TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 50A, 60VDC, Standard Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 50A, 60VDC, Standard Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 50A, 60VDC, Standard Coil

Item Number: LC1D50AND

Retail
$2,365.91
RRP (Inc. GST)

Product Dimensions

Width icon

Width55 mm

Height icon

Height122 mm

Depth icon

Depth120 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current

    • 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
      • Electrical durability

      • 1.45 Mcycles 50 A AC-3 at Ue <= 440 V
      • 0.5 Mcycles 80 A AC-1 at Ue <= 440 V
        • Mounting support

        • rail
        • plate
          • Standards

          • CSA C22.2 No 14
          • EN 60947-4-1
          • EN 60947-5-1
          • IEC 60947-4-1
          • IEC 60947-5-1
          • UL 508
            • Product certifications

            • RINA
            • CCC
            • GL
            • GOST
            • UL
            • CSA
            • LROS (Lloyds register of shipping)
            • DNV
            • BV
              • Connections - terminals

              • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
              • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible without cable end
              • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible without cable end
              • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible with cable end
              • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible with cable end
              • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²solid without cable end
              • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²solid without cable end
                • Mechanical durability

                  10 Mcycles

                  Insulation resistance

                  > 10 MOhm for signalling circuit

                  IP degree of protection

                  IP20 front face conforming to IEC 60529

                  Ambient air temperature for storage

                  -60-80 °C

                  Height

                  122 mm

                  Width

                  55 mm

                  Depth

                  120 mm

                  Net weight

                  0.93 kg

                  REACh free of SVHC

                  Yes

                  EU RoHS Directive

                  Compliant

                  Toxic heavy metal free

                  Yes

                  Mercury free

                  Yes

                  RoHS exemption information

                  Yes

                  China RoHS Regulation

                   Pro-active China RoHS declaration (out of China RoHS legal scope)

                  Environmental Disclosure

                  ENVPEP1503009EN

                  Circularity Profile

                  ENVEOLI1503009EN

                  California proposition 65

                  WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov

                  Others

                  Product name

                  TeSys D

                  Device short name

                  LC1D

                  Contactor application

                • motor control
                • resistive load
                  • Utilisation category

                  • AC-4
                  • AC-1
                  • AC-3
                    • Poles description

                      3P

                      Pole contact composition

                      3 NO

                      Motor power kW

                    • 15 kW at 220...230 V AC 50/60 Hz (AC-3)
                    • 22 kW at 380...400 V AC 50/60 Hz (AC-3)
                    • 30 kW at 500 V AC 50/60 Hz (AC-3)
                    • 33 kW at 660...690 V AC 50/60 Hz (AC-3)
                    • 25 kW at 415 V AC 50/60 Hz (AC-3)
                    • 30 kW at 440 V AC 50/60 Hz (AC-3)
                    • 11 kW at 400 V AC 50/60 Hz (AC-4)
                      • Motor power hp

                      • 3 hp at 115 V AC 50/60 Hz for 1 phase motors
                      • 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
                      • 15 hp at 200/208 V AC 50/60 Hz for 3 phases motors
                      • 15 hp at 230/240 V AC 50/60 Hz for 3 phases motors
                      • 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors
                      • 40 hp at 575/600 V AC 50/60 Hz for 3 phases motors
                        • Control circuit type

                          DC standard

                          [Uc] control circuit voltage

                          60 V DC

                          Auxiliary contact composition

                          1 NO + 1 NC

                          [Uimp] rated impulse withstand voltage

                          6 kV conforming to IEC 60947

                          Overvoltage category

                          III

                          [Ith] conventional free air thermal current

                        • 10 A (at 60 °C) for signalling circuit
                        • 80 A (at 60 °C) for power circuit
                          • Irms rated making capacity

                          • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                          • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                          • 900 A at 440 V for power circuit conforming to IEC 60947
                            • Rated breaking capacity

                              900 A at 440 V for power circuit conforming to IEC 60947

                              [Icw] rated short-time withstand current

                            • 400 A 40 °C - 10 s for power circuit
                            • 810 A 40 °C - 1 s for power circuit
                            • 84 A 40 °C - 10 min for power circuit
                            • 208 A 40 °C - 1 min for power circuit
                            • 100 A - 1 s for signalling circuit
                            • 120 A - 500 ms for signalling circuit
                            • 140 A - 100 ms for signalling circuit
                              • Associated fuse rating

                              • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                              • 100 A gG at <= 690 V coordination type 1 for power circuit
                              • 100 A gG at <= 690 V coordination type 2 for power circuit
                                • Average impedance

                                  1.5 mOhm - Ith 80 A 50 Hz for power circuit

                                  [Ui] rated insulation voltage

                                • power circuit: 600 V CSA certified
                                • power circuit: 600 V UL certified
                                • signalling circuit: 690 V conforming to IEC 60947-1
                                • signalling circuit: 600 V CSA certified
                                • signalling circuit: 600 V UL certified
                                • power circuit: 690 V conforming to IEC 60947-4-1
                                  • Power dissipation per pole

                                  • 3.7 W AC-3
                                  • 9.6 W AC-1
                                    • Protective cover

                                      with

                                      Tightening torque

                                    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                    • power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm
                                    • power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm
                                      • Operating time

                                      • 42.5...57.5 ms closing
                                      • 16...24 ms opening
                                        • Safety reliability level

                                        • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                        • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                          • Maximum operating rate

                                            3600 cyc/h 60 °C

                                            Coil technology

                                            built-in bidirectional peak limiting diode suppressor

                                            Time constant

                                            34 ms

                                            Inrush power in W

                                            19-19 W (at 20 °C)

