Key Features & Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
resistive load
Utilisation category
AC-1
Poles description
4P
Pole contact composition
4 NO
[Ue] rated operational voltage
  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current
      60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
      Control circuit type
      AC at 50 Hz
      [Uc] control circuit voltage
      12 V AC 50 Hz
      Auxiliary contact composition
      1 NO + 1 NC
      [Uimp] rated impulse withstand voltage
      6 kV conforming to IEC 60947
      Overvoltage category
      III
      [Ith] conventional free air thermal current
    • 10 A (at 60 °C) for signalling circuit
    • 60 A (at 60 °C) for power circuit
      • Irms rated making capacity
      • 140 A AC for signalling circuit conforming to IEC 60947-5-1
      • 250 A DC for signalling circuit conforming to IEC 60947-5-1
      • 800 A at 440 V for power circuit conforming to IEC 60947
        • Rated breaking capacity
          800 A at 440 V for power circuit conforming to IEC 60947
          [Icw] rated short-time withstand current
        • 320 A 40 °C - 10 s for power circuit
        • 720 A 40 °C - 1 s for power circuit
        • 72 A 40 °C - 10 min for power circuit
        • 165 A 40 °C - 1 min for power circuit
        • 100 A - 1 s for signalling circuit
        • 120 A - 500 ms for signalling circuit
        • 140 A - 100 ms for signalling circuit
          • Associated fuse rating
          • 10 A gG for signalling circuit conforming to IEC 60947-5-1
          • 80 A gG at <= 690 V coordination type 1 for power circuit
          • 80 A gG at <= 690 V coordination type 2 for power circuit
            • Average impedance
              1.6 mOhm - Ith 60 A 50 Hz for power circuit
              [Ui] rated insulation voltage
            • power circuit: 600 V CSA certified
            • power circuit: 600 V UL certified
            • signalling circuit: 690 V conforming to IEC 60947-1
            • signalling circuit: 600 V CSA certified
            • signalling circuit: 600 V UL certified
            • power circuit: 690 V conforming to IEC 60947-4-1
              • Electrical durability
                1.4 Mcycles 60 A AC-1 at Ue <= 440 V
                Power dissipation per pole
                5.8 W AC-1
                Protective cover
                with
                Mounting support
              • rail
              • plate
                • Standards
                • CSA C22.2 No 14
                • EN 60947-4-1
                • EN 60947-5-1
                • IEC 60947-4-1
                • IEC 60947-5-1
                • UL 508
                  • Product certifications
                  • GL
                  • RINA
                  • UL
                  • BV
                  • CCC
                  • LROS (Lloyds register of shipping)
                  • DNV
                  • GOST
                  • CSA
                    • Connections - terminals
                    • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                    • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible with cable end
                    • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²solid without cable end
                    • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²solid without cable end
                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                    • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
                    • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                    • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible without cable end
                    • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible without cable end
                    • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible with cable end
                      • Tightening torque
                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                      • power circuit: 8 N.m - on screw clamp terminals - cable 25-35 mm² hexagonal screw head 4 mm
                      • power circuit: 5 N.m - on screw clamp terminals - cable 1-25 mm² hexagonal screw head 4 mm
                        • Operating time
                        • 4...19 ms opening
                        • 12...26 ms closing
                          • Safety reliability level
                          • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                          • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                            • Mechanical durability
                              6 Mcycles
                              Maximum operating rate
                              3600 cyc/h 60 °C
                              Coil technology
                              without built-in suppressor module
                              Control circuit voltage limits
                            • operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C)
                            • drop-out: 0.3...0.6 Uc AC 50 Hz (at 60 °C)
                              • Inrush power in VA
                                160-160 VA 50 Hz cos phi 0.75 (at 20 °C)
                                Hold-in power consumption in VA
                                15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
                                Heat dissipation
                                4-5 W at 50 Hz
                                Auxiliary contacts type
                              • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                              • type mirror contact 1 NC conforming to IEC 60947-4-1
                                • Signalling circuit frequency
                                  25...400 Hz
                                  Minimum switching current
                                  5 mA for signalling circuit
                                  Minimum switching voltage
                                  17 V for signalling circuit
                                  Non-overlap time
                                • 1.5 ms on de-energisation between NC and NO contact
                                • 1.5 ms on energisation between NC and NO contact
                                  • Insulation resistance
                                    > 10 MOhm for signalling circuit
                                    Contact compatibility
                                    M6
                                    Compatibility code
                                    LC1D
                                    IP degree of protection
                                    IP20 front face conforming to IEC 60529
                                    Protective treatment
                                    TH conforming to IEC 60068-2-30
                                    Pollution degree
                                    3
                                    Ambient air temperature for operation
                                    -5-60 °C
                                    Ambient air temperature for storage
                                    -60-80 °C
                                    Permissible ambient air temperature around the device
                                    -40-70 °C at Uc
                                    Operating altitude
                                    3000 m without
                                    Fire resistance
                                    850 °C conforming to IEC 60695-2-1
                                    Flame retardance
                                    V1 conforming to UL 94
                                    Mechanical robustness
                                  • vibrations contactor open: 2 Gn, 5...300 Hz
                                  • vibrations contactor closed: 4 Gn, 5...300 Hz
                                  • shocks contactor closed: 15 Gn for 11 ms
                                  • shocks contactor open: 10 Gn for 11 ms
                                    • Height
                                      122 mm
                                      Width
                                      70 mm
                                      Depth
                                      120 mm
                                      Net weight
                                      1.09 kg
                                      REACh Regulation
                                      Reference contains Substances of Very High Concern above the threshold
                                      EU RoHS Directive
                                      Under investigation
                                      Circularity Profile
                                      N/A
                                      CALIFORNIA PROPOSITION 65
                                      WARNING: Cancer - www.P65Warnings.ca.gov
                                      Warranty
                                      18 months

                                      Documents & downloads

                                      hide show
                                      Filter items
                                      • All

                                      • CAD Files and Packs

                                      • Product Brochures

                                      • Movies

                                      • Catalog Page

                                      • Technical Data Catalogues

                                      • Technical Leaflet

                                      • Data Bulletin

                                      • Installation Instruction

                                      • End of Life Manual

                                      • Product Environmental

                                      • Handout

                                      • Operating Manuals

                                      • Application Solutions

                                      • Certificates (MSDS)

                                      • Declaration of Conformity

                                      • White Paper

                                      • Marine Certificate

                                      • eTechPub

                                      • Software - Released