LC1D115gp TeSys
TeSys LC1D115 or LC1D150 contactor, 3 poles, screw clamp terminals or lugs, with cover, 115A or 150A
LC1D115gp TeSys
TeSys LC1D115 or LC1D150 contactor, 3 poles, screw clamp terminals or lugs, with cover, 115A or 150A

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 115A, 220 VDC, Standard Coil

Catalogue Number: LC1D1156MD
LC1D115gp TeSys
TeSys LC1D115 or LC1D150 contactor, 3 poles, screw clamp terminals or lugs, with cover, 115A or 150A
LC1D115gp TeSys
TeSys LC1D115 or LC1D150 contactor, 3 poles, screw clamp terminals or lugs, with cover, 115A or 150A
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
  • resistive load
  • motor control
    • Utilisation category
    • AC-1
    • AC-3
    • AC-4
      • Poles description
        3P
        Pole contact composition
        3 NO
        [Ue] rated operational voltage
      • power circuit: <= 1000 V AC 25...400 Hz
      • power circuit: <= 300 V DC
        • [Ie] rated operational current
        • 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
        • 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
          • Motor power kW
          • 30 kW at 220...230 V AC 50/60 Hz (AC-3)
          • 55 kW at 380...400 V AC 50/60 Hz (AC-3)
          • 59 kW at 415...440 V AC 50/60 Hz (AC-3)
          • 75 kW at 500 V AC 50/60 Hz (AC-3)
          • 80 kW at 660...690 V AC 50/60 Hz (AC-3)
          • 65 kW at 1000 V AC 50/60 Hz (AC-3)
          • 18.5 kW at 400 V AC 50/60 Hz (AC-4)
            • Motor power hp
            • 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
            • 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
            • 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
            • 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
              • Control circuit type
                DC standard
                [Uc] control circuit voltage
                220 V DC
                Auxiliary contact composition
                1 NO + 1 NC
                [Uimp] rated impulse withstand voltage
                8 kV conforming to IEC 60947
                Overvoltage category
                III
                [Ith] conventional free air thermal current
                200 A (at 60 °C) for power circuit
                Irms rated making capacity
              • 1260 A at 440 V for power circuit conforming to IEC 60947
              • 140 A AC for signalling circuit conforming to IEC 60947-5-1
              • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                • Rated breaking capacity
                  1100 A at 440 V for power circuit conforming to IEC 60947
                  [Icw] rated short-time withstand current
                • 250 A 40 °C - 10 min for power circuit
                • 550 A 40 °C - 1 min for power circuit
                • 950 A 40 °C - 10 s for power circuit
                • 1100 A 40 °C - 1 s for power circuit
                • 100 A - 1 s for signalling circuit
                • 120 A - 500 ms for signalling circuit
                • 140 A - 100 ms for signalling circuit
                  • Associated fuse rating
                  • 250 A gG at <= 690 V coordination type 1 for power circuit
                  • 200 A gG at <= 690 V coordination type 2 for power circuit
                  • 10 A gG for signalling circuit
                    • Average impedance
                      0.6 mOhm - Ith 200 A 50 Hz for power circuit
                      [Ui] rated insulation voltage
                    • power circuit: 600 V CSA certified
                    • power circuit: 600 V UL certified
                    • power circuit: 1000 V conforming to IEC 60947-4-1
                    • signalling circuit: 690 V conforming to IEC 60947-1
                    • signalling circuit: 600 V CSA certified
                    • signalling circuit: 600 V UL certified
                      • Electrical durability
                      • 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
                      • 0.95 Mcycles 115 A AC-3 at Ue <= 440 V
                        • Power dissipation per pole
                        • 24 W AC-1
                        • 7.9 W AC-3
                          • Protective cover
                            with
                            Mounting support
                          • plate
                          • rail
                            • Standards
                            • CSA C22.2 No 14
                            • EN 60947-4-1
                            • EN 60947-5-1
                            • IEC 60947-4-1
                            • IEC 60947-5-1
                            • UL 508
                              • Product certifications
                              • GL
                              • LROS (Lloyds register of shipping)
                              • DNV
                              • UL
                              • RINA
                              • GOST
                              • BV
                              • CCC
                              • CSA
                                • Connections - terminals
                                • control circuit: lugs-ring terminals (external diameter: 8 mm)
                                • power circuit: lugs-ring terminals (external diameter: 25 mm)
                                • power circuit: bars 1 cable(s) - busbar cross section: 5 x 25 mm
                                  • Tightening torque
                                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
                                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
                                  • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
                                  • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
                                    • Operating time
                                    • 20...35 ms closing
                                    • 40...75 ms opening
