TeSys D Contactor, 4P(2 NO + 2 NC), AC-1, <= 440V, 80A, 42VAC, 50/60 Hz Coil

TeSys D Contactor, 4P(2 NO + 2 NC), AC-1, <= 440V, 80A, 42VAC, 50/60 Hz Coil

TeSys D Contactor, 4P(2 NO + 2 NC), AC-1, <= 440V, 80A, 42VAC, 50/60 Hz Coil

Item Number: LC1D65008D7

Retail
$2,378.28
RRP (Inc. GST)

Product Dimensions

Width icon

Width85 mm

Height icon

Height127 mm

Depth icon

Depth125 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current

      80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

      Electrical durability

      1.4 Mcycles 80 A AC-1 at Ue <= 440 V

      Mounting support

    • plate
    • rail
      • Standards

      • CSA C22.2 No 14
      • EN 60947-4-1
      • EN 60947-5-1
      • IEC 60947-4-1
      • IEC 60947-5-1
      • UL 508
        • Product certifications

        • CCC
        • UL
        • CSA
        • BV
        • GL
        • RINA
        • DNV
        • GOST
        • LROS (Lloyds register of shipping)
          • Connections - terminals

          • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
          • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
          • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
          • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
          • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
          • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
          • power circuit: screw clamp terminals 1 cable(s) 1-35 mm²flexible without cable end
          • power circuit: screw clamp terminals 2 cable(s) 1-25 mm²flexible without cable end
          • power circuit: screw clamp terminals 1 cable(s) 1-35 mm²flexible with cable end
          • power circuit: screw clamp terminals 2 cable(s) 1-25 mm²flexible with cable end
          • power circuit: screw clamp terminals 1 cable(s) 1-35 mm²solid without cable end
          • power circuit: screw clamp terminals 2 cable(s) 1-25 mm²solid without cable end
            • Mechanical durability

              6 Mcycles

              IP degree of protection

              IP20 front face conforming to IEC 60529

              Ambient air temperature for storage

              -60-80 °C

              Height

              127 mm

              Width

              85 mm

              Depth

              125 mm

              Net weight

              1.45 kg

              REACh free of SVHC

              Yes

              EU RoHS Directive

              Compliant

              Toxic heavy metal free

              Yes

              Mercury free

              Yes

              RoHS exemption information

              Yes

              China RoHS Regulation

               Pro-active China RoHS declaration (out of China RoHS legal scope)

              Environmental Disclosure

              ENVPEP1503009EN

              Circularity Profile

              ENVEOLI1503009EN

              California proposition 65

              WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov

              Others

              Product name

              TeSys D

              Device short name

              LC1D

              Contactor application

              resistive load

              Utilisation category

              AC-1

              Poles description

              4P

              Pole contact composition

              2 NO + 2 NC

              Control circuit type

              AC at 50/60 Hz

              [Uc] control circuit voltage

              42 V AC 50/60 Hz

              [Uimp] rated impulse withstand voltage

              6 kV conforming to IEC 60947

              Overvoltage category

              III

              [Ith] conventional free air thermal current

              80 A (at 60 °C) for power circuit

              Irms rated making capacity

              1000 A at 440 V for power circuit conforming to IEC 60947

              Rated breaking capacity

              1000 A at 440 V for power circuit conforming to IEC 60947

              [Icw] rated short-time withstand current

            • 520 A 40 °C - 10 s for power circuit
            • 900 A 40 °C - 1 s for power circuit
            • 110 A 40 °C - 10 min for power circuit
            • 260 A 40 °C - 1 min for power circuit
              • Associated fuse rating

              • 125 A gG at <= 690 V coordination type 1 for power circuit
              • 125 A gG at <= 690 V coordination type 2 for power circuit
                • Average impedance

                  1.5 mOhm - Ith 80 A 50 Hz for power circuit

                  [Ui] rated insulation voltage

                • power circuit: 600 V CSA certified
                • power circuit: 600 V UL certified
                • power circuit: 690 V conforming to IEC 60947-4-1
                  • Power dissipation per pole

                    9.6 W AC-1

                    Protective cover

                    without

                    Tightening torque

                  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                  • power circuit: 8 N.m - on screw clamp terminals - cable 25-35 mm² hexagonal screw head 4 mm
                  • power circuit: 5 N.m - on screw clamp terminals - cable 1-25 mm² hexagonal screw head 4 mm
                    • Operating time

                    • 4...19 ms opening
                    • 12...26 ms closing
                      • Safety reliability level

                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                        • Maximum operating rate

                          3600 cyc/h 60 °C

                          Coil technology

                          without built-in suppressor module

                          Inrush power in VA

                        • 140-140 VA 60 Hz cos phi 0.75 (at 20 °C)
                        • 160-160 VA 50 Hz cos phi 0.75 (at 20 °C)
                          • Hold-in power consumption in VA

                          • 13-13 VA 60 Hz cos phi 0.3 (at 20 °C)
                          • 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
                            • Heat dissipation

                              4-5 W at 50/60 Hz

                              Contact compatibility

                              M1

                              Compatibility code

                              LC1D

                              Protective treatment

                              TH conforming to IEC 60068-2-30

                              Pollution degree

                              3

                              Operating altitude

                              3000 m without derating

                              Fire resistance

                              850 °C conforming to IEC 60695-2-1

                              Flame retardance

                              V1 conforming to UL 94

                              Mechanical robustness

                            • vibrations contactor open: 2 Gn, 5...300 Hz
                            • vibrations contactor closed: 4 Gn, 5...300 Hz
                            • shocks contactor closed: 15 Gn for 11 ms
                            • shocks contactor open: 10 Gn for 11 ms
                              • Unit Type of Package 1

