TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 150A, 220VAC, 50/60 Hz Coil

Catalogue Number: LC1D1506M7
LC1D1506E7S5 TeSys D size 5
TeSys contactor LC1-D
TeSys contactor LC1-D
TeSys contactor LC1-D
LC1D1506E7S5 TeSys D size 5
TeSys contactor LC1-D
TeSys contactor LC1-D
TeSys contactor LC1-D
Retail
$3,383.55
RRP (Inc. GST)

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
  • motor control
  • resistive load
    • Utilisation category
    • AC-3
    • AC-4
    • AC-1
      • Poles description
        3P
        Pole contact composition
        3 NO
        [Ue] rated operational voltage
      • power circuit: <= 1000 V AC 25...400 Hz
      • power circuit: <= 300 V DC
        • [Ie] rated operational current
        • 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
        • 150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
          • Motor power kW
          • 40 kW at 220...230 V AC 50/60 Hz (AC-3)
          • 75 kW at 380...400 V AC 50/60 Hz (AC-3)
          • 80 kW at 415...440 V AC 50/60 Hz (AC-3)
          • 90 kW at 500 V AC 50/60 Hz (AC-3)
          • 100 kW at 660...690 V AC 50/60 Hz (AC-3)
          • 75 kW at 1000 V AC 50/60 Hz (AC-3)
          • 22 kW at 400 V AC 50/60 Hz (AC-4)
            • Motor power hp
            • 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors
            • 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors
            • 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors
            • 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors
              • Control circuit type
                AC at 50/60 Hz
                [Uc] control circuit voltage
                220 V AC 50/60 Hz
                Auxiliary contact composition
                1 NO + 1 NC
                [Uimp] rated impulse withstand voltage
                8 kV conforming to IEC 60947
                Overvoltage category
                III
                [Ith] conventional free air thermal current
                200 A (at 60 °C) for power circuit
                Irms rated making capacity
              • 140 A AC for signalling circuit conforming to IEC 60947-5-1
              • 250 A DC for signalling circuit conforming to IEC 60947-5-1
              • 1660 A at 440 V for power circuit conforming to IEC 60947
                • Rated breaking capacity
                  1400 A at 440 V for power circuit conforming to IEC 60947
                  [Icw] rated short-time withstand current
                • 250 A 40 °C - 10 min for power circuit
                • 580 A 40 °C - 1 min for power circuit
                • 1200 A 40 °C - 10 s for power circuit
                • 1400 A 40 °C - 1 s for power circuit
                • 100 A - 1 s for signalling circuit
                • 120 A - 500 ms for signalling circuit
                • 140 A - 100 ms for signalling circuit
                  • Associated fuse rating
                  • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                  • 315 A gG at <= 690 V coordination type 1 for power circuit
                  • 250 A gG at <= 690 V coordination type 2 for power circuit
                    • Average impedance
                      0.6 mOhm - Ith 200 A 50 Hz for power circuit
                      [Ui] rated insulation voltage
                    • power circuit: 600 V CSA certified
                    • power circuit: 600 V UL certified
                    • power circuit: 1000 V conforming to IEC 60947-4-1
                    • signalling circuit: 690 V conforming to IEC 60947-1
                    • signalling circuit: 600 V CSA certified
                    • signalling circuit: 600 V UL certified
                      • Electrical durability
                      • 0.85 Mcycles 150 A AC-3 at Ue <= 440 V
                      • 1 Mcycles 200 A AC-1 at Ue <= 440 V
                        • Power dissipation per pole
                        • 24 W AC-1
                        • 13.5 W AC-3
                          • Protective cover
                            with
                            Mounting support
                          • rail
                          • plate
                            • Standards
                            • CSA C22.2 No 14
                            • EN 60947-4-1
                            • EN 60947-5-1
                            • IEC 60947-4-1
                            • IEC 60947-5-1
                            • UL 508
                              • Product certifications
                              • LROS (Lloyds register of shipping)
                              • BV
                              • RINA
                              • CCC
                              • GL
                              • UL
                              • GOST
                              • CSA
                              • DNV
                                • Connections - terminals
                                  control circuit: lugs-ring terminals (external diameter: 8 mm)
                                  Tightening torque
                                • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
                                • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
                                • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
                                • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
                                  • Operating time
                                  • 20...35 ms closing
                                  • 40...75 ms opening
                                    • Safety reliability level
                                    • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                    • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                      • Mechanical durability
                                        8 Mcycles
                                        Maximum operating rate
                                        1200 cyc/h 60 °C
                                        Coil technology
                                        built-in bidirectional peak limiting diode suppressor
                                        Inrush power in VA
                                      • 280-350 VA 60 Hz cos phi 0.9 (at 20 °C)
                                      • 280-350 VA 50 Hz cos phi 0.9 (at 20 °C)
                                        • Hold-in power consumption in VA
