TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 65A, 24VDC, Standard Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 65A, 24VDC, Standard Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 65A, 24VDC, Standard Coil

Item Number: LC1D65ABD

Retail
$2,440.58
RRP (Inc. GST)

Product Dimensions

Width icon

Width55 mm

Height icon

Height122 mm

Depth icon

Depth120 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current

    • 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
      • Electrical durability

      • 0.5 Mcycles 80 A AC-1 at Ue <= 440 V
      • 1.45 Mcycles 65 A AC-3 at Ue <= 440 V
        • Mounting support

        • plate
        • rail
          • Standards

          • CSA C22.2 No 14
          • EN 60947-4-1
          • EN 60947-5-1
          • IEC 60947-4-1
          • IEC 60947-5-1
          • UL 508
            • Product certifications

            • GOST
            • UL
            • CCC
            • CSA
              • Connections - terminals

              • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
              • power circuit: screw connection 1 cable(s) 1-35 mm²flexible without cable end
              • power circuit: screw connection 2 cable(s) 1-25 mm²flexible without cable end
              • power circuit: screw connection 1 cable(s) 1-35 mm²flexible with cable end
              • power circuit: screw connection 2 cable(s) 1-25 mm²flexible with cable end
              • power circuit: screw connection 1 cable(s) 1-35 mm²solid without cable end
              • power circuit: screw connection 2 cable(s) 1-25 mm²solid without cable end
                • Mechanical durability

                  10 Mcycles

                  Insulation resistance

                  > 10 MOhm for signalling circuit

                  IP degree of protection

                  IP20 front face conforming to IEC 60529

                  Ambient air temperature for storage

                  -60-80 °C

                  Height

                  122 mm

                  Width

                  55 mm

                  Depth

                  120 mm

                  Net weight

                  0.935 kg

                  REACh free of SVHC

                  Yes

                  EU RoHS Directive

                  Compliant

                  Toxic heavy metal free

                  Yes

                  Mercury free

                  Yes

                  RoHS exemption information

                  Yes

                  China RoHS Regulation

                   Pro-active China RoHS declaration (out of China RoHS legal scope)

                  Environmental Disclosure

                  ENVPEP1503009EN

                  Circularity Profile

                  ENVEOLI1503009EN

                  Others

                  Product name

                  TeSys D

                  Device short name

                  LC1D

                  Contactor application

                • motor control
                • resistive load
                  • Utilisation category

                  • AC-3
                  • AC-4
                  • AC-1
                    • Poles description

                      3P

                      Pole contact composition

                      3 NO

                      Motor power kW

                    • 11 kW at 400 V AC 50/60 Hz (AC-4)
                    • 18.5 kW at 220...230 V AC 50/60 Hz (AC-3)
                    • 30 kW at 380...400 V AC 50/60 Hz (AC-3)
                    • 37 kW at 500 V AC 50/60 Hz (AC-3)
                    • 37 kW at 660...690 V AC 50/60 Hz (AC-3)
                      • Motor power hp

                      • 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors
                      • 5 hp at 115 V AC 50/60 Hz for 1 phase motors
                      • 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors
                      • 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors
                      • 20 hp at 230/240 V AC 50/60 Hz for 3 phases motors
                      • 50 hp at 575/600 V AC 50/60 Hz for 3 phases motors
                        • Control circuit type

                          DC standard

                          [Uc] control circuit voltage

                          24 V DC

                          Auxiliary contact composition

                          1 NO + 1 NC

                          [Uimp] rated impulse withstand voltage

                          6 kV conforming to IEC 60947

                          Overvoltage category

                          III

                          [Ith] conventional free air thermal current

                        • 10 A (at 60 °C) for signalling circuit
                        • 80 A (at 60 °C) for power circuit
                          • Irms rated making capacity

                          • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                          • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                          • 1000 A at 440 V for power circuit conforming to IEC 60947
                            • Rated breaking capacity

                              1000 A at 440 V for power circuit conforming to IEC 60947

                              [Icw] rated short-time withstand current

                            • 520 A 40 °C - 10 s for power circuit
                            • 900 A 40 °C - 1 s for power circuit
                            • 110 A 40 °C - 10 min for power circuit
                            • 260 A 40 °C - 1 min for power circuit
                            • 100 A - 1 s for signalling circuit
                            • 120 A - 500 ms for signalling circuit
                            • 140 A - 100 ms for signalling circuit
                              • Associated fuse rating