                                PCE

                                Number of Units in Package 1

                                1

                                Package 1 Weight

                                1.5 kg

                                Package 1 Height

                                9.1 cm

                                Package 1 width

                                12.6 cm

                                Package 1 Length

                                13.2 cm

                                WEEE

                                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                PVC free

                                Yes
                                Show all specifications

                                Documents & downloads

                                hide show
                                Filter items
                                • All

                                • Product Brochures

                                • Technical Data Catalogues

                                • End of Life Manual

                                • Product Environmental

                                • Data Bulletin

                                • Certificates (MSDS)

                                • Declaration of Conformity

                                Frequently Asked Questions

                                hide show

                                What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                Issue:
                                Identifying power terminal lug data for the D2 style contactors

                                Product Line:
                                Tesys D line contactors

                                Environment:
                                Products sold and used in the United States

                                Cause:
                                Power terminal lug data required

                                Resolution:
                                For contactors with screw clamp terminals:
                                stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                Issue:
                                Identifying maximum voltage of an LC1D contactor

                                Product Line:
                                TeSys D Contactors

                                Environment:
                                IEC contactors and starters used in North America

                                Cause:
                                n/a

                                Resolution:
                                IThe maximum voltage per UL and CSA is 600VAC. 
                                 

                                Are the D-Line contactors rated to break DC voltages?

                                Issue: 
                                Can the TeSys D line be used to control DC loads? 

                                Product Line:
                                Tesys D contactors

                                Environment:
                                Products sold and used in the United States
                                 
                                Cause:
                                 DC power circuit
                                 
                                Resolution:
                                 
                                Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                Devices are suitable but not UL Listed for DC applications.

                                More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                 

                                Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

                                Issue:
                                Auxiliary contact modules for the LC1D and LC2D contactors

                                Product Line: 
                                Contactor and Starters - IEC

                                Environment:
                                North American Products

                                Resolution:
                                Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
                                Front Mounting; maximum of 1 block per contactor:

                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                --1-----------1---------LADN11-----------LA1DN11
                                --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
                                --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
                                --2-----------0---------LADN20-----------LA1DN20
                                --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
                                --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
                                --0-----------2---------LADN02-----------LA1DN02
                                --2-----------2---------LADN22-----------LA1DN22
                                --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
                                --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
                                --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
                                --3-----------1---------LADN31------------LA1DN31
                                --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
                                --1-----------3---------LADN13------------LA1DN13
                                --4-----------0---------LADN40------------LA1DN40
                                --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
                                --0-----------4---------LADN04------------LA1DN04




                                Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                --1-----------0--------LADN10----------LA1DN10
                                --0-----------1--------LADN01----------LA1DN01

                                Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
                                (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                --1-----------1--------LAD8N11----------LA8DN11
                                --2-----------0--------LAD8N20----------LA8DN20
                                --0-----------2--------LAD8N02----------N/A

                                Footnotes:
                                {1} EN50 012 Machine Tool Terminal Markings
                                {2} (2) NO Sealed Dust Tight Contacts
                                {3} Gold Flash Contacts
                                {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
                                {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
                                {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts

                                What is the color scheme of the Tesys D-Line contactors?

                                Issue:
                                Looking for different color scheme of the Tesys D-Line contactors.

                                Product Line:
                                Tesys D Contactors

                                Environment:
                                LC1D contactors

                                Resolution:
                                Beige and dark gray.
                                 

                                What are the stand alone short circuit current ratings on the LC1D** contactors?

                                Issue:
                                Tesys D SCCR

                                Product Line:
                                Contactors and Overload Relays

                                Environment:
                                TeSys™ D Contactors and Overload Relays
                                 
                                Resolution:
                                The contactors have a stand alone withstand rating that has been established by UL and is based on the maximum horsepower rating for a given device. However, only combination type starters are supplied with short circuit protective devices having a short circuit current rating.

                                They are as follows:
                                Horsepower SCCR (A)

                                0 thru 1 1,000
                                1 thru 50 5,000
                                51 thru 200 10,000
                                201 thru 400 18,000
                                401 thru 600 30,000
                                601 thru 900 42,000
                                901 thru 1600 85,000
                                1601+ 100,000

                                What is the replacement AC coil for LC1D/LC2D40, D50, D65, D80, and D95?

                                Issue:
                                AC Coil information for LC1D/LC2D40, D50, D65, D80, and D95

                                Product Line:
                                Tesys D Replacement Parts

                                Environment:
                                TeSys™ D AC Coils

                                Resolution:

                                Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

                                Issue:
                                Can new accessories be used on older style contactors

                                Product Line:
                                IEC contactors and starters

                                Environment:
                                Products sold and used in the United States

                                Cause:
                                Identifying product compatibility

                                Resolution:
                                Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


                                 

                                What is the part cod for a contactor 4P 2N/C 2N/O 48Vac coil

                                 The part code is LC1D40008E7

                                Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                Issue:
                                Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                Product Line: 
                                Tesys D Contactors

                                Environment:
                                IEC contactors

                                Resolution:
                                The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                 

                                What is the dimensions for a LC1K09008N7

                                 Dimensions 45mm(W) x 50mm(H) x 57mm(D).

                                What is the difference between the LC1D1506N7 and the LC1D150N7?

                                The LC1D1506N7 can accept 5X25mm Bars aswell as Lugs or ring terminals. The LC1D150N7 only accepts cable lugs upto 120mm2.
                                Show More