___ LXD1X7
                                          690 ___ LXD1Y7


                                          Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                          What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                          Issue:
                                          Identifying maximum voltage of an LC1D contactor

                                          Product Line:
                                          TeSys D Contactors

                                          Environment:
                                          IEC contactors and starters used in North America

                                          Cause:
                                          n/a

                                          Resolution:
                                          IThe maximum voltage per UL and CSA is 600VAC. 
                                           

                                          Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                          Issue:
                                          Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                          Product Line: 
                                          Tesys D Contactors

                                          Environment:
                                          IEC contactors

                                          Resolution:
                                          The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                           

                                          What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                          Issue:
                                          Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                          Product Line:
                                          NEMA combination starters

                                          Environment:
                                          Products sold and used in the United States

                                          Resolution:
                                          For contactors with screw clamp terminals:
                                          stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                          stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                          solid cable: One or Two #18-8 AWG per terminal.

                                          Do the Everlink reversing contactors come with electrical interlocking?

                                          Issue:
                                          Looking for electrical interlock kit for the LC1D65A Everlnk contactors

                                          Product line:
                                          Tesys D LC1D40A, LC1D50A, LC1D65A

                                          Environment:
                                          Everlink, all voltage codes

                                          Cause:
                                          Old D2 version offered an electrical interlock kit

                                          Resolution:
                                          The current Everlink version does not offer an electrical interlock kit.  The customer can wire electrical interlocking using the normally closed contacts provided on the contactor.

                                          What is the mechanical interlock for a 4 Pole contactor LC1DT80A__?

                                          Issue:
                                          Part number for the mechanical interlock for a 4 Pole contactor LC1DT80A__?

                                          Product Line: 
                                           Contactors and Starters - IEC

                                          Environment:
                                          LC1DT80A

                                          Cause:
                                          Needs the mechanical interlock for a 4 Pole contactor LC1DT80A__.

                                          Resolution:
                                          LAD4CM

                                          What is the altitude derating for a TeSys D-Line contactor?

                                          Issue:​
                                          What is the altitude derating for a TeSys D-Line contactor?

                                          Product Line:
                                          Digest 177 Section 18 : Contactors and Starters, IEC

                                          Environment:
                                          North American Products

                                          Resolution:
                                          The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                          Voltage
                                          3500m x 0.90
                                          4000m x 0.80
                                          4500m x 0.70
                                          5000m x 0.60

                                          Current
                                          3500m x 0.92
                                          4000m x 0.90
                                          4500m x 0.88
                                          5000m x 0.86

                                          For example, an LC1D80 at 5000 meters:
                                          - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                          - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                           

                                          What is the replacement contactor for the LC1D65004F5?

                                          The new code is LC1DT80AF7 which is made to order.

                                          Looking for a LC1D50A.. with a 240v coil

                                           Part code is LC1D50AU7

                                          What does the T indicate in the LC1DT contactor catalog number?

                                          Issue:
                                          LC1DT catalog numbers

                                          Product Line:
                                          Tesys D line Contactors

                                          Environment:
                                          North American Products

                                          Resolution:
                                          The T indicates that the device is a 4 poles with all normally open poles.  4 pole units only have resistive (AC-1) power contact ratings.

                                          How Can the LC1D50AU7 Contactor be mounted?

                                          Two ways -  the LC1D50AU7 can be DIN Rail mounted and Plate mounted.

                                          See the attached datasheet for further information.

                                          What is the code for a 40A 110VAC contactor ?

                                          LC1D40AF7
                                          Show More