                              • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                              • 125 A gG at <= 690 V coordination type 1 for power circuit
                              • 125 A gG at <= 690 V coordination type 2 for power circuit
                                • Average impedance

                                  1.5 mOhm - Ith 80 A 50 Hz for power circuit

                                  [Ui] rated insulation voltage

                                • power circuit: 600 V CSA certified
                                • power circuit: 600 V UL certified
                                • signalling circuit: 690 V conforming to IEC 60947-1
                                • signalling circuit: 600 V CSA certified
                                • signalling circuit: 600 V UL certified
                                • power circuit: 690 V conforming to IEC 60947-4-1
                                  • Power dissipation per pole

                                  • 9.6 W AC-1
                                  • 6.3 W AC-3
                                    • Protective cover

                                      with

                                      Tightening torque

                                    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                    • power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm
                                    • power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm
                                      • Operating time

                                      • 42.5...57.5 ms closing
                                      • 16...24 ms opening
                                        • Safety reliability level

                                        • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                        • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                          • Maximum operating rate

                                            3600 cyc/h 60 °C

                                            Coil technology

                                            built-in bidirectional peak limiting diode suppressor

                                            Time constant

                                            34 ms

                                            Inrush power in W

                                            19-19 W (at 20 °C)

                                            Hold-in power consumption in W

                                            7.4-7.4 W at 20 °C

                                            Auxiliary contacts type

                                          • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                          • type mirror contact 1 NC conforming to IEC 60947-4-1
                                            • Signalling circuit frequency

                                              25...400 Hz

                                              Minimum switching current

                                              5 mA for signalling circuit

                                              Minimum switching voltage

                                              17 V for signalling circuit

                                              Non-overlap time

                                            • 1.5 ms on de-energisation between NC and NO contact
                                            • 1.5 ms on energisation between NC and NO contact
                                              • Contact compatibility

                                                M4

                                                Compatibility code

                                                LC1D

                                                Power range

                                              • 15-25 kW at 200-240 V 3 phases
                                              • 30-50 kW at 380-440 V 3 phases
                                              • 30-50 kW at 480-500 V 3 phases
                                                • Motor starter type

                                                  direct on-line contactor

                                                  Contactor coil voltage

                                                  24 V DC standard

                                                  Protective treatment

                                                  TH conforming to IEC 60068-2-30

                                                  Pollution degree

                                                  3

                                                  Operating altitude

                                                  3000 m without derating

                                                  Fire resistance

                                                  850 °C conforming to IEC 60695-2-1

                                                  Flame retardance

                                                  V1 conforming to UL 94

                                                  Mechanical robustness

                                                • vibrations contactor open: 2 Gn, 5...300 Hz
                                                • vibrations contactor closed: 4 Gn, 5...300 Hz
                                                • shocks contactor closed: 15 Gn for 11 ms
                                                • shocks contactor open: 10 Gn for 11 ms
                                                  • Unit Type of Package 1

                                                    PCE

                                                    Number of Units in Package 1

                                                    1

                                                    Package 1 Weight

                                                    1.004 kg

                                                    Package 1 Height

                                                    6.2 cm

                                                    Package 1 width

                                                    13.4 cm

                                                    Package 1 Length

                                                    15.2 cm

                                                    Unit Type of Package 2

                                                    S02

                                                    Number of Units in Package 2

                                                    10

                                                    Package 2 Weight

                                                    10.39 kg

                                                    Package 2 Height

                                                    15 cm

                                                    Package 2 width

                                                    30 cm

                                                    Package 2 Length

                                                    40 cm

                                                    Unit Type of Package 3

                                                    P06

                                                    Number of Units in Package 3

                                                    160

                                                    Package 3 Weight

                                                    174.74 kg

                                                    Package 3 Height

                                                    77 cm

                                                    Package 3 width

                                                    80 cm

                                                    Package 3 Length

                                                    60 cm

                                                    WEEE

                                                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                                    PVC free

                                                    Yes
                                                    Show all specifications

                                                    Documents & downloads

                                                    hide show
                                                    Filter items
                                                    • All

                                                    • CAD Files and Packs

                                                    • Product Brochures

                                                    • Technical Data Catalogues

                                                    • Installation Instruction

                                                    • End of Life Manual

                                                    • Product Environmental

                                                    • Data Bulletin

                                                    • Certificates (MSDS)

                                                    • eTechPub

                                                    • Declaration of Conformity

                                                    Frequently Asked Questions

                                                    hide show

                                                    What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                    Issue:
                                                    Identifying maximum voltage of an LC1D contactor

                                                    Product Line:
                                                    TeSys D Contactors

                                                    Environment:
                                                    IEC contactors and starters used in North America

                                                    Cause:
                                                    n/a

                                                    Resolution:
                                                    IThe maximum voltage per UL and CSA is 600VAC. 
                                                     

                                                    What is the altitude derating for a TeSys D-Line contactor?