                                        • 2-18 VA 60 Hz cos phi 0.9 (at 20 °C)
                                        • 2-18 VA 50 Hz cos phi 0.9 (at 20 °C)
                                          • Heat dissipation
                                            3-4.5 W at 50/60 Hz
                                            Auxiliary contacts type
                                          • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                          • type mirror contact 1 NC conforming to IEC 60947-4-1
                                            • Signalling circuit frequency
                                              25...400 Hz
                                              Minimum switching current
                                              5 mA for signalling circuit
                                              Minimum switching voltage
                                              17 V for signalling circuit
                                              Non-overlap time
                                            • 1.5 ms on de-energisation between NC and NO contact
                                            • 1.5 ms on energisation between NC and NO contact
                                              • Insulation resistance
                                                > 10 MOhm for signalling circuit
                                                Contact compatibility
                                                M13
                                                Compatibility code
                                                LC1D
                                                IP degree of protection
                                                IP20 front face conforming to IEC 60529
                                                Protective treatment
                                                TH conforming to IEC 60068-2-30
                                                Pollution degree
                                                3
                                                Ambient air temperature for storage
                                                -60-80 °C
                                                Operating altitude
                                                3000 m without derating
                                                Fire resistance
                                                850 °C conforming to IEC 60695-2-1
                                                Flame retardance
                                                V1 conforming to UL 94
                                                Mechanical robustness
                                              • vibrations contactor open: 2 Gn, 5...300 Hz
                                              • vibrations contactor closed: 4 Gn, 5...300 Hz
                                              • shocks contactor closed: 15 Gn for 11 ms
                                              • shocks contactor open: 6 Gn for 11 ms
                                                • Height
                                                  158 mm
                                                  Width
                                                  120 mm
                                                  Depth
                                                  136 mm
                                                  Net weight
                                                  2.5 kg
                                                  Unit Type of Package 1
                                                  PCE
                                                  Number of Units in Package 1
                                                  1
                                                  Package 1 Weight
                                                  2.2 kg
                                                  Package 1 Height
                                                  18.8 cm
                                                  Package 1 width
                                                  20.8 cm
                                                  Package 1 Length
                                                  17 cm
                                                  Unit Type of Package 2
                                                  P06
                                                  Number of Units in Package 2
                                                  27
                                                  Package 2 Weight
                                                  72.56 kg
                                                  Package 2 Height
                                                  80 cm
                                                  Package 2 width
                                                  80 cm
                                                  Package 2 Length
                                                  60 cm
                                                  Sustainable offer status
                                                  Green Premium product
                                                  EU RoHS Directive
                                                  Compliant
                                                  Mercury free
                                                  Yes
                                                  RoHS exemption information
                                                  Yes
                                                  China RoHS Regulation
                                                  Product out of China RoHS scope. Substance declaration for your information
                                                  Environmental Disclosure
                                                  ENVPEP060301EN
                                                  Circularity Profile
                                                  ENVEOLI100405EN
                                                  WEEE
                                                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                                  PVC free
                                                  Yes
                                                  California proposition 65
                                                  WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
                                                  Warranty
                                                  18 months