                                      • Safety reliability level
                                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                        • Mechanical durability
                                          8 Mcycles
                                          Maximum operating rate
                                          1200 cyc/h 60 °C
                                          Coil technology
                                          with integral suppression device
                                          Control circuit voltage limits
                                        • operational: 0.75...1.2 Uc DC (at 55 °C)
                                        • drop-out: 0.15...0.4 Uc DC (at 55 °C)
                                          • Time constant
                                            25 ms
                                            Inrush power in W
                                            270-365 W (at 20 °C)
                                            Hold-in power consumption in W
                                            2.4-5.1 W at 20 °C
                                            Auxiliary contacts type
                                          • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                          • type mirror contact 1 NC conforming to IEC 60947-4-1
                                            • Signalling circuit frequency
                                              25...400 Hz
                                              Minimum switching current
                                              5 mA for signalling circuit
                                              Minimum switching voltage
                                              17 V for signalling circuit
                                              Non-overlap time
                                            • 1.5 ms on de-energisation between NC and NO contact
                                            • 1.5 ms on energisation between NC and NO contact
                                              • Insulation resistance
                                                > 10 MOhm for signalling circuit
                                                Contact compatibility
                                                M10
                                                Compatibility code
                                                LC1D
                                                IP degree of protection
                                                IP20 front face conforming to IEC 60529
                                                Protective treatment
                                                TH conforming to IEC 60068-2-30
                                                Pollution degree
                                                3
                                                Ambient air temperature for operation
                                                -5-60 °C
                                                Ambient air temperature for storage
                                                -60-80 °C
                                                Permissible ambient air temperature around the device
                                                -40-70 °C at Uc
                                                Operating altitude
                                                3000 m without
                                                Fire resistance
                                                850 °C conforming to IEC 60695-2-1
                                                Flame retardance
                                                V1 conforming to UL 94
                                                Mechanical robustness
                                              • vibrations contactor open: 2 Gn, 5...300 Hz
                                              • vibrations contactor closed: 4 Gn, 5...300 Hz
                                              • shocks contactor closed: 15 Gn for 11 ms
                                              • shocks contactor open: 6 Gn for 11 ms
                                                • Height
                                                  158 mm
                                                  Width
                                                  120 mm
                                                  Depth
                                                  136 mm
                                                  Net weight
                                                  2.5 kg
                                                  Sustainable offer status
                                                  Green Premium product
                                                  REACh Regulation
                                                  Free of Substances of Very High Concern above the threshold
                                                  EU RoHS Directive
                                                  Compliant
                                                  Mercury free
                                                  Yes
                                                  RoHS exemption information
                                                  Yes
                                                  China RoHS Regulation
                                                  Product out of China RoHS scope. Substance declaration for your information
                                                  Environmental Disclosure
                                                  ENVPEP060301EN
                                                  Circularity Profile
                                                  ENVEOLI100405
                                                  WEEE
                                                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                                  Warranty
                                                  18 months