                                            Hold-in power consumption in W

                                            7.4-7.4 W at 20 °C

                                            Auxiliary contacts type

                                          • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                          • type mirror contact 1 NC conforming to IEC 60947-4-1
                                            • Signalling circuit frequency

                                              25...400 Hz

                                              Minimum switching current

                                              5 mA for signalling circuit

                                              Minimum switching voltage

                                              17 V for signalling circuit

                                              Non-overlap time

                                            • 1.5 ms on de-energisation between NC and NO contact
                                            • 1.5 ms on energisation between NC and NO contact
                                              • Contact compatibility

                                                M4

                                                Compatibility code

                                                LC1D

                                                Protective treatment

                                                TH conforming to IEC 60068-2-30

                                                Pollution degree

                                                3

                                                Operating altitude

                                                3000 m without derating

                                                Fire resistance

                                                850 °C conforming to IEC 60695-2-1

                                                Flame retardance

                                                V1 conforming to UL 94

                                                Mechanical robustness

                                              • vibrations contactor open: 2 Gn, 5...300 Hz
                                              • vibrations contactor closed: 4 Gn, 5...300 Hz
                                              • shocks contactor closed: 15 Gn for 11 ms
                                              • shocks contactor open: 10 Gn for 11 ms
                                                • Unit Type of Package 1

                                                  PCE

                                                  Number of Units in Package 1

                                                  1

                                                  Package 1 Weight

                                                  850 g

                                                  Package 1 Height

                                                  6 cm

                                                  Package 1 width

                                                  14 cm

                                                  Package 1 Length

                                                  15 cm

                                                  WEEE

                                                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                                  PVC free

                                                  Yes
                                                  Show all specifications

                                                  Documents & downloads

                                                  hide show
                                                  Filter items
                                                  • All

                                                  • CAD Files and Packs

                                                  • Product Brochures

                                                  • Technical Data Catalogues

                                                  • Installation Instruction

                                                  • Product Environmental

                                                  • End of Life Manual

                                                  • Data Bulletin

                                                  • Certificates (MSDS)

                                                  • Declaration of Conformity

                                                  Frequently Asked Questions

                                                  hide show

                                                  What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                  Issue:
                                                  Identifying maximum voltage of an LC1D contactor

                                                  Product Line:
                                                  TeSys D Contactors

                                                  Environment:
                                                  IEC contactors and starters used in North America

                                                  Cause:
                                                  n/a

                                                  Resolution:
                                                  IThe maximum voltage per UL and CSA is 600VAC. 
                                                   

                                                  What is the altitude derating for a TeSys D-Line contactor?

                                                  Issue:​
                                                  What is the altitude derating for a TeSys D-Line contactor?

                                                  Product Line:
                                                  Digest 177 Section 18 : Contactors and Starters, IEC

                                                  Environment:
                                                  North American Products

                                                  Resolution:
                                                  The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                                  Voltage
                                                  3500m x 0.90
                                                  4000m x 0.80
                                                  4500m x 0.70
                                                  5000m x 0.60

                                                  Current
                                                  3500m x 0.92
                                                  4000m x 0.90
                                                  4500m x 0.88
                                                  5000m x 0.86

                                                  For example, an LC1D80 at 5000 meters:
                                                  - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                                  - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                                   

                                                  What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                                  Issue:
                                                  Identifying power terminal lug data for the D2 style contactors

                                                  Product Line:
                                                  Tesys D line contactors

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Power terminal lug data required

                                                  Resolution:
                                                  For contactors with screw clamp terminals:
                                                  stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                                  stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                                  solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                                  What replaces LC1D50BD

                                                  Replacement LC1D50ABD

                                                  Looking for a LC1D50A.. with a 240v coil

                                                   Part code is LC1D50AU7

                                                  Do the Everlink reversing contactors come with electrical interlocking?

                                                  Issue:
                                                  Looking for electrical interlock kit for the LC1D65A Everlnk contactors

                                                  Product line:
                                                  Tesys D LC1D40A, LC1D50A, LC1D65A

                                                  Environment:
                                                  Everlink, all voltage codes

                                                  Cause:
                                                  Old D2 version offered an electrical interlock kit

                                                  Resolution:
                                                  The current Everlink version does not offer an electrical interlock kit.  The customer can wire electrical interlocking using the normally closed contacts provided on the contactor.

                                                  What is difference between LC1D50U7 and LC1D50AU7?

                                                  Following are the differences between the LC1D50U7 and the LC1D50AU7:

                                                  LC1D50AU7 has everlink terminals.
                                                  LC1D50AU7....is slightly larger case and accommodate LRD3XX overloads
                                                  Whereas
                                                  LC1D50U7 contactors accommodate LRD33XX overloads.

                                                   

                                                  What is the difference between the LC1D1506N7 and the LC1D150N7?

                                                  The LC1D1506N7 can accept 5X25mm Bars aswell as Lugs or ring terminals. The LC1D150N7 only accepts cable lugs upto 120mm2.

                                                  How Can the LC1D50AU7 Contactor be mounted?

                                                  Two ways -  the LC1D50AU7 can be DIN Rail mounted and Plate mounted.

                                                  See the attached datasheet for further information.

                                                  What is the Overload for LC1D50AU7 range is 37..50 Amps?

                                                  LRD350

                                                  What mechanical interlock should I use with the LC1D50A••?

                                                  The mechanical interlock LAD4CM is the correct one for use with the LC1D50A••.

                                                  See attached datasheet for futher information on the LAD4CM.

                                                  What is the part code for a 24V AC coil for the LC1D50A?

                                                  LXD3B7
                                                   
                                                  Show More