                                                  Documents & downloads

                                                  hide show
                                                  Filter items
                                                  • All

                                                  • CAD Files and Packs

                                                  • Product Brochures

                                                  • Technical Data Catalogues

                                                  • Installation Instruction

                                                  • Product Environmental

                                                  • End of Life Manual

                                                  • Data Bulletin

                                                  • Certificates (MSDS)

                                                  • Declaration of Conformity

                                                  Frequently Asked Questions

                                                  hide show

                                                  What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                  Issue:
                                                  Identifying maximum voltage of an LC1D contactor

                                                  Product Line:
                                                  TeSys D Contactors

                                                  Environment:
                                                  IEC contactors and starters used in North America

                                                  Cause:
                                                  n/a

                                                  Resolution:
                                                  IThe maximum voltage per UL and CSA is 600VAC. 
                                                   

                                                  What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                                  Issue:
                                                  Identifying replacement coils for tesys D non-reversing and reversing conactors

                                                  Product Line:
                                                  IEC Contactors and Starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Replacement coil is needed

                                                  Resolution:
                                                  DC replacement coils are not available.
                                                  AC Coils are 50/60 hertz for voltages as listed below:

                                                  Volts - Part Number
                                                  12 ____ LXD1J7
                                                  21 ____ LXD1Z7
                                                  24 ____ LXD1B7
                                                  32 ____ LXD1C7
                                                  36 ____ LXD1CC7
                                                  42 ____ LXD1D7
                                                  48 ____ LXD1E7
                                                  60 ____ LXD1EE7
                                                  100 ___ LXD1K7 ( never brought to North America )
                                                  110 ___ LXD1F7
                                                  115 ___ LXD1FE7
                                                  120 ___ LXD1G7
                                                  127 ___ LXD1FC7
                                                  200 ___ LXD1L7
                                                  208 ___ LXD1LE7
                                                  220 ___ LXD1M7
                                                  230 ___ LXD1P7
                                                  240 ___ LXD1U7
                                                  277 ___ LXD1W7
                                                  380 ___ LXD1Q7
                                                  400 ___ LXD1V7
                                                  415 ___ LXD1N7
                                                  440 ___ LXD1R7
                                                  480 ___ LXD1T7
                                                  575 ___ LXD1SC7
                                                  600 ___ LXD1X7
                                                  690 ___ LXD1Y7


                                                  Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                                  Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                                  Issue:
                                                  Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                                  Product Line: 
                                                  Tesys D Contactors

                                                  Environment:
                                                  IEC contactors

                                                  Resolution:
                                                  The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                                   

                                                  What is the difference between the LC1D1506N7 and the LC1D150N7?

                                                  The LC1D1506N7 can accept 5X25mm Bars aswell as Lugs or ring terminals. The LC1D150N7 only accepts cable lugs upto 120mm2.

                                                  What is the altitude derating for a TeSys D-Line contactor?

                                                  Issue:​
                                                  What is the altitude derating for a TeSys D-Line contactor?

                                                  Product Line:
                                                  Digest 177 Section 18 : Contactors and Starters, IEC

                                                  Environment:
                                                  North American Products

                                                  Resolution:
                                                  The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                                  Voltage
                                                  3500m x 0.90
                                                  4000m x 0.80
                                                  4500m x 0.70
                                                  5000m x 0.60

                                                  Current
                                                  3500m x 0.92
                                                  4000m x 0.90
                                                  4500m x 0.88
                                                  5000m x 0.86

                                                  For example, an LC1D80 at 5000 meters:
                                                  - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                                  - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                                   

                                                  What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                                  Issue:
                                                  Identifying power terminal lug data for the D2 style contactors

                                                  Product Line:
                                                  Tesys D line contactors

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Power terminal lug data required

                                                  Resolution:
                                                  For contactors with screw clamp terminals:
                                                  stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                                  stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                                  solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                                  What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                                  Issue:
                                                  Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                                  Product Line:
                                                  NEMA combination starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Resolution:
                                                  For contactors with screw clamp terminals:
                                                  stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                                  stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                                  solid cable: One or Two #18-8 AWG per terminal.

                                                  What is difference between LC1D50U7 and LC1D50AU7?

                                                  Following are the differences between the LC1D50U7 and the LC1D50AU7:

                                                  LC1D50AU7 has everlink terminals.
                                                  LC1D50AU7....is slightly larger case and accommodate LRD3XX overloads
                                                  Whereas
                                                  LC1D50U7 contactors accommodate LRD33XX overloads.

                                                   

                                                  Do the Everlink reversing contactors come with electrical interlocking?

                                                  Issue:
                                                  Looking for electrical interlock kit for the LC1D65A Everlnk contactors

                                                  Product line:
                                                  Tesys D LC1D40A, LC1D50A, LC1D65A

                                                  Environment:
                                                  Everlink, all voltage codes

                                                  Cause:
                                                  Old D2 version offered an electrical interlock kit

                                                  Resolution:
                                                  The current Everlink version does not offer an electrical interlock kit.  The customer can wire electrical interlocking using the normally closed contacts provided on the contactor.

                                                  Looking for a LC1D50A.. with a 240v coil

                                                   Part code is LC1D50AU7

                                                  What is part number for terminal shrouds for LC1D1506U7?

                                                  The part number for terminal shrouds for LC1D1506 and LC1D1156 contactors is LA9D115703
                                                  User-added image

                                                  LA9D115703

                                                  Shrouds - for 3 poles TeSys model D

                                                  For furher information see:
                                                  https://www.schneider-electric.com.au/en/product/LA9D115703/shrouds---for-3-poles-tesys-model-d

                                                   

                                                  What is the part number for spare contact set for LC1D1506 contactor?

                                                  The part number for spare contact set for LC1D1506 contactor is LA5D150803.

                                                  LA5D150803 
                                                  contacts set LA5-D - 3 poles - for LC1-D150
                                                  For more information see:https://www.schneider-electric.com.au/en/product-range-selector/664-tesys-d?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecat%2Fbrowse.do%3Fconf%3Dnull%26el_typ%3Dproduct%26range_id%3D664%26prd_id%3DLA5D150803%26scp_id%3DAU_en