                                                  Documents & downloads

                                                  hide show
                                                  Filter items
                                                  • All

                                                  • CAD Files and Packs

                                                  • Product Brochures

                                                  • Technical Data Catalogues

                                                  • End of Life Manual

                                                  • Installation Instruction

                                                  • Product Environmental

                                                  • Certificates (MSDS)

                                                  • Declaration of Conformity

                                                  Frequently Asked Questions

                                                  hide show

                                                  What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                  Issue:
                                                  Identifying maximum voltage of an LC1D contactor

                                                  Product Line:
                                                  TeSys D Contactors

                                                  Environment:
                                                  IEC contactors and starters used in North America

                                                  Cause:
                                                  n/a

                                                  Resolution:
                                                  IThe maximum voltage per UL and CSA is 600VAC. 
                                                   

                                                  What is the difference between LC1D115 and LC1D1156?

                                                  The 6 in LC1D1156.. is that the 6 denotes lug bar terminals. Use LC1D115.. for cable connections.


                                                   

                                                  What is the terminal shroud part number for a LC1D1156**

                                                  The part code is LA9D115703

                                                  Does the LC1D1156U7 come with 1NO & 1NC Aux contact

                                                  Yes - all the D range contactors have one of each aux contact

                                                  What is the part number for the 415V AC Coil for the LC1D1156 Contactor?

                                                  The part number for the 415V AC Coil for the LC1D1156 Contactor is "LX1D8N7"

                                                  https://www.schneider-electric.com.au/en/search/lx1d8n7


                                                   

                                                  What is the interlock to use with the lcd1156**

                                                   The interlock is LA9D11502

                                                  Are the D-Line contactors rated to break DC voltages?

                                                  Issue: 
                                                  Can the TeSys D line be used to control DC loads? 

                                                  Product Line:
                                                  Tesys D contactors

                                                  Environment:
                                                  Products sold and used in the United States
                                                   
                                                  Cause:
                                                   DC power circuit
                                                   
                                                  Resolution:
                                                   
                                                  Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                                  Devices are suitable but not UL Listed for DC applications.

                                                  More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                                   

                                                  What are the coil voltage codes for the LC1D115 / LC2D115 and LC1D150 / LC2D150 TeSys contactor?

                                                  Issue:
                                                  LC1D115 / LC2D115 and LC1D150 / LC2D150

                                                  Product Line:
                                                  Tesys D line Contactors

                                                  Environment:
                                                  North America

                                                  Resolution:
                                                  The following list the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

                                                  Note 1: LC1D150 contactors are only available with *7 coil codes.
                                                  Note 2: Coil Code ending number represents frequency rating as follows:
                                                  5 = 50 Hertz
                                                  6 = 60 Hertz
                                                  7 = 50/60 Hertz

                                                  AC Volts ___Code                DC Volts ___Code
                                                  24 ___ B5 or B6 or B7          12 ___ Not Avail.        
                                                  42 ___ D5 or D7                   24 ___ BD
                                                  48 ___ E5 or E6 or E7          36 ___ CD
                                                  110 ___ F5 or F6 or F7         48 ___ ED
                                                  115 ___ FE5 or FE7             60 ___ ND
                                                  120 ___ G6 or G7                72 ___ SD
                                                  127 ___ FC5 or FC7            110 ___ FD
                                                  208 ___ L6 or LE7               125 ___ GD
                                                  220 ___ M5 or M6 or M7       220 ___ MD
                                                  230 ___ P5 or P7                 250 ___ UD
                                                  240 ___ U5 or U6 or U7        440 ___ RD
                                                  277 ___ W6 or UE7                
                                                  380 ___ Q5 or Q6 or Q7                
                                                  400 ___ V5 or V7                
                                                  415 ___ N5 or N7                
                                                  440 ___ R5 or R6 or R7                
                                                  480 ___ T6 or T7                
                                                  500 ___ S5 or S7                


                                                   

                                                  What is the code for a contactor rated at 100A AC3 with a 240V AC coil ?

                                                  Code = LC1D1156U7 ( 3 Pole Contactor comes with 1 N/C + 1 N/O Auxilliary as a standard ) 

                                                  What is the difference between LA9D11569 and LA9D115691?

                                                  Issue:
                                                  Identifying differences between two part numbers

                                                  Product Line:
                                                  IEC contactors and starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Selecting between two similar part numbers

                                                  Resolution:
                                                  LA9D11569 is a set of power connections. LA9D115691 is the bottom connector only as shown on page 16-9 of Digest 173 for the LC1D115 and LC1D150 contactor.


                                                   

                                                  What is the 85A Overload to suit LC1D115* Contactor

                                                  85A Overload code for LC1D115* Contactor = LRD4365 

                                                  What is the difference between the LC1D1506N7 and the LC1D150N7?

                                                  The LC1D1506N7 can accept 5X25mm Bars aswell as Lugs or ring terminals. The LC1D150N7 only accepts cable lugs upto 120mm2.
                                                  Show More