                                                    Issue:​
                                                    What is the altitude derating for a TeSys D-Line contactor?

                                                    Product Line:
                                                    Digest 177 Section 18 : Contactors and Starters, IEC

                                                    Environment:
                                                    North American Products

                                                    Resolution:
                                                    The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                                    Voltage
                                                    3500m x 0.90
                                                    4000m x 0.80
                                                    4500m x 0.70
                                                    5000m x 0.60

                                                    Current
                                                    3500m x 0.92
                                                    4000m x 0.90
                                                    4500m x 0.88
                                                    5000m x 0.86

                                                    For example, an LC1D80 at 5000 meters:
                                                    - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                                    - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                                     

                                                    What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                                    Issue:
                                                    Identifying power terminal lug data for the D2 style contactors

                                                    Product Line:
                                                    Tesys D line contactors

                                                    Environment:
                                                    Products sold and used in the United States

                                                    Cause:
                                                    Power terminal lug data required

                                                    Resolution:
                                                    For contactors with screw clamp terminals:
                                                    stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                                    stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                                    solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                                    What replaces LC1D50BD

                                                    Replacement LC1D50ABD

                                                    Do the Everlink reversing contactors come with electrical interlocking?

                                                    Issue:
                                                    Looking for electrical interlock kit for the LC1D65A Everlnk contactors

                                                    Product line:
                                                    Tesys D LC1D40A, LC1D50A, LC1D65A

                                                    Environment:
                                                    Everlink, all voltage codes

                                                    Cause:
                                                    Old D2 version offered an electrical interlock kit

                                                    Resolution:
                                                    The current Everlink version does not offer an electrical interlock kit.  The customer can wire electrical interlocking using the normally closed contacts provided on the contactor.

                                                    Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                                    Issue:
                                                    Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                                    Product Line: 
                                                    Tesys D Contactors

                                                    Environment:
                                                    IEC contactors

                                                    Resolution:
                                                    The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                                     

                                                    What is the difference between a LC1D65A3U7 and LC1D65AU7?

                                                    The difference between the LC1D65A3U7 and the LC1D65AU7 is that the Control connections are spring terminals for the LC1D65A3U7 and screw clamp terminals for the LC1D65AU7
                                                    see data sheets for comparrisons...
                                                    https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=lc1d65a3u7

                                                    https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=lc1d65au7
                                                    User-added image.................User-added image

                                                    Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                                                    Issue:
                                                    Mounting adaptor for GV2 and LC1D contactor

                                                    Product Line:
                                                    Motor Starters and Protectors

                                                    Environment:
                                                    TeSys GV Manual Starter and Protectors
                                                    Tesys D Contactors
                                                     
                                                    Resolution:
                                                    The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                                                    What is the replacement AC coil for LC1D/LC2D40, D50, D65, D80, and D95?

                                                    Issue:
                                                    AC Coil information for LC1D/LC2D40, D50, D65, D80, and D95

                                                    Product Line:
                                                    Tesys D Replacement Parts

                                                    Environment:
                                                    TeSys™ D AC Coils

                                                    Resolution:

                                                    Does LC1D65AB7 3P (3 NO) TeSys Model D contactor have a normally opened and normally closed auxiliary contact?

                                                    How many wires can you install on the Power poles for the LC1D65A contactor?

                                                     Issue:
                                                    How many wires can you install on the Power poles for the LC1D65A contactor?

                                                    Product line:
                                                    Tesys D, Everlink

                                                    Environment:
                                                    LC1D40A LC1D50A LC1D65A

                                                    Cause:
                                                    Documentation not found

                                                    Resolution:
                                                    The LC1D40A to LC1D65A Everlink version contactors can use 2 power cables per phase.  1x AWG 16 to AWG 4 plus 1x AWG 16 to AWG 2. 

                                                    Instruction bulletin attached.

                                                    LC1D6511 contactor with 220V coil - NZ equivalent?

                                                    LC1D65A contactor with a U7 240VAC coil is the closest.
                                                